Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Vacuum diode"”.
-
Anode material testing in a vacuum diode
… first being a high temperature bake-out under vacuum (10-7 Torr) followed by an ultrasonic cleaning. The second treatment omits the high temperature bake-out. A low impedance Marx generator, with no intermediate pulse forming apparatus, is used to drive the vircator. For all testing, an …
-
The onset of breakdown in a fast pulsed vacuum diode
… mechanism by which plasma forms in a fast pulsed vacuum diode is not yet well understood. The most popular model of the phenomenon is the explosive emission model. Current densities required by the explosive emission model are much larger than can be provided by space charge limited currents. This …
-
Current density limitations in a fast-pulsed high-voltage vacuum diode
… (rise-time = ns), high voltage (> 106 V), 1-inch vacuum diode was conducted using a computer simulation based on the Fowler-Nordheim equation. Oscillations in the emitted current density (due to the change in the amount of space charge within the gap) were found to quickly decay into a final …
-
Laser Assisted Field Emission Dynamics in a Vacuum Diode at Nanosecond Temporal Resolution
… of laser-enhanced field emission within a vacuum diode aiming to understand the superposition influence of a pulsed ultraviolet (UV) laser and DC electric field. The experimental setup features a vacuum diode with parallel capacitors to maintain a static electric field, nanosecond pulsed …
-
Investigation of onset of plasma formation at anode of fast-pulsed high-voltage vacuum diode
… by which plasma forms in a fast pulsed high vacuum diode has been greatly studied. For the most part, efforts have been concentrated on plasma formation at the cathode. Recently, investigators improved the popular explosive emission model, taking into account the ion current density and …
-
Plasma formation on the anode of the Flash X-ray facility
… associated with the formation of plasma in a vacuum diode during the break down process. The issues brought forth in this thesis have been studied for many years but have not yet been well understood. Specifically, on the anode of a fast pulsed high vacuum diode the Explosive Electron Emission …
-
Μελέτη και σχεδίαση κυματοδηγικού vircator
… problems, such as the Child-Langmuir law for the vacuum diode, the formation of virtual cathode in the vacuum triode, in the short-circuited vacuum diode and in electron beams, are examined. Vacuum tube-specific terms, such as electron emission, plasma oscillations, vacuum breakdown and …
-
High resolution simulation of a vacuum microdiode
In this thesis a vacuum microdiode is simulated where each electron in the system is regarded as point charge and observed through the system from Cathode to Anode. A space charge limited emission process is simulated. Low voltage sufficies to create large electric field across the vacuum diode …
-
X-ray pulse considerations and electron flow in high voltage vacuum diodes
Electrical breakdown in high voltage diodes has been studied since the 1920s, yet it is still not well understood. This study characterizes the electron flow during breakdown in a high voltage vacuum diode. This was accomplished by measuring the x rays produced when electrons strike the anode of …
-
High Efficiency Axial Diffraction Output Schemes for the A6 Relativistic Magnetron
… strives for compact and highly efficient vacuum diode-driven sources. MAGIC particle-in-cell (PIC) computer simulations have shown that the performance of the well-known A6 relativistic magnetron with radial power extraction through one or more of its cavities can be improved by instead …
-
Electron-Beam Gun System for Electron-Capture Rate-Coefficient Measurement
… electron-beam is formed by a lead (Pb) cathode vacuum-diode. The resulting electron-beam pulse has an energy of 90KeV per electron, a peak current density at the anode center of 175 A/cm², and a duration of 12 ns (FWHM).</p> <p>The electron-beam is injected through a 26-μm thick aluminum foil …
-
Analytical, Simulation, and Experimental Study of the Generation of Multiple Beams for Application to a Traveling Wave Tube(TWT)
… wave tube (TWT) has been a reliable conventional vacuum electron device (VED) since the 1940s. Researchers, beginning in the late 1980s, extended the TWT to the relativistic electron beam regime to generate 100s MW power in X-band. Since the mid-1990s there has been little advancement in the …
-
Experimental Study of X-ray Production and Implosion Dynamics of Low-, Mid-, and High-Atomic-Number Materials on University-Scale Z-pinch Machines of Various Architecture
… as an absolutely calibrated PCD, filtered Si-diodes, x-ray pinhole cameras, spectrometers, and a fast, visible light camera which captures plasma evolution. In contrast to the Marx bank (which has been in widespread use in pulsed power research for decades), the LTD is a relatively new pulsed …