Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 265 for “"Ventilation systems"”

  1. Low frequency noise in ventilation systems

    <p>The main acoustical problems of Heating, Ventilation and Air-Conditioning systems (HVAC) are found more and more in the low frequency range as silencers and other acoustic methods are generally relatively ineffective in this range. In addition, at low frequencies coupled resonances in the duct …

    soton Repository record for Low frequency noise in ventilation systems (opens in a new tab)

  2. Design strategies for residential ventilation systems

    In the literature on ventilation, residential ventilation systems have traditionally received less attention due to their relatively low capacity and complexity. Nevertheless, the large energy saving potential of the residential building sector has made it one of the key targets of climate change …

    ghent Repository record for Design strategies for residential ventilation systems (opens in a new tab)

  3. Model Study of Swine Manure Pit Ventilation Systems

    … to both the animal and laborer is a pit ventilation system. A pit ventilation system should exhaust noxious gasses and odors that evolve in the pits before natural or forced convection currents transfer the gasses and odors into the livestock environment. This is especially important when …

    sdstate Repository record for Model Study of Swine Manure Pit Ventilation Systems (opens in a new tab)

  4. Fuzzy logic control of residential mechanical ventilation systems

    Includes bibliographical references (pages 130-134).

    colo-mines Repository record for Fuzzy logic control of residential mechanical ventilation systems (opens in a new tab)

  5. A Novel Heat Recovery Device for Passive Ventilation Systems

    … recovery device for integration with a passive ventilation system. Current heat recovery devices are not suitable for integration with passive ventilation systems due to the high pressure drop experienced by airstreams across the devices. This would result in low ventilation supply rates …

    whiterose Repository record for A Novel Heat Recovery Device for Passive Ventilation Systems (opens in a new tab)

  6. Operating characteristics and stability of multiple-fan ventilation systems.

    … related to a subsystem of a multiple-fan ventilation system are established. It has been found that an augmented system has a unique solution curve and all the possible system solution points are located on the curve at the points where the augmented parameter has a zero value. The …

    wvu Repository record for Operating characteristics and stability of multiple-fan ventilation systems. (opens in a new tab)

  7. Pit Ventilation Systems Performance in a Model Swine Building

    The evaluation of pit ventilation systems performance by comparing air flow velocities, air currents, and evacuation times is needed to develop the information needed for proper engineering design. Therefore, a research project employing scale models of five pit ventilation systems and employing …

    sdstate Repository record for Pit Ventilation Systems Performance in a Model Swine Building (opens in a new tab)

  8. Improving air distribution in deep-level mine ventilation systems

    … underground mine conditions results in fewer ventilation-related fatalities and increases productivity. The objective of a subsurface ventilation system is to ensure sufficient quantity and quality of airflow in the working areas of a mine. Deep-level mines are typically overventilated with …

    nwu-za Repository record for Improving air distribution in deep-level mine ventilation systems (opens in a new tab)

  9. Critical Analysis of Longwall Ventilation Systems and Removal of Methane

    Bleeder systems are an important component for ventilation and the control of methane. The bleeder system of a coal mine contains a mixing zone for methane-laden air from the mined-out portions of the seam to mix with fresh air and the methane concentrations in the bleeders can often be elevated. …

    wvu Repository record for Critical Analysis of Longwall Ventilation Systems and Removal of Methane (opens in a new tab)

  10. Effectiveness of the "common" method in balancing exhaust ventilation systems

    … to adjust the distribution of airflows in duct systems. The "common"(i.e., most commonly used) method is to adjust each damper in turn so that the airflow through its branch equals the desired level. Typically, the airflow through each branch duct is estimated from the centerline velocity …

    wvu Repository record for Effectiveness of the "common" method in balancing exhaust ventilation systems (opens in a new tab)

  11. Optimize Ventilation Systems in Confined Workplaces Using Computational Fluid Dynamics

    … this goal is now more critical than ever. The ventilation system is the most common engineering method to control the airborne toxic and explosive material in confined workplaces. The purpose of ventilation is to dilute or remove the toxic and explosive vapors with air to prevent potential …

    tamu Repository record for Optimize Ventilation Systems in Confined Workplaces Using Computational Fluid Dynamics (opens in a new tab)

  12. Improving the operational efficiency of deep-level mine ventilation systems

    … sources, confined spaces and high temperatures. Ventilation of working areas is a challenge due to the intricacy of underground networks after years of mining and development. As a result, ventilation systems are outdated and lack optimised control. Literature shows numerous studies about the aid …

    nwu-za Repository record for Improving the operational efficiency of deep-level mine ventilation systems (opens in a new tab)

  13. A comparison of conventional and CO₂ demand-controlled ventilation systems

    concordia

  14. Digital twinning and transient analysis for fault diagnosis in ventilation systems

    … system, which is a fan motor system used for ventilation in industrial settings. By analyzing the motor current, we identify system faults, without any additional sensors. We study the common system defects. The study is based on transient signal analysis. We developed two approaches to detect …

    star-france Repository record for Digital twinning and transient analysis for fault diagnosis in ventilation systems (opens in a new tab)

  15. Optimization of control device locations and sizes in mine ventilation systems

    … methodology for solving the semi-controlled ventilation network problem. After analysis and consideration of the objective and legal, technical and operation convenience factors, the semi-controlled network problem is formulated through a nonlinear nonconvex programming model. Using the …

    vt Repository record for Optimization of control device locations and sizes in mine ventilation systems (opens in a new tab)

  16. Zeolite Membrane Water Vapor Separation for Building Air-Conditioning and Ventilation Systems

    … study for dehumidification in building ventilation and air-conditioning systems. The dependence of membrane water and air permeance from inlet airflow parameters (flow rate, humidity, temperature), and permeate total pressure was experimentally studied. Based on the obtained results, the …

    tamu Repository record for Zeolite Membrane Water Vapor Separation for Building Air-Conditioning and Ventilation Systems (opens in a new tab)

  17. DEVELOPMENT OF INDUSTRY ORIENTED CFD CODE FOR ANALYSIS / DESIGN OF FACE VENTILATION SYSTEMS

    … in the last three decades concerning the face ventilation for deep cut mining showed very complicated airflow behavior. The specifics of flow patterns developed by the face ventilation systems presents significant challenge for analytical description even for equipment-free entry. Fortunately, …

    uky-thes Repository record for DEVELOPMENT OF INDUSTRY ORIENTED CFD CODE FOR ANALYSIS / DESIGN OF FACE VENTILATION SYSTEMS (opens in a new tab)

Page 1 of 14