  1. Retrospective Dosimetric Comparison of MLC Defined Conformal Arc to Stereotactic Cone Plans for Single Fraction SRS on the Varian Edge (TM)

    … currently uses the 2.5mm MLC leaves on our Varian Edge (Varian Medical Systems Inc., Palo Alto, CA) for every SRS case. For most cases the MLCs provide excellent results. However, their unanimous use in the clinic leads to question if they are superior to cones for every case. For small …

    ohiolink Repository record for Retrospective Dosimetric Comparison of MLC Defined Conformal Arc to Stereotactic Cone Plans for Single Fraction SRS on the Varian Edge (TM) (opens in a new tab)

  2. Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy

    … physical cones. The virtual cone therapy, on a Varian Edge™ linac using multiple non-coplanar arcs with static HDMLCs, is a comparable technique that can be used to treat small intracranial neuralgia or other small lesions. In this investigation, two flattening filter free (FFF) photon beams, …

    fau Repository record for Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy (opens in a new tab)

  3. Evaluating the Dosimetric Accuracy of Small Gating Windows in Radiotherapy

    … accepted VMAT plans were delivered using a Varian Edge. The measured dose was compared with the planned dose for five beam-on configurations: 100%, 70%, 50%, 30%, and 20%. A programmable phantom was used to generate the gating signal for 15 BPM in combination with the Varian RPM system. The …

    ohiolink Repository record for Evaluating the Dosimetric Accuracy of Small Gating Windows in Radiotherapy (opens in a new tab)

  4. Implementing Radformation at Personalized Radiation Oncology: Enhancing Efficiency and Precision

    … These lists track results for units such as the Varian Edge, Varian BRAVOS, and Siemens SOMATOM go.Open Pro CT scanner. Ancillary equipment used for testing also has assigned test lists to store calibration factors and receive calibration expiration reminders. The primary goal of utilizing …

    unlv Repository record for Implementing Radformation at Personalized Radiation Oncology: Enhancing Efficiency and Precision (opens in a new tab)

  5. Recommendations for Treatment Planning Dose Indices for Single Target VMAT Brain Stereotactic Radiosurgery/Radiotherapy; A Retrospective Analysis

    … using stereotactic radiosurgery (SRS) on the Edge Radiosurgery System (Varian Medical Systems Inc., Palo Alto, CA) using stereotactic radiosurgery (SRS). This study aims to improve plan quality tolerances for Volumetric-Modulated Arc Therapy (VMAT) by performing a retrospective analysis on …

    ohiolink Repository record for Recommendations for Treatment Planning Dose Indices for Single Target VMAT Brain Stereotactic Radiosurgery/Radiotherapy; A Retrospective Analysis (opens in a new tab)

  6. Comparison of Commercial Pre-Treatment QA Devices for Stereotactic Radiotherapy Plans

    … SNC ArcCheck, IBA Matrixx Resolution, the Varian Edge DMI Electronic Portal Imaging Device, and the IBA myQA SRS detector. The goal of this research is to compare commercial quality assurance devices to the film dosimetry method for pre-treatment evaluation of stereotactic radiosurgery, …

    gatech Repository record for Comparison of Commercial Pre-Treatment QA Devices for Stereotactic Radiotherapy Plans (opens in a new tab)

  7. Characterization of Image Quality between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Clinical Used Protocols in Radiation Therapy Treatment Planning

    … of Toledo Dana cancer center, two CBCT, Varian True Beam OBI CBCT and Varian Edge OBI CBCT, and one FBCT, Philips Gemini TF Big Bore PET/CT, were used for this study. We analyzed image quality using several routine scanning protocols on the three imaging systems. Seven parameters of image …

    ohiolink Repository record for Characterization of Image Quality between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Clinical Used Protocols in Radiation Therapy Treatment Planning (opens in a new tab)

  8. Evaluation of Patient-Scatter Factors for Radiation Therapy ShieldingUsing Physical Measurement in a "Good" Geometry

    … performed for patient-scatter factors for the Varian Edge linear accelerator at all available accelerating potentials for various gantry angles and eld sizes, to compare against NCRP Report No. 151. This allows for validation of the assumptions within NCRP Report No. 151 and comparison to …

    ohiolink Repository record for Evaluation of Patient-Scatter Factors for Radiation Therapy ShieldingUsing Physical Measurement in a "Good" Geometry (opens in a new tab)

  9. A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields.

    … popular TPS's, Pinnacle (Philips) and Eclipse (Varian), were compared, with special emphasis placed on parameterization of the dosimetric leaf gap (DLG) in Eclipse. The DLG is a parameter that accounts for Varian's rounded MLC leaf ends. While Pinnacle accounts for the rounded leaf end by …

    ohiolink Repository record for A Dosimetric Evaluation of The Eclipse and Pinnacle Treatment Planning Systems in Treatment of Vertebral Bodies Using IMRT and VMAT with Modeled and Commissioned Flattening Filter Free (FFF) Fields. (opens in a new tab)

  10. A Novel Equivalent Squares Formalism for use in Small Field Dosimetry

    … Systems (TPS) (Phillps' Pinnacle<sup>3</sup>, Varian's Eclipse, and Raysearch's Raystation), available at the University of Toledo, make use of Output Factors (OF) to characterize machine output as well as to simplify the commissioning process. Each TPS makes use of Equivalent Square Fields …

    ohiolink Repository record for A Novel Equivalent Squares Formalism for use in Small Field Dosimetry (opens in a new tab)

  11. Monte Carlo Modeling of Virtual Multi-Featured Single Photon Source and High-Definition Multileaf Collimator for Modern Medical Linear Accelerators

    … geometries of the Linac head components of our Varian Edge Linac machine. Construction of the high definition multileaf collimator (HD-MLC) was the core work in this part. A total of 120 pieces of leaves of six different types in two opposite position leaf banks were modeled. Each leaf was …

    ohiolink Repository record for Monte Carlo Modeling of Virtual Multi-Featured Single Photon Source and High-Definition Multileaf Collimator for Modern Medical Linear Accelerators (opens in a new tab)

  12. An Investigation into the Accuracy of the Photon Beam Energy Spectrum Modeled by the Pinnacle Treatment Planning System and Its Effects on Treatment Planning

    … 10 MV flattening-filter free (FFF) beams of a Varian Edge linear accelerator using two distinct routes of investigation: first, direct comparison of the Pinnacle3 spectra with those previously published or derived with alternative models, and second, indirect comparison through the inspection …

    ohiolink Repository record for An Investigation into the Accuracy of the Photon Beam Energy Spectrum Modeled by the Pinnacle Treatment Planning System and Its Effects on Treatment Planning (opens in a new tab)

  13. The Limit of Resolution and Detectability of the ArcCHECK QA Phantom in small field Volumetric Modulated Arc Therapy and Stereotactic Radiosurgery Quality Assurance

    … and a dose computed from a 200 MU beam from the Varian Edge linear accelerator (Varian Medical Systems, Palo Alto, CA) at the University of Toledo Dana Cancer Center. Four different types of errors were introduced into quality-assurance analysis procedures. Measured square field sizes were …

    ohiolink Repository record for The Limit of Resolution and Detectability of the ArcCHECK QA Phantom in small field Volumetric Modulated Arc Therapy and Stereotactic Radiosurgery Quality Assurance (opens in a new tab)