Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"VAV system"”
-
Integrated demand control ventilation for single duct VAV system with terminal reheat
… greatly influences the zone ventilation rate and system energy consumption. In this dissertation, an innovative IDCV method is proposed, which studied the annual system energy consumption and indoor air quality in terms of zone CO2 through simulation. Field experiment was conducted as well to …
-
Inomhusklimat och tekniska lösningar för bostadsenheter offshore-Inriktning mot CAV- och VAV-system
… eller byggnadsverket utan på klimat och systemval. För bostadsdelen i offshoreinstallationer kan följande inomhusklimatparametrar identifieras som avgörande vid projektering: Operativ temperatur Inblåsningstemperatur Luftflöde Vertikala temperaturdifferenser
-
Utformning och drift av ventilationen i en förskola. En jämförelse mellan CAV och VAV-system.
… mot nya mer energieffektiva system. Att välja en viss typ ventilationssystem är däremot inte alltid ett enkelt beslut då det finns ett flertal olika principer av system man kan utgå ifrån för att ventilera en lokal och skapa ett bra inneklimat. De enklaste ventilationssystemen …
-
Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics
Single Duct Variable Air Volume (SDVAV) systems use series and parallel Fan Powered Terminal Units to control the air flow in conditioned spaces. This research developed a laboratory verified model of SDVAV systems that used series and parallel fan terminal units where the fan speeds were …
-
Investigating the Integration of Novel Economizer Damper Control Strategy with DCV and Duct Static Pressure Set Point Reset for VAV System
… consumption is attributed to building mechanical systems, particularly air handling units. Air handling units are a crucial component responsible for distributing conditioned air throughout the building. The supply and return fans within these units play a key role in air circulation and are …
-
Optimal Design and Control of Dual VAV Systems to Achieve Building Energy Efficiency
… ventilation, and air conditioning (HVAC) systems consume the largest quantity of energy. Therefore, energy efficiency in these systems has become a prime objective for building standards and energy policies. The variable air volume (VAV) systems that are the most commonly used HVAC systems …
-
A microprocessor data acquisition system for control of a variable-air-volume air conditioning system
… distributed data acquisition system. The data acquisition system is used in the modification of a variable-airvolume (vAv) system. This VAv system occupies a medium size four story office building located at the Knoxville Utilities Board Middlebrook Pike site.</p><p>A direct …
-
A study of energy usage in a variable air volume HVAC system
… building energy consumption mainly on the HVAC system supply fan energy consumption and building reheat energy. HVAC system for a building often operates using either Constant Air Vo1ume (CAV) system or Variable Air Volume (VAV) system. The CAV system supplies a constant amount of air into each …
-
Digital control for an existing variable-air-volume air handling system
… the modifications to a variable-air-volume (VAV) system designed to improve the system efficiency. An improved control strategy is applied using direct digital control. The system operates in a medium-size office building (85,000 ft.<sup>2</sup> ) and is used only for cooling. The original …
-
Dynamic modeling and global optimal operation of multizone variable air volume HVAC systems
… and Air-Conditioning (HVAC) and building systems. The study on optimal operation as well as modeling of HVAC and building systems is one of the fastest growing fields that contribute to saving energy and improving indoor environment. This thesis is devoted to the development of a …
-
Heating, ventilation and air conditioning system optimization: a study of the effect of climate, building design, system selection and control strategy on the energy consumption of a typical office building in London and Athens.
… heating, ventilation and air conditioning (HVAC) system. The thesis studies the effect of a number of building and HVAC system related design factors on the energy performance of a notional air-conditioned office building employing either a variable air volume (VAV) system with terminal …
-
Heating, ventilation and air conditioning system optimization: a study of the effect of climate, building design, system selection and control strategy on the energy consumption of a typical office building in London and Athens
… heating, ventilation and air conditioning (HVAC) system. The thesis studies the effect of a number of building and HVAC system related design factors on the energy performance o f a notional air-conditioned office building employing either a variable air volume (VAV) system with terminal …
-
Robust neural network controller for variable airflow volume system
… controller for the Variable Airflow Volume (VAV) system. A robust weight-tuning algorithm is proposed to train the multi-layered NN with a dead zone scheme. This scheme assures the convergence of the NN tracking error in the presence of disturbance.
-
Dynamic performance of control loops and their interactions in a VAV HVAC system
… occupant comfort. During the last 10 years, VAV-HVAC systems are widely used in commercial buildings because they can reduce energy use significantly and provide good temperature control of the conditioned spaces compared to CV-HVAC systems. However, the controls for VAV systems are somewhat …
-
Design of Active Chilled Beam systems: Detailed economic analyses for different design temperatures and airflows
The predominant space-cooling system prevailing in Swedish commercial buildings today is the variable air volume (VAV) system. The system efficiently modulates the supplied air volume to meet changing cooling demands. An alternative cooling system is active chilled beams (ACB). ACB is a …
-
Online adaptive and intelligent control strategies for multizone VAV systems
… energy used in buildings is consumed by HVAC systems. With escalating cost of energy, several energy efficiency strategies have been implemented in buildings. Among these, the use of VAV systems, and improved method of controlling such systems have received greater attention. This thesis is …
-
Investigation of a Radiantly Heated and Cooled Office with an Integrated Desiccant Ventilation Unit
… and cooling is the most recently developed system. This dissertation provides a comprehensive study of several technical issues relative to radiant heating and cooling systems that have received little attention in previous research. The following aspects are covered in this dissertation: …
-
VARIABLE AIR VOLUME AND CONSTANT AIR VOLUME AIR?CONDITIONING SYSTEMS IN SINGAPORE
… comfort level has made the preference for the VAV system over the CAV (Constant Air Volume) system questionable, and a significant number of building owners are considering or are already in the process of reverting to the CAV system in the air-conditioning design for their new buildings. This …
-
THERMAL COMFORT LEVELS AND ENERGY EFFICIENCY: STUDIES WITH AN INTEGRATED CONTROL SYSTEM
… design of controllers for Variable Air Volume (VAV) system by manipulating flow rate of air in order to control the air temperature of a room. It explains clearly the steps of controller design from the application of the First Law of Thermodynamics, concerning energy balance of heat in the …
Page 1 of 3