Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"Vibration Serviceability"”.

  1. Vibration Serviceability of Cold-Formed Steel Floor Systems

    Excessive vibration in response to human activities has been a significant problem associated with lightweight steel floor systems, especially cold-formed steel (CFS) floors. Methods for accurately predicting these vibrations and evaluating floor systems are not readily available to the design …

    waterloo Repository record for Vibration Serviceability of Cold-Formed Steel Floor Systems (opens in a new tab)

  2. Some aspects of vibration serviceability in wood floor systems

    … predict acceptability of wood floor systems to vibrations resulting from human footfall impacts. Included in the database are floors tested previously unoccupied which were tested again with occupancy loading. Additional occupied and unoccupied wood floor systems not included in the original …

    vt Repository record for Some aspects of vibration serviceability in wood floor systems (opens in a new tab)

  3. Vibration Serviceability Assessment of a Steel Modular Floor System

    … and erection but also on satisfying floor vibrations, as it was determined to be the governing limit state of the plate thickness, section sizes, and beam spacing due to the presence of an unstiffened bare plate acting as a slab. Observations were performed regarding fabrication sequence …

    vt Repository record for Vibration Serviceability Assessment of a Steel Modular Floor System (opens in a new tab)

  4. Evaluation and Calibration of Pedestrian Bridge Standards for Vibration Serviceability

    … bridges. A prominent example for this is the serviceability failure of the London Millenium Bridge in 2001, where excessive vibrations from inauguration crowds resulted in shutting down the structure. While the bridge was subsequently retrofitted with damping devices, this incident brought …

    waterloo Repository record for Evaluation and Calibration of Pedestrian Bridge Standards for Vibration Serviceability (opens in a new tab)

  5. Vibration serviceability of long-span cast in-situ concrete floors.

    This thesis describes an investigation into the vibration serviceability of long-span and slender in-situ concrete floors, which are typically post-tensioned. The motivation for the research is the present trend towards increased slenderness of post-tensioned floors supporting open-plan high- …

    whiterose Download PDF for Vibration serviceability of long-span cast in-situ concrete floors. (opens in a new tab)

  6. Vibration Serviceability and Dynamic Modeling of Cold-Formed Steel Floor Systems

    … cold-formed steel floor systems can result in vibration serviceability issues if proper design considerations are not made. Providing sufficient damping within the structure is the most effective way to ensure that occupants are comfortable under typical residential and office service loads. …

    waterloo Repository record for Vibration Serviceability and Dynamic Modeling of Cold-Formed Steel Floor Systems (opens in a new tab)

  7. VIBRATION SERVICEABILITY ASSESSMENT OF A LIGHTWEIGHT COLD-FORMED STEEL FLOOR SYSTEM

    The following research examines the serviceability of a proposed lightweight cold-formed steel floor system. Finite element and experimental methods are used to evaluate said system against serviceability criteria and further develop FE modeling methods for predicting the response of floor …

    ku Repository record for VIBRATION SERVICEABILITY ASSESSMENT OF A LIGHTWEIGHT COLD-FORMED STEEL FLOOR SYSTEM (opens in a new tab)

  8. Dynamic Testing of In-Situ Composite Floors and Evaluation of Vibration Serviceability Using the Finite Element Method

    … composite floors for the purpose of evaluating vibration serviceability. The measurement, analysis, and computation of a floor's accelerance frequency response function (FRF) is the core premise linking all areas of the presented research. The burst chirp signal using an electrodynamic shaker is …

    vt Repository record for Dynamic Testing of In-Situ Composite Floors and Evaluation of Vibration Serviceability Using the Finite Element Method (opens in a new tab)

  9. Vibration serviceability of special footbridges in South Africa: an investigation of the crowd capacity of the Boomslang canopy walkway

    The vibration serviceability of footbridges subjected to pedestrian loading has been an academic pursuit since the year 1850 (Fujino & Siringoringo, 2015). Initially, research was focussed on understanding the influence of pedestrian vertical loading on the dynamic behaviour of a footbridge. …

    cape-town Repository record for Vibration serviceability of special footbridges in South Africa: an investigation of the crowd capacity of the Boomslang canopy walkway (opens in a new tab)

  10. Vibrations of precast and partially prestressed floor systems under moving loads: development of a dynamic fork-lift truck model for vibration serviceability analysis and its application

    … Currently, there are concerns whether the vibrations caused by fork-lift trucks might exceed acceptable limits due to an ongoing trend towards structures of higher slenderness. This study investigates the mechanical background of the excitation and the current design of the floor system. …

    oxford Restricted access

  11. Probability-based estimation of vibration for pedestrian structures due to walking.

    … increasingly slender and therefore more prone to vibrations generated by people. As a consequence, the vibration serviceability of these structures is becoming their governing design criterion. Currently, the design procedures for the vibration serviceability check used in practice are mainly of a …

    whiterose Download PDF for Probability-based estimation of vibration for pedestrian structures due to walking. (opens in a new tab)

  12. The effects of raised access flooring on the vibrational performance of long-span concrete floors.

    … resulting in more frequent problems with their vibration serviceability. Predictive methods for vibration serviceability must consider not only the structures themselves, but also the non-structural elements which are attached to them, as these may have a significant effect on the dynamic …

    whiterose Download PDF for The effects of raised access flooring on the vibrational performance of long-span concrete floors. (opens in a new tab)

  13. Investigation of Human-Structure Interaction Through Experimental and Analytical Studies

    Vibration serviceability is a widely recognized design criterion for assembly-type structures, such as stadiums, that are likely subjected to rhythmic human-induced excitation. Human-induced excitation of a structure occurs from the movement of the occupants such as walking, running, jumping, or …

    bucknell Repository record for Investigation of Human-Structure Interaction Through Experimental and Analytical Studies (opens in a new tab)

  14. Vibration Behaviour of Glulam Beam-and-Deck Floors

    Low-amplitude floor vibrations have become a governing serviceability performance design consideration for floors constructed with low mass-to-stiffness ratio materials such as wood. Studies reported here were conducted at the University of Ottawa to assess vibration serviceability performance of …

    ottawa-retro Repository record for Vibration Behaviour of Glulam Beam-and-Deck Floors (opens in a new tab)

  15. HYBRID CONTROL OF HUMAN-INDUCED VIBRATION

    … excite the structure in resonance resulting in vibration serviceability issues. One of the available techniques to reduce excessive responses is to use passive vibration control techniques such as Tuned Mass Dampers (TMD). However, the off-tuning problem is a potential drawback of this …

    whiterose Download PDF for HYBRID CONTROL OF HUMAN-INDUCED VIBRATION (opens in a new tab)

  16. Effects of Heavy Topping on Vibrational Performance of Cross-Laminated Timber Floor Systems

    … by a lack of research in various areas, such as vibration serviceability. This has resulted in vague design guidelines, leading to either overly conservative designs, hurting profit margins, or leading to overly lenient designs, resulting in occupancy discomfort. Eliminating these design …

    clemson Repository record for Effects of Heavy Topping on Vibrational Performance of Cross-Laminated Timber Floor Systems (opens in a new tab)

  17. Vibration performance of modular prefabricated cross-laminated timber–steel composite floors

    … composites are not as explored. Studies on the vibration serviceability of mass timber-based floor systems have also received little attention, despite being a crucial governing design consideration. Against this backdrop, this research investigated the vibration characteristics and …

    ubc Repository record for Vibration performance of modular prefabricated cross-laminated timber–steel composite floors (opens in a new tab) Download PDF for Vibration performance of modular prefabricated cross-laminated timber–steel composite floors (opens in a new tab)

  18. Dynamic Interaction of Walking Humans with Pedestrian Structures in Vertical Direction Experimentally Based Probabilistic Modelling

    … is assumed as the mass of the SDOF system. A new vibration serviceability assessment method was proposed that takes into account not only the variability of the human body MSD parameters and the forcing function but also their interaction with the structure. Application of this novel method on two …

    whiterose Download PDF for Dynamic Interaction of Walking Humans with Pedestrian Structures in Vertical Direction Experimentally Based Probabilistic Modelling (opens in a new tab)

  19. VIBRATION OF STEEL-FRAMED FLOORS SUPPORTING SENSITIVE EQUIPMENT IN HOSPITALS, RESEARCH FACILITIES, AND MANUFACTURING FACILITIES

    … been designed only for strength and deflection serviceability. As technological advances have been made in medical, scientific and micro-electronics manufacturing, many types of equipment have become sensitive to vibration of the supporting floor. Thus, vibration serviceability has become a …

    uky-thes Repository record for VIBRATION OF STEEL-FRAMED FLOORS SUPPORTING SENSITIVE EQUIPMENT IN HOSPITALS, RESEARCH FACILITIES, AND MANUFACTURING FACILITIES (opens in a new tab)

Page 1 of 2