Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 35 for “"Van Deemter"”

  1. Termoplastik elastomerlerde organik buharların difüzyon katsayılarının belirlenmesi

    … değişimden difüzyon katsayısını belirlemek için Van Deemter eşitliği kullanılmıştır. Elde edilen lineer bağıntı bu çalışma için Van Deemter eşitliğinin uygun olduğunu göstermiştir. Sonsuz seyrelme difüzyon katsayıları artan sıcaklıkla artmış, sonsuz seyrelme aktivite katsayıları artan sıcaklıkla …

    ogu-tr Repository record for Termoplastik elastomerlerde organik buharların difüzyon katsayılarının belirlenmesi (opens in a new tab)

  2. A two-case study of band broadening in liquid chromatography

    … the solute concentration was studied. A modified Van Deemter equation was used to separate the contributions due to slow mass transfer and axial dispersion.</p> <p>In the second study, column efficiency and plate height were calculated for polystyrene (MW: 1.87 x 10<sup>6</sup>) on a silica column …

    ut-knoxville Repository record for A two-case study of band broadening in liquid chromatography (opens in a new tab)

  3. Chromatographic Properties of Silica-Based Monolithic HPLC Columns

    … network (monolith) of porous silica. The main advantage of such a network is decreased backpressure due to macropores (2 μM) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The Chromolith SpeedROD™ (EM …

    vt Repository record for Chromatographic Properties of Silica-Based Monolithic HPLC Columns (opens in a new tab)

  4. Formation, Functionalization, Characterization, and Applications of a Mixed-Mode, Carbon/Diamond-Based, Core-Shell Phase for High Performance Liquid Chromatography

    … crosslinking with epoxides. I have performed van Deemter and van’t Hoff analyses to understand the properties of these columns. Efficiencies greater than 100,000 N/m are routinely achieved with these carbon/nanodiamond-based phases. In addition I contributed to two patents that show …

    byu Repository record for Formation, Functionalization, Characterization, and Applications of a Mixed-Mode, Carbon/Diamond-Based, Core-Shell Phase for High Performance Liquid Chromatography (opens in a new tab)

  5. Characterizing TCAP Set-ups for Effective Separation on Hydrogen Isotope Species

    … in each case. These values were then fit with van Deemter curves to illustrate the change in HETP over gas velocity. A strong positive correlation with temperature was found, as well as a positive correlation with particle size and a weak negative correlation with column diameter.

    rit Repository record for Characterizing TCAP Set-ups for Effective Separation on Hydrogen Isotope Species (opens in a new tab)

  6. Retention Mechanism for Reversed Phase and Hydrophilic Interaction Liquid Chromatography: Development and Characterisation of Modified Silica Particles

    … was shown to be due to a high A Term in the van Deemter equation, due to a high level of Eddy dispersion in the silica bed. SEM imaging of the unpacked TYPE-C™ Bidentate C18 silica material showed a number of irregular particles present, these were identified as amorphous polyhydrosiloxane …

    the-open-u Repository record for Retention Mechanism for Reversed Phase and Hydrophilic Interaction Liquid Chromatography: Development and Characterisation of Modified Silica Particles (opens in a new tab)

  7. Polyimide Polymer Glass-Free Capillary Columns for Gas Chromatography

    … study, a column reproducibility study, and a van Deemter study. The uncoated polyimide columns are minimally capable of GC separations. The coated polyimide columns successfully separate Grob test mix alkanes, bases, and fatty acid methyl esters, and are comparable to standard fused-silica …

    ohiolink Repository record for Polyimide Polymer Glass-Free Capillary Columns for Gas Chromatography (opens in a new tab)

  8. Reversed Phase Liquid Chromatography Using the Ionic Liquid Isopropylammonium Formate and Comparison of Indirect Spectrophotometric Methods for Phosphate

    … and solvent strength are measured. Various van Deemter plots using different mixing approaches of the mobile phase and different columns are compared. The utility of IPAF has been further shown to be a suitable modifier solvent for the separation of cytochrome c from tryptophan. At 50°C, …

    ohiolink Repository record for Reversed Phase Liquid Chromatography Using the Ionic Liquid Isopropylammonium Formate and Comparison of Indirect Spectrophotometric Methods for Phosphate (opens in a new tab)

  9. Development of fast ion chromatography

    … chromatographic efficiency due to the favorable Van Deemter curves obtained as particle size decreases. Using ioninteraction chromatography and direct UV detection, eight anions were separated in under four minutes with the first five anions separated in < 50 seconds; this separation was …

    dcu Repository record for Development of fast ion chromatography (opens in a new tab)

  10. Synthesis and Applications of Monolithic HPLC Columns

    … studied intensely through frontal analysis and Van Deemter plot. Temperature and pressure effects were also investigated in carbon-based columns. The density of bonding on the modified carbon monoliths was characterized by thermogravimetric analysis.</p>

    utk-theses Repository record for Synthesis and Applications of Monolithic HPLC Columns (opens in a new tab)

  11. Development and applications of micellar electrokinetic capillary chromatography

    … efficiency of column parameters were evaluated. Van Deemter type plots were constructed to examine the individual contributions to band broadening in MECC. Column diameter, buffer concentration, applied voltage, and surfactant concentration were studied to elucidate their role in the separation …

    utk-theses Repository record for Development and applications of micellar electrokinetic capillary chromatography (opens in a new tab)

  12. Multiscale analysis of transport in porous media

    … en conditions non-adsorbantes avec le solvant tétrahydrofurane (THF). En mode dynamique, dans l’équation de van Deemter, le terme constant dépend de la diffusion d’eddy et de la polydispersité des polystyrènes. La silice poreuse Si100 présente une distribution de taille des pores assez …

    star-france Repository record for Multiscale analysis of transport in porous media (opens in a new tab)

  13. Analysis of polar compounds by supercritical fluid chromatography

    … by both the columns are also compared. Several van Deemter plots are generated at various constant operating densities and temperatures. Also, the effect of density and temperature on efficiency and resolution is studied for capillary column with split and splitless injection techniques. Several …

    vt Repository record for Analysis of polar compounds by supercritical fluid chromatography (opens in a new tab)

  14. Desenvolvimento e otimização de fases estacionárias monolíticas para eletroforese capilar

    … de 20 segundos. Foi feita também uma curva de Van Deemter, com a qual pôde-se relacionar a influência da voltagem na eficiência de separação das FEM.

    brazil-uff Repository record for Desenvolvimento e otimização de fases estacionárias monolíticas para eletroforese capilar (opens in a new tab)

  15. Ionic Liquids in Micro Extractions and Gas Chromatographic Stationary Phases

    … retention of alkanes and aromatic hydrocarbons. Van’t Hoff plot was made and the thermodynamic parameters ΔG, ΔH, ΔS were determined. The thermodynamic parameters of SLB-IL 59 and SLB-IL 61 were compared with a conventional polyethylene glycol based stationary phase Stabile Wax -10 having similar …

    shu-thes Repository record for Ionic Liquids in Micro Extractions and Gas Chromatographic Stationary Phases (opens in a new tab)

  16. Performance of Nitrogen as a Carrier Gas in Capillary Gas Chromatography Using a Thin Film Column

    … resolution, and efficiency were performed, and Van Deemter curves were created. Nitrogen proved effective and should be considered a reasonable alternative carrier gas in gas chromatography.

    shu-thes Repository record for Performance of Nitrogen as a Carrier Gas in Capillary Gas Chromatography Using a Thin Film Column (opens in a new tab)

  17. An Evaluation Of UHPLC-MS Technology Encompassing Elevated Temperatures, Low Viscosity Operation and Recently Developed Stationary Phase Materials

    … commercially available packings using the Knox/van Deemter and kinetic plots approaches. This work centred on evaluation using realistic test substances on underivatised silica, highlighting that very high efficiencies could be achieved using these phases, otherwise not achievable with …

    kings Repository record for An Evaluation Of UHPLC-MS Technology Encompassing Elevated Temperatures, Low Viscosity Operation and Recently Developed Stationary Phase Materials (opens in a new tab)

  18. Pressure-driven and electroosmotically-driven liquid chromatographic separations in packed fused silica capillaries

    … efficiencies with relatively low pressure drops. Van Deemter plots illustrate the performance characteristics of the columns. Finally, electroosmotic flow is studied as the motive force for liquid chromatographic separations. This combination of two techniques, packed capillary liquid …

    vt Repository record for Pressure-driven and electroosmotically-driven liquid chromatographic separations in packed fused silica capillaries (opens in a new tab)

  19. High performance liquid chromatography-tandem mass spectrometry of pharmaceuticals and personal care products in environmental and biological matrices

    … performance liquid chromatography (HPLC) the advantages of new monolithic stationary phases over traditional particle packed beds is becoming apparent. In this work, the performance of a half-metre monolithic column was characterised using van Deemter plots. The separation efficiency of the …

    dcu Repository record for High performance liquid chromatography-tandem mass spectrometry of pharmaceuticals and personal care products in environmental and biological matrices (opens in a new tab)

Page 1 of 2