Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"VMAT plan"”.

  1. Constrained marker-based VMAT plan optimization towards real-time tumour tracking

    … of volumetric modulated arc therapy (VMAT) plans using fiducial markers. We propose that by incorporating fiducial marker constraints into the optimization, one may produce treatment plans that ensure a higher visibility of fiducials throughout the irradiation (a requirement for …

    manitoba Repository record for Constrained marker-based VMAT plan optimization towards real-time tumour tracking (opens in a new tab)

  2. Resolution Adaptation and Secondary Optimization of Volumetric Modulated Arc Therapy

    Volumetric modulated arc therapy (VMAT) combines good radiation dose performance, in terms of target coverage, with increased speed-of-delivery, as compared with competing forms of intensity modulated radiation therapy. A VMAT plan is produced by solving an optimization problem using dose-volume …

    buffalo Repository record for Resolution Adaptation and Secondary Optimization of Volumetric Modulated Arc Therapy (opens in a new tab)

  3. Accurate Tracking of Position and Dose During VMAT Based On VMAT-CT

    … is achievable with EPID images acquired during VMAT and was named as VMAT-CT. However, it did not gain popularity due to multiple limitations and technical challenges. The goal of this study was to extend VMAT-CT concept, generate complete 3D or 4D CT images and dose, track and adapt VMAT plan …

    lsu-thes Repository record for Accurate Tracking of Position and Dose During VMAT Based On VMAT-CT (opens in a new tab)

  4. Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom

    Validation of treatment plan quality and dose calculation accuracy is essential for new radiotherapy techniques, including volumetric modulated arc therapy (VMAT). VMAT delivers intensity modulated radiotherapy treatments while simultaneously rotating the gantry, adding an additional level of …

    uthsc Repository record for Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom (opens in a new tab)

  5. New Methods in Optimization Algorithms and Technology Applied to VMAT and IMRT Inverse Treatment Planning

    A TPS produces IMRT and VMAT plans by applying an optimization process to an objective function, followed by an accurate calculation of the final, deliverable dose. We developed two novel methods to optimize these plans. The first method involves using Monte Carlo (MC) routines. MC is considered to …

    buffalo Repository record for New Methods in Optimization Algorithms and Technology Applied to VMAT and IMRT Inverse Treatment Planning (opens in a new tab)

  6. Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations

    … MU check method for independent verification of VMAT treatment planning system dose calculations, that would be in accordance with TG-114 recommendations. Methods: For a VMAT patient treatment plan created for a Varian Trilogy linac, DICOM information was exported from Eclipse. An open-source …

    buffalo Repository record for Secondary Monitor Unit Checks for VMAT Using Parallelized Monte Carlo Simulations (opens in a new tab)

  7. Cardiac synchronized volumetric modulated arc therapy

    … heart rate. Although real-time treatment plan adaptation is not possible with the current linear accelerator systems, we demonstrated the feasibility of our technique by synchronizing beam delivery with sample ECG data. A conventional VMAT plan was split into 3 interleaved phases – each …

    ubc Repository record for Cardiac synchronized volumetric modulated arc therapy (opens in a new tab) Download PDF for Cardiac synchronized volumetric modulated arc therapy (opens in a new tab)

  8. 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

    … so called volumetric modulated arc therapy (VMAT). Using both gel measurements and Monte Carlo simulations it was successfully demonstrated that the VMAT plan was both accurately calculated and delivered as planned. Additionally, the performance of a tumour-tracking system during VMAT …

    lund Repository record for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab) Download PDF for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab)