Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 50 for “"Vacuum systems"”.

  1. Physiological and Mechanical Effects of Prosthetic Elevated Vacuum Systems in People with Transtibial Amputation

    … expediting long-term limb changes. Elevated vacuum (EV) has been used to maintain suspension and manage limb volume by evacuating the air between the prosthetic liner and the socket thus allowing fluid to be drawn into the limb. The physiological and mechanical effects of EV are not well …

    washington Repository record for Physiological and Mechanical Effects of Prosthetic Elevated Vacuum Systems in People with Transtibial Amputation (opens in a new tab)

  2. Study of accumulation of gases in vacuum systems: Measurement of gas transport properties of polymeric films

    … that the resistance to accumulation of gases in vacuum tubes is not always negligible. The process of accumulation was described using the Fick's second law of diffusion. The diffusion coefficient was assumed constant and evaluated, depending on pressure, considering Knudsen diffusion, molecular …

    ottawa-retro Repository record for Study of accumulation of gases in vacuum systems: Measurement of gas transport properties of polymeric films (opens in a new tab)

  3. Multi-level analysis of atomic layer deposition barrier coatings on additively manufactured plastics for high vacuum applications

    … has aided in the development of control systems with a wide variety of uses. Here it is used for the development of an open-source dual axis gimbal system. This system is used to characterize optoelectronic properties of thin transparent films at varying angles. Conventionally, the …

    mtu Repository record for Multi-level analysis of atomic layer deposition barrier coatings on additively manufactured plastics for high vacuum applications (opens in a new tab)

  4. A novel magneto optical trap for integrated atom chips

    … for use in integrated atom chips and other vacuum systems in which optical access is limited to a single window. The trap design relies on the<br/>switching of optical and magnetic fields and can operate at frequencies at least within the region of 1 kHz to 60 kHz. The design does not need …

    soton Download PDF for A novel magneto optical trap for integrated atom chips (opens in a new tab)

  5. Experimental investigations of using silica aerogel to harvest unconcetrated sunlight in a solar thermal receiver

    … heat in this range requires expensive optics or vacuum systems in order to utilize the diluted solar energy flux reaching the earth’s surface. Current flat plate solar collectors have significant heat losses and achieving higher temperatures without using concentrating optics remains a challenge. …

    utc Repository record for Experimental investigations of using silica aerogel to harvest unconcetrated sunlight in a solar thermal receiver (opens in a new tab)

  6. Temperature Calibration and Electrode Preparation for Use in the Study of Ionic Conductivity of AgBr Thin Films

    … are done using oil-diffusion and ion-pumping vacuum systems, respectively. Ionic conductivity measurements are done as a function of temperature for each of the thin films. A series of temperature calibration experiments for the sample holder were done to enable the determination of the …

    marquette Repository record for Temperature Calibration and Electrode Preparation for Use in the Study of Ionic Conductivity of AgBr Thin Films (opens in a new tab)

  7. Effect of the unit operations: evaporation and drying on the whole and skimmed milk powder properties

    … Both the rotary evaporator and freeze dryer used vacuum systems, reducing the boiling point during concentration and aiding water sublimation in low-pressure environments. A total of eight treatments were produced. The study analyzed the chemical composition of liquid milk and powder, as well as …

    brazil-ufv Repository record for Effect of the unit operations: evaporation and drying on the whole and skimmed milk powder properties (opens in a new tab)

  8. A System for Measuring Radiation Induced Chemical Products in Atmospheric Gases Using Optical Detection Methods

    … is followed by a description of the optical and vacuum systems that were available and the modifications required to integrate the optical system into the vacuum chamber to achieve the ability to optically monitor the ozone levels in a controlled atmosphere. Both the ringdown data collection and …

    usm Repository record for A System for Measuring Radiation Induced Chemical Products in Atmospheric Gases Using Optical Detection Methods (opens in a new tab)

  9. Characterization of hematite nanowire arrays synthesized by atmospheric plasma.

    … the sample. Unfortunately, due to the nature of vacuum systems, this process would be difficult to scale-up and as such atmospheric plasma synthesis was explored. Photoactive hematite nanowire arrays were synthesized using an atmospheric microwave plasma jet reactor. They exhibited all of the …

    louisville Repository record for Characterization of hematite nanowire arrays synthesized by atmospheric plasma. (opens in a new tab)

  10. Apparatus for study of ion-thruster propellant ionization

    … After assembling a facility which uses existing vacuum systems and available instrumentation, we manufactured and tested miniature discharge geometries consisting of commercial 2â x2â copper-clad wafers. Three nominal insulator thicknessâ were used, 0.005,â 0.010â and 0.115.â The wafers were each …

    nps Repository record for Apparatus for study of ion-thruster propellant ionization (opens in a new tab)

  11. Copper Electrodeposition in Mesoscale Through-Silicon-Vias

    … 5:1 aspect ratio) will be utilized in ultra-high-vacuum systems and thus require a uniform, void-free Cu deposit of sufficient thickness to prevent device degradation due to skin effects when RF frequencies as high as 100 V at 100 MHz are used. Conformally Cu-lined TSVs are achieved through the …

    unm Repository record for Copper Electrodeposition in Mesoscale Through-Silicon-Vias (opens in a new tab)

  12. Evolution and Regularisation of Vacuum Brill Gravitational Waves in Spherical Polar Coordinates

    … evidence that all IVP formulations of pure vacuum Brill gravitational waves collapse to form singularities/black holes, and we do not observe critical black hole mass scaling phenomena in the IVP parameter phase space that has been characterised in non-vacuum systems. A theoretical framework …

    calgary Repository record for Evolution and Regularisation of Vacuum Brill Gravitational Waves in Spherical Polar Coordinates (opens in a new tab)

  13. Investigation Into Perpendicular Anisotropy Cobalt-chromium Films With Application To Winchester Computer Discs

    … which are commonly present even in high vacuum systems, were intentionally introduced in the sputtering chamber and their effects on both magnetic and crystallographic properties of CoCr were noted . To measure the perpendicular and in-plane magnetic properties of CoCr , a combined …

    plymouth Repository record for Investigation Into Perpendicular Anisotropy Cobalt-chromium Films With Application To Winchester Computer Discs (opens in a new tab)

  14. Design and calibration of a high temperature continuous run electric arc wind tunnel

    … were water cooling and waste disposal systems, air supply and vacuum systems, and electric arc power supply system and control. An examination of tests performed in the electric-arc facility showed that a low density supersonic flow with a stagnation temperature of approximately 10,000 …

    vt Repository record for Design and calibration of a high temperature continuous run electric arc wind tunnel (opens in a new tab)

  15. Fabrication of lanthanide-doped glasses and their possible application as UV detectors

    … detectors. All presently available UV detection systems are extremely expensive and most are unstable to some degree. A number of the lanthanides fluoresce within the spectral response region of commercial photomultiplier tubes and glass is a suitable material for use in vacuum systems. Rare …

    dcu Download PDF for Fabrication of lanthanide-doped glasses and their possible application as UV detectors (opens in a new tab)

  16. Computational and engineering aspects of in situ ellipsometry

    … of an in situ ellipsometer on two different vacuum coating systems is the experimental part of this thesis. As a numerical computational test an algorithm and computer code has been developed for computing, from the'¥ and~ measurements, the thickness (d) and the complex refractive index …

    ucf Repository record for Computational and engineering aspects of in situ ellipsometry (opens in a new tab)

  17. Electrical and optical properties of organic thin films

    … films for these studies. Thermal evaporation in vacuum was used to deposit aluminum as electrodes and contacts in MIS and MIM devices. The organic films were deposited by either thermal evaporation or the Langmuir-Blodgett (L-B) dipping technique. Several vacuum systems and an L-B trough were …

    ttu Repository record for Electrical and optical properties of organic thin films (opens in a new tab)

  18. An experimental apparatus and diagnostics for the study of vacuum surface flashover

    Upper operational limits in pulsed power vacuum systems are typically determined by the maximum electrical stress the apparatus can handle. If this limit is exceeded, the first point in these systems to fail is usually the dielectric interface separating the anode and cathode. This failure is due …

    ttu Repository record for An experimental apparatus and diagnostics for the study of vacuum surface flashover (opens in a new tab)

  19. Low Energy Electron Diffraction Study of Epitaxial Cr2O3(0001) Films Grown on Cr(110)

    … overlayer. Since CO is present in all vacuum systems and itinerate magnetic effects are very unusual, the source of the surface reconstruction is most likely not from a surface magnetic transition but from CO adsorption at low temperatures. It is probable, due to the lower base pressure …

    texas-state Repository record for Low Energy Electron Diffraction Study of Epitaxial Cr2O3(0001) Films Grown on Cr(110) (opens in a new tab)

  20. Energy efficiency analysis of autoclave curing of thermoset composites using simulation

    … multi-step process. It is best analyzed as a systems problem, and any variation in one cell of a factory can propagate through the entire process chain and affect the quality or property outcomes. In this work, a previously developed structured approach that defines Material, Shape, Tooling, …

    ubc Repository record for Energy efficiency analysis of autoclave curing of thermoset composites using simulation (opens in a new tab) Download PDF for Energy efficiency analysis of autoclave curing of thermoset composites using simulation (opens in a new tab)

Page 1 of 3