Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Vibrating wire strain"”.

  1. A study of the stud-welded vibrating wire strain gage

    … which affect the stability of a stud-welded vibrating wire strain gage. The lack of previously published information and the nature of the instrument required an origonal design. When undesirable conditions were noted, an attempt has been made to eliminate such conditions through a change in …

    rice Repository record for A study of the stud-welded vibrating wire strain gage (opens in a new tab)

  2. Calcium Sulfoaluminate Cement Concrete for Prestressed Bridge Girders: Prestressing Losses, Bond, and Strength Behavior

    … Prestress losses were monitored long-term using vibrating wire strain gages cast into the concrete at the level of the prestressing strands and the data was compared to the American Association of State Highway and Transportation Officials Load and Resistance Factor Design (AASHTO LRFD) …

    utahstate Repository record for Calcium Sulfoaluminate Cement Concrete for Prestressed Bridge Girders: Prestressing Losses, Bond, and Strength Behavior (opens in a new tab)

  3. Prestress Losses and Temperature Effects on a Deck Bulb Tee Girder Bridge

    … in prestress were measured with a total of 16 vibrating wire strain gauges located at four cross-sections. Temperature gradients were measured with a total of 50 thermocouples located at five cross-section locations, four of which were shared locations with the vibrating wire strain gauges. …

    utahstate Repository record for Prestress Losses and Temperature Effects on a Deck Bulb Tee Girder Bridge (opens in a new tab)

  4. Prop loads in two large braced excavations

    … As well as prop loads, which were measured using vibrating wire strain gauges, prop temperatures were monitored in order to assess their influence on the prop loads. The research has shown that</p><p>(i) Vibrating wire strain gauges can accurately and reliably monitor the loads developed in …

    soton Download PDF for Prop loads in two large braced excavations (opens in a new tab)

  5. Controlling Expansion Behavior Through Curing and Mix Design for An Expansive, Rapid-Setting BCSA Cement

    … could be caused by the concrete’s expansion. Vibrating wire strain gauges (VWSG) inside restrained and unrestrained cylinder specimens were used to collect strain data from the concrete. It was found that the expansive BCSA cement can achieve a maximum expansion of 75 με in 28 days. It can …

    arkansas Repository record for Controlling Expansion Behavior Through Curing and Mix Design for An Expansive, Rapid-Setting BCSA Cement (opens in a new tab)

  6. Dowel-concrete contact characteristics

    … were measured using a novel laboratory setup of vibrating wire strain gauges embedded in both the dowel and concrete. The gages are set to measure the shrinkage strain induced in the concrete that surrounds the dowel as it cures causing the solidified concrete to clamp on the steel dowel. The …

    wvu Repository record for Dowel-concrete contact characteristics (opens in a new tab)

  7. Prestress Losses in Lightweight Self-Consolidating Concrete

    … clay, expanded shale, and limestone aggregates. Strains in the beams were measured with vibrating-wire strain gages, and the measured prestress losses were compared with current AASHTO methods for calculating prestress losses. The AASHTO approximate method better predicted actual losses than did …

    arkansas Repository record for Prestress Losses in Lightweight Self-Consolidating Concrete (opens in a new tab)

  8. Monitoring and Fatigue Analysis of Suspension Bridge Rocker Arms

    … of a monitoring system consisting of 32 vibrating wire strain gauges. This thesis describes the collection and processing of the monitoring data. The data was used to develop a fatigue damage assessment for the rocker arms. Baseline data for fatigue damage was provided by an assessment of …

    queens Repository record for Monitoring and Fatigue Analysis of Suspension Bridge Rocker Arms (opens in a new tab)

  9. Evaluation of high strength lightweight concrete precast, prestressed bridge girders

    … All 5 girders of span 2 were instrumented with vibrating wire strain gages at midspan, as well as with DEMEC inserts for transfer length measurements and with a deflection measurement system. Transfer length measurements found the transfer length of the girders to be 23% less than the values …

    gatech Repository record for Evaluation of high strength lightweight concrete precast, prestressed bridge girders (opens in a new tab)

  10. Development of Self-Stressing Ultra High-Performance Concrete using Expansive Chemical Admixtures

    … cement. Various mix designs were tested using vibrating wire strain gauges on concrete cylinders during the curing phase. These tests confirmed the hypothesis that increasing the amount of chemical admixture increases the amount of measured strain developed as the concrete hardened. To test the …

    arkansas Repository record for Development of Self-Stressing Ultra High-Performance Concrete using Expansive Chemical Admixtures (opens in a new tab)

  11. Mitigating Shrinkage Cracking of Concrete in Bridge Decks Through Internal Curing

    … both plastic and elastic states using embedded vibrating wire strain gages (VWSG) cast in concrete prisms. The expanded clay LWA mixtures, with the 300 lb. replacement rate yielding the best results, were most effective in reducing shrinkage. Compressive strength decreased as the amount of LWA …

    arkansas Repository record for Mitigating Shrinkage Cracking of Concrete in Bridge Decks Through Internal Curing (opens in a new tab)

  12. Study of Internal Strains Developed in Concrete Decks at Early Ages in Steel Continuous Bridges

    … testing. A bridge deck was instrumented with 32 vibrating wire strain gauges prior to concrete placement to investigate strain and temperature changes in the first 14 days. Eurocode and ACI approximations for concrete mechanical properties were compared to field measured data for improving the …

    arkansas Repository record for Study of Internal Strains Developed in Concrete Decks at Early Ages in Steel Continuous Bridges (opens in a new tab)

  13. Behavior during construction of ramp B over I-40 in Nashville, TN

    … behavior during construction was monitored using vibrating wire strain gages, clinometers, and a robotic total station. Through these technologies it was possible to monitor changes in strain/stress, angle of rotation, and deflections throughout the girder erection, installation of concrete …

    gatech Repository record for Behavior during construction of ramp B over I-40 in Nashville, TN (opens in a new tab)

  14. Automated manufacturing of smart tunnel segments

    … practices, identifying structural strains as the most monitored parameters. Vibrating Wire Strain Gauges (VWSGs) were identified as the most suitable sensors for this application due to their compatibility with a modular system and superior long-term properties, especially when …

    strathclyde Repository record for Automated manufacturing of smart tunnel segments (opens in a new tab)

  15. Field Test of a Bridge Deck with Glass Fiber Reinforced Polymer Bars as the Top Mat of Reinforcement

    … in the field under service conditions. The strains and deflections in the span reinforced with GFRP in the top mat were recorded under a series of truck crossings, and these were compared to the span reinforced with all steel bars under identical loading conditions, as well as design values …

    vt Repository record for Field Test of a Bridge Deck with Glass Fiber Reinforced Polymer Bars as the Top Mat of Reinforcement (opens in a new tab)

  16. The Short and Long-Term Effects of Temperature and Strain on a Concrete Bulb-Tree Girder Bridge

    … contained a total of 50 thermocouples and 16 vibrating wire strain gauges. These instruments were placed at the mid-span and end of an exterior girder and the mid-span, quarter-span, and end of a center girder in order to effectively monitor the bridge response in one quarter of the bridge …

    utahstate Repository record for The Short and Long-Term Effects of Temperature and Strain on a Concrete Bulb-Tree Girder Bridge (opens in a new tab)

  17. Structural and geotechnical interpretation of strain gauge data from laterally loaded reinforced concrete piles

    … geotechnical behaviour of the stabilised slopes. Vibrating wire strain gauges are used for the calculation of the bending moment applied to the piles, while inclinometers are used to measure the displacements. A review of the instrumentation has been carried out and a methodology for processin and …

    soton Download PDF for Structural and geotechnical interpretation of strain gauge data from laterally loaded reinforced concrete piles (opens in a new tab)

  18. Using non-linear vibration techniques to detect damage in concrete bridges

    … various damage levels. They involved the use of vibrating wire strain gauges to investigate the moment-rotation behaviour over the cracked region. Several possible non-linear crack mechanisms are discussed and two of them are assessed using the vibration and the static load tests. Future …

    oxford Repository record for Using non-linear vibration techniques to detect damage in concrete bridges (opens in a new tab)

  19. Characterization of "t-z" model design parameters for augered cast-in-place piles using field load test data

    … gauge readings from the pile heads as well as vibrating wire strain gauge data from multiple locations throughout several of the test piles. The “t-zâ€� method has been used extensively as a soil-structure interaction model to evaluate the settlement of deep foundations. The soil-structure …

    umkc Repository record for Characterization of "t-z" model design parameters for augered cast-in-place piles using field load test data (opens in a new tab)

  20. Field Instrumentation and Testing to Study Set-up Phenomenon of Driven Piles and Its Implementation in LRFD Design Methodology

    … goal, all the test piles were instrumented with vibrating wire strain gages. Vibrating wire piezometers and pressure cells were also installed in the pile face in order to calculate the dissipation of excess pore water pressure, together with the corresponding increase in effective stress, …

    lsu-thes Repository record for Field Instrumentation and Testing to Study Set-up Phenomenon of Driven Piles and Its Implementation in LRFD Design Methodology (opens in a new tab) Restricted access

Page 1 of 2