Accurate Tracking of Position and Dose During VMAT Based On VMAT-CT
… is achievable with EPID images acquired during VMAT and was named as VMAT-CT. However, it did not gain popularity due to multiple limitations and technical challenges. The goal of this study was to extend VMAT-CT concept, generate complete 3D or 4D CT images and dose, track and adapt VMAT plan …
-
VMAT Collimator Angle Optimization
… collimator angle can be determined for each VMAT control point. Eclipse was used as the treatment planning system and results were validated with professional dosimetrist plans. Results: Generating an optimized collimator angle solution within Eclipse is too time consuming to be clinically …
-
4D-VMAT dose calculation using treatment-specific respiratory motions
… such as volumetric modulated arc therapy (VMAT) could contribute to differences between planned and delivered radiation dose distributions. The purpose of this work was to develop and experimentally validate a method to calculate the VMAT dose distribution in 4-dimensions (4D-VMAT dose …
-
Constrained marker-based VMAT plan optimization towards real-time tumour tracking
… of volumetric modulated arc therapy (VMAT) plans using fiducial markers. We propose that by incorporating fiducial marker constraints into the optimization, one may produce treatment plans that ensure a higher visibility of fiducials throughout the irradiation (a requirement for …
-
Enhanced Optimization with VMAT Treatment Plan Delivered Using Varian TrueBeam System
… and AXB calculated distributions. Four Eclipse VMAT TrueBeam HD MLC treatment plans were evaluated (from MC simulation to EO application): two with 6X and two with 6X FFF energies. Results: For homogenous cases, PTV DVH discrepancies between Eclipse and MC distributions are minor, with AXB-MC …
-
Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations
… MU check method for independent verification of VMAT treatment planning system dose calculations, that would be in accordance with TG-114 recommendations. Methods: For a VMAT patient treatment plan created for a Varian Trilogy linac, DICOM information was exported from Eclipse. An open-source …
-
Επιβεβαίωση πλάνου ακτινοθεραπείας Ca προστάτη , με τεχνική VMAT. Σύγκριση τεσσάρων μεθόδων
… είναι η ογκομετρικά διαμορφωμένη ακτινοθεραπεία VMAT, όπου η χορήγηση γίνεται με τοξοειδή τρόπο περιστροφικά του ασθενούς. Η τεχνική VMAT επιτρέπει την χορήγηση υψηλών δόσεων ακτινοβολίας και επιτυγχάνει υψηλή ακρίβεια στον καρκινικό όγκο-στόχο, διατηρώντας παράλληλα διατηρεί την δόση στους …
-
Low History VMAT Monte Carlo Dose Matrix Denoising with Digital Smoothing Filters
… filters for independent verification of VMAT treatment planning system dose calculations. Methods: For a VMAT patient treatment plan created for a TrueBeam linac, DICOM information was exported locally from Eclipse after anonymization. The input files for Monte Carlo simulation were then …
-
Μελέτη του δείκτη γ κατά τον έλεγχο ποιότητας πλάνων IMRT και VMAT
… Therapy, IMRT, Volumetric Modulated Arc Therapy, VMAT), σύμφωνα με το πρωτόκολλο του TG-218, η κλινική συσχέτιση των gamma passing rates (%GP) και η σύγκριση των δισδιάστατων (2D) με τους τρισδιάστατους (3D) %GP κατά την ανίχνευση σφαλμάτων στη δόση. Υλικά και Μέθοδοι: Πραγματοποιήθηκε ο έλεγχος …
-
Volumetric modulated arc therapy (VMAT) : advanced delivery techniques for static and moving targets
Volumetric Modulated Arc Therapy (VMAT) is a rotational radiation therapy which has been used to treat various cancer sites. The continuous delivery of a specific treatment plan for arc therapy can be achieved with multiple solutions for speed of gantry rotation, beam dose rate variation in time …
-
Δημιουργία, εκπαίδευση και εφαρμογή knowledge based planning (KBP) μοντέλων σε VMAT πλάνα ακτινοθεραπείας
… τέσσερα μοντέλα Knowledge-Based Planning (KBP) VMAT πλάνων ακτινοθεραπείας πνεύμονα, διερευνώντας διαφορετικές στρατηγικές εκπαίδευσης ως προς τη διαχείριση outliers και τον αλγόριθμο υπολογισμού δόσης. Σκοπός: Η διερεύνηση της προβλεπτικής ικανότητας των μοντέλων σε νέα περιστατικά και η …
-
An AI-driven, Virtual DVH-Based Patient-Specific QA Framework for Lung SBRT VMAT
… (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic body radiation therapy (SBRT), have significantly improved target conformity and sparing of normal tissue. However, these techniques introduce complexities in dose calculation and delivery, necessitating rigorous …
-
New Methods in Optimization Algorithms and Technology Applied to VMAT and IMRT Inverse Treatment Planning
A TPS produces IMRT and VMAT plans by applying an optimization process to an objective function, followed by an accurate calculation of the final, deliverable dose. We developed two novel methods to optimize these plans. The first method involves using Monte Carlo (MC) routines. MC is considered to …
-
A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films
VMAT therapy considered as one of the new techniques for treating cancer patients. This smart arc therapy decreases the treatment time, which decreases the patient motion and the internal motion of the tumor. This thesis came to study the accuracy of this kind of treatment in heterogenetic region …
-
Study and introduction of knowledge-based planning (KBP) models for VMAT treatment plans into clinical use
… θεραπείας με δέσμες διαμορφούμενης έντασης (VMAT). Πλάνα θεραπείας με διαφορετική συνταγογραφούμενη δόση δεν αναμείχθηκαν στο ίδιο μοντέλο. Τα μοντέλα δημιουργήθηκαν και ονομάστηκαν με βάση την συνταγογραφούμενη δόση στο Planning Target Volume (PTV), ονομαστικά μοντέλο κεφαλής τραχήλου 54 Gy, …
-
Monte Carlo modeling of the Millennium 120-leaf multiLeaf collimator for 3D-CRT, IMRT and VMAT calculations
Σκοπός της παρούσας διπλωματικής εργασίας είναι η πλήρης μοντελοποίηση του Millennium 120-leaf Multileaf Collimator (MLC) χρησιμοποιώντας μεθό- δους προσομοίωσης Monte Carlo (MC). Απώτερος στόχος είναι να διερευνηθεί αν η μοντελοποίηση του MLC μπορεί να χρησιμοποιηθεί για την εξατομικευμένη …
-
Σύγκριση των αλγόριθμων Acuros XB και ΑΑΑ και δοσιμετρική επιβεβαίωση πλάνων θεραπείας με τεχνική VMAT στην Ακτινοθεραπεία
… (Volumetric Modulated Arc Therapy, VMAT), όσον αφορά το δοσιμετρικό τους αποτέλεσμα. Μέθοδος και υλικά: Αρχικά, πραγματοποιήθηκε μελέτη σε ομοιώματα, όπου συγκρίθηκαν οι δόσεις που υπολογίστηκαν από τους δύο αλγόριθμους με αυτές που μετρήθηκαν με ραδιοχρωμικά film, σε ένα ομοιογενές …
-
Monte Carlo techniques for patient specific verification of complex radiation therapy treatments including TBI, VMAT and SBRT lung
… (TBI) and Volumetric modulated arc therapy (VMAT). This work was motivated by an initial study including ten non-small cell lung cancer (NSCLC) patients which evaluated the dosimetric consequences of plans optimized using the treatment planning system (TPS) by recalculating them with MC. It …
-
Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode
… using Volumetric Modulated Arc Therapy (VMAT) using a 10 MV beam in Flattening Filter Free (FFF) mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating …