Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"Velocity encoding"”.
-
Encoding of saltatory tactile velocity in the adult orofacial somatosensory system
… Closely tied to skilled motor activity, neural velocity encoding mechanisms are crucial for both neurotypical movement production and recovery of function following neurological insult. To date, little is known about tactile velocity encoding in trigeminal networks that process complex cutaneous …
-
Phase unwrapping of 4D-flow MRI data with graph cuts.
A common issue when measuring velocity utilizing 4D flow magnetic resonance imaging (MRI) is aliasing that occurs because of a low velocity encoding parameter (VENC). Aliasing can be avoided if the velocity encoding parameter is set above the largest velocity quantity. However, when this is done …
-
MODELING OF PATIENT-SPECIFIC PERIAORTIC MECHANICS AND PULMONARY ARTERY HEMODYNAMICS BASED ON PHASE-CONTRAST MAGNETIC RESONANCE IMAGING SEQUENCES.
… were implemented as input data, displacement encoding with stimulated echoes (DENSE MRI) applied, and time-resolved velocity encoding phase-contrast MRI, in 1D and 3D, applied to pulmonary artery (PA) hemodynamics. A model to account for the effect of periaortic interactions due to static and …
-
In vivo NMR-methods to study effects of atherosclerosis in mice
… cardiovascular diseases. The aortic pulse wave velocity (PWV) is an indirect measure for vascular stiffness and a marker for cardiovascular risk. Results This work presents three MR-methods that allow the determination of the PWV in the descending murine aorta by analyzing blood flow waveforms, …
-
Untersuchung der Tauglichkeit von Echtzeit Flussmessungen in der Kardialen Magnetresonanztomographie
… gezeigt werden. Methoden: Zwei mit Shared-Velocity-Encoding beschleunigte Echtzeit- Sequenzen wurden mit der konventionellen segmentierten Sequenz verglichen. Die Messungen wurden im Phantom, an Probanden (n=59), an Patienten mit Klappenvitien und Sinusrhythmus (n=55) sowie Vorhofflimmern …
-
Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System
… for the assessment of time‐resolved blood velocity vector fields within arbitrary imaging volumes. Besides velocity vector field information, parameters related to turbulence can be calculated with advanced multi‐point velocity encoding schemes. However, long scan times are currently the …
-
Renal Arterial Blood Flow Quantification by Breath-held Phase-velocity Encoded MRI
… 200 mm FOV. An increase in the number of phase encodings provides improved results, although an increase in image acquisition time is observed. Velocity-encoding in all three orthogonal directions does not improve image data. This method of using MRI to measure flow through a vessel is shown to …
-
Cardiovascular manifestations of Marfan syndrome: insights from advanced cardiovascular magnetic resonance
… magnetic resonance technique with 3-directional velocity encoding (4D flow), demonstrating a high prevalence of major flow disturbance (87 ± 12%), compared to controls (28 ±18%), localising to those regions of the aorta known to be most prone to aortic dissection (sinuses of Valsalva and proximal …
-
Magnetic Resonance Imaging of Cerebral Venous Oxygenation
… technique separates blood signal from tissue by velocity-encoding phase contrast and measures the R2* of pure blood by multi-gradient-echo acquisition. The blood R2* was converted to Yᵥ using an R2*-vs-oxygenation (Y) calibration curve, which was obtained by in vitro bovine blood experiments. …
-
DEVELOPMENT AND CLINICAL TRANSLATION OF MRI METHODS FOR QUANTITATIVE ASSESSMENT OF ORGAN PHYSIOLOGY AND TISSUE STRUCTURE
… Metabolism of Oxygen via T2 and Interleaved Velocity Encoding) was developed for simultaneous measurements of SvO2 and BFR at the renal vein. This work optimized K-MOTIVE to facilitate free-breathing acquisition by increasing its robustness to respiratory motion. Free-breathing K-MOTIVE …
-
Characterising intra-cardiac blood flow patterns in cardiovascular disease using advanced magnetic resonance techniques
… three-dimensional time resolved velocity encoding cardiac magnetic resonance imaging (4D flow).</p> <p>The interactions between intra-cardiac blood flow patterns and cardiovascular disease processes using 4D flow were determined. The relationship between atypical right atrial flow …
-
MRI-Based Quantification of Renal Oxygen Utilization
… the “Metabolism of Oxygen via T2 and Interleaved Velocity Encoding” (MOTIVE) pulse sequence is presented as an advance over existing methods. MOTIVE interleaves a phase-contrast module before a background-suppressed T2-prepared echoplanar imaging readout. T2 is then converted to SvO2 via a …
-
Unraveling Flow-Dynamic Characterization of the Ascending Aorta and Left Ventricle in Bicuspid Aortic Valve Pathologies via 4D Flow MRI
… time-resolved three-dimensional phase-contrast velocity encoding (4D flow MRI), enables comprehensive quantification of blood flow and ventricular energetics, offering the potential for novel biomarkers to improve risk stratification and management. This thesis investigated the ascending aorta …
-
Entwicklung und Analyse von Beschleunigungsmethoden für die funktionelle Untersuchung des kardiovaskulären Systems mit Magnetresonanztomographie
In dieser Arbeit werden Beschleunigungsmethoden für zeitlich aufgelöste MRT-Messungen <br>untersucht und für den Einsatz bei Studien- und Patientenmessungen implementiert. <br>Schwerpunkt sind dabei Anwendungen in der Herz- und Blutgefäßediagnostik. Basis der <br>untersuchten …
-
Rapid Magnetic Resonance Imaging of Tissue Motion with Adaptive Velocity Sensitivity for Evaluating Cardiovascular Function
… has lagged because these techniques suffer from velocity-to-noise ratio (VNR)/aliasing limitations and extended scan time. In this dissertation, we first investigated the possibility of a non-phase-dependent MR velocity mapping method, as such magnitude-dependent methods can address some of the …
-
Optimization and Analysis of The Total Cavo-Pulmonary Connection
… registration of high-resolution PC-MRI velocity vectors to tetrahedral meshes followed by inverse interpolation of the vectors onto the meshes. Detailed flow structures were analyzed. Results show that the new design is more energy efficient than any other idealized models. Furthermore, …
-
Validation of a 1D Algorithm That Measures Pulse Wave Velocity to Estimate Compliance in Blood Vessels
… the new 1D method for measuring pulse wave velocity in the aorta in vivo and estimate compliance. Arterial pressure and blood flow characterize the traveling of blood from the heart to the arterial system and have played a significant role in the evaluation of cardiovascular diseases. Blood …