Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"Variable compliance"”
-
Passive Variable Compliance for Dynamic Legged Robots
… of designing usefully robust tunable passive compliance into legs has precluded their implementation on practical running robots. In this thesis we present an overview of tunable stiffness legs, and introduce a simple leg model that captures the spatial compliance of our tunable leg. We …
-
A variable compliance controller for cooperative vision guided robotic assembly
… compliant wrist, known as a remote center compliance (RCC) device, to allow the system to accommodate the forces. Using design principles similar to those developed for the RCC, a variable compliance control system is produced in this thesis. This control system allows a dual seven degree …
-
Design and build of artificial blood vessels with variable compliance
… within the circulatory system by mimicking the compliance and therefore recreating physiological flow velocities and pressure waveforms. The compliance of a blood vessel defines how its volume will change in response to a pressure change. This project recreates variable compliance through a …
-
Anthropomorphic adaptation of a mechanically-variable, near-infinite range-of-stiffness mechanism
… and industrial robotics have begun to integrate variable-compliance mechanisms into their systems. Several variable-compliance mechanisms have been designed and tested, but they tend to have low ranges of stiffness and complex designs. A variable-compliance system known as the Adjustable …
-
Compliant polymeric actuators as robot drive units
… actuation systems which use the contractile and variable compliance properties of this material. The stimulation of these fibres is studied (particularly chemical activation using acetone and water), as are the factors which influence the response, especially those relating to its performance as …
-
Laboratory study of the effect of axial compliance on rock penetration of PDC bits
… Bottom-hole Assembly (BHA) configuration (compliance and mass), BHA vibrations, and the Rate of Penetration (ROP). In recent years sophisticated down-hole tools (e.g. shock sub, Thruster, and Flex Stabilizer) have been designed and fabricated to mitigate unwanted BHA vibrations and increase …
-
Design and Validation of a Variable Stiffness Three Degree of Freedom Planar Robot Arm
… and built for proof of concept of a passive variable compliance control strategy that can vary joint stiffness to achieve higher performance dexterous manipulation. This novel planar robot incorporating variable stiffness actuators and common industrial controls allows the robot to comply …
-
Development of a Cardiovascular Simulator Incorporating a Phantom Simulation of the Arterial System
… pulse wave amplification and arterial wall compliance. A synthetic ventricle pump was developed in conjunction with a variable compliance chamber and peripheral resistance. The pump consists of a synthetic ventricle inside a water-filled chamber with a motor actuating a piston to change the …
-
Succesvol sturing geven aan ERP-implementatie: Implementatiesucces voorspellen vanuit naleving van eisen aan governance
… to achieve this success? Does the level of compliance with the standards framework for governance predict the level of success? The following problem statement should answer the above questions: What requirements must be set for the governance process of ERP implementations to achieve …
-
Models Of Infringement:the Commission Of The European Union And Its Relationship With European Union Member States
… is designed to explore the complex question of compliance within the European Union. The European Union relies on the voluntary submission of it members to rules that the organization sets up. Other international organizations operate through this dynamic as well. As such, it is highly important …
-
Design and fabrication of free-standing structures as off-chip interconnects for microsystems packaging
… has been developed which enhances the mechanical compliance of the compliant interconnect without compromising the electrical parasitics. It also provides for redundancy and thus results in more reliable interconnects. Also, to meet both electrical and mechanical performance needs, as part of this …
-
Adherence to STARD 2015 Reporting Recommendations in Pathology
… Two raters independently scored 171 articles for compliance in reporting 34 STARD items. There was excellent inter-rater reliability (Cohen Kappa coefficient = .8773). The mean number of STARD recommended items reported was 15.44 + 3.59 with a range of 4-28 out of maximum possible score of 34. …
-
Cervical Cancer Screening Disparities in an Ethnically Diverse Population of Women Residing in the United States in 1999: A Secondary Analysis of Data from the 1999 Behavioral Risk Factor Surveillance System
… timeframe. Univariate, bivariate and multivariable logistic regression procedures were used to evaluate the association between each one of the independent variables and the dependent variable (compliance with the 1999 cervical screening guidelines of the American Cancer Society). One of …
-
Metamaterial devices
… that, e.g., change their volume, or have variable compliance. While metamaterials were initially understood as materials, we propose to think of them as devices. We argue that thinking of metamaterials as devices enables us to create internal structures that offer functionalities to …
-
An evaluation of stroke rehabilitation within Greater Manchester
… completed questionnaires. Results demonstrated variable compliance to national recommendations with primary stroke centres showing greater adherence than district stroke centres, indicating a two-tier service. All services offered a weekly multidisciplinary team meeting, 93% of patients spent …
-
An evaluation of stroke rehabilitation within Greater Manchester
… completed questionnaires. Results demonstrated variable compliance to national recommendations with primary stroke centres showing greater adherence than district stroke centres, indicating a two-tier service. All services offered a weekly multidisciplinary team meeting, 93% of patients spent …
-
Bayesian Non-linear System Identification and Frequency Response Analysis with Application to Soft Smart Actuators
… e.g. both as actuators and brakes, due their variable compliance. One important class of soft actuator is the dielectric elastomer actuator (DEA). However, DEAs are extremely difficult to control due to their non-linear and time varying dynamics. A crucial step in the advancement of this …
-
Persepsi mahasiswa akuntansi dalam pemilihan karir menjadi praktisi akuntansi syariah: Studi empiris mahasiswa akuntansi angkatan 2011 UIN Maulana Malik Ibrahim Malang
… seen that the ability to explain the independent variable (Perception, Personality, Job Market considerations, Code of Ethics and Social Values ) on the dependent variable (Selection of Islamic Accounting Career Practitioner) by 7.8%, while the remaining 92.2% explained by other variables. Then …
-
MESTRAN, a variable stiffness actuator for energy efficient legged robots
… shock absorbers for legged robots. However, the compliance of those springs is not adjustable and manual assembly is required to make a robot leg stiffer or more compliant. Motivated by this fact, we present a systematic development and evaluation of a new variable compliance/stiffness actuator, …
-
Elastography Characterization and Repeatability in 14 Normal Canine Spleens
… pressure might contribute to the data and this variable was compared between examiners by calculation of the Mann-Whitney U statistic (i.e., Wilcoxon rank-sum test). Strain scores obtained at neutral compression were significantly lower (harder) than maximum compression for both observers …
Page 1 of 2