Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Vickers hardness test"”.

  1. Fracture Toughness of Dental Amalgams

    This work shows that there is a requirement for a test, in addition to those specified in BS 2938:1985, for predicting the performance of dental amalgams. The SEN type of test to find the fracture toughness (K<sub>IC</sub>) is capable of distinguishing between amalgams that are reputed to have …

    the-open-u Download PDF for Fracture Toughness of Dental Amalgams (opens in a new tab)

  2. Processing and characterization of multi-walled carbon nanotube reinforced aluminium metal matrix composite

    … composites were subjected to standard Vickers hardness test and MPIF standard tensile test to investigate the mechanical properties of the composite.

    birmingham Download PDF for Processing and characterization of multi-walled carbon nanotube reinforced aluminium metal matrix composite (opens in a new tab)

  3. As-deposited microstructure and tensile behavior of solid-state additive manufactured Ti–6Al–4V

    … and Energy Dispersive Spectroscopy (EDS). A Vickers hardness test measured the hardness of the AFS-D Ti64 deposition cross section. Quasi-static tensile experiments performed on as-built AFS-D Ti64 samples quantified the strength and ductility, and the results were compared to the data …

    alabama Repository record for As-deposited microstructure and tensile behavior of solid-state additive manufactured Ti–6Al–4V (opens in a new tab)

  4. Influência do clareamento dentário de consultório na dureza superficial de resinas compostas: um estudo in vitro

    The study aimed to evaluate the surface hardness of three composite resins (Filtek Z350 - 3M ESPE, Zirconfil - TECHNEW, Vitra - FGM), after an in-office tooth whitening process using 40% hydrogen peroxide. Sixty specimens were made, with thicknesses of 6.0 x 2.0 mm, with 20 specimens of each …

    brazil-ufrn Repository record for Influência do clareamento dentário de consultório na dureza superficial de resinas compostas: um estudo in vitro (opens in a new tab)

  5. Estudo da sinterização do compósito WC-316L

    … characterized by X-RD diffraction, particle size testing and scanning electron microscopy (SEM). The composite sintered WC- 316L was characterized by SEM and micro vickers hardness test. The samples processed at temperatures of 1200oC and 1300oC showed high porosity heterogeneity microstructural, …

    brazil-ufrn Repository record for Estudo da sinterização do compósito WC-316L (opens in a new tab)

  6. Development and Characterization of Nano-calcium Sulfate/Tri-Calcium Silicate Composite Material for Bone Regeneration Application

    … physical properties, such as setting time, hardness, and degradation rate of nano-calcium sulfate in comparison to a composite of nano-calcium sulfate + 10% tri-calcium silicate cement, as well as to assess possible cytotoxicity effects of the materials in-vitro. Methods: Nano-calcium …

    buffalo Repository record for Development and Characterization of Nano-calcium Sulfate/Tri-Calcium Silicate Composite Material for Bone Regeneration Application (opens in a new tab)

  7. Analyzing the Mechanical Behavior of Additive Manufactured Ti-6Al-4V Using Digital Image Correlation

    … with SLM were heat treated. Samples were tested under quasi-static tensile loading in combination with Digital Image Correlation (DIC) to determine the localized strains. From each tensile test, Young’s modulus, yield strength (Rp0.2), ultimate tensile strength (UTS) and elongation at …

    chalmers Repository record for Analyzing the Mechanical Behavior of Additive Manufactured Ti-6Al-4V Using Digital Image Correlation (opens in a new tab)

  8. Effects of heat treatment on microstructure and mechanical properties of a cobalt based implant material

    … Their mechanical properties were examined by Vickers hardness test, tensile test and Charpy impact toughness test. It was found that the samples consist of a Co-rich matrix with large (10-100μm) carbides spread out in the interdendritic areas. The carbides in the as cast samples have a …

    chalmers Repository record for Effects of heat treatment on microstructure and mechanical properties of a cobalt based implant material (opens in a new tab)

  9. Effect of ceramic density and curing pressure on properties of a resin infused alumina

    … strength, surface roughness, Young’s modulus, hardness and fracture toughness of resin infused alumina. MATERIALS: Alumina infused polymer and Vita In-ceram alumina. METHODS: Alumina powders were dry-pressed in a stainless steel mold to produce cylindrical alumina blocks. Blocks were divided …

    bu Repository record for Effect of ceramic density and curing pressure on properties of a resin infused alumina (opens in a new tab)

  10. TRIBOLOGICAL AND CORROSION PROPERTIES OF FE-BASED BULK METALLIC GLASS COATED ZE41A-T5 MAGNESIUM ALLOY

    As the lightest structural materials, magnesium (Mg) alloys have continued to attract interest because of their enormous potential in engineering applications such as in aerospace, automotive, and electronic industries. However, their inferior wear and corrosion characteristics have significantly …

    sask Repository record for TRIBOLOGICAL AND CORROSION PROPERTIES OF FE-BASED BULK METALLIC GLASS COATED ZE41A-T5 MAGNESIUM ALLOY (opens in a new tab)

  11. Effectiveness of iontophoresis in enhancing remineralisation of carious lesions

    … with iontophoresis technology, using microhardness measurement (Vickers hardness test), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The research presents the outcomes of a variety of different remineralisation regimes to scrutinise the relationship …

    edinburgh Repository record for Effectiveness of iontophoresis in enhancing remineralisation of carious lesions (opens in a new tab)

  12. Microwave Plasma CVD Sythesis of Superhard CNOB Materials

    … properties and practical applications. When the hardness value of the material exceeds 40 GPa by the Vickers hardness test, the material is called superhard. Diamond is the hardest known material with a hardness value of 70-100 GPa. Although diamond is electrically insulating and thermally …

    uab Repository record for Microwave Plasma CVD Sythesis of Superhard CNOB Materials (opens in a new tab)

  13. Analysis of accuracy and mechanical properties of 3D-printed polymeric dental materials

    … flexural strength (N=10) using a threepoint bend test, fracture toughness (N=10), creep (N=5), Vickers hardness test (N=15), surface roughness (N=15), while Shore A hardness (N=15) and tensile strength (N=10) were performed for Keysplint Soft Clear. Data were analyzed using one-way and …

    bu Repository record for Analysis of accuracy and mechanical properties of 3D-printed polymeric dental materials (opens in a new tab)

  14. Rozměrová, tvarová a materiálová analýza bimetalových dílců s definovaným poloměrem ohybu

    Cílem této práce je zhodnocení dosažených výsledků z analýzy trubkových oblouků 180° pro kritický ohyb 1D a superkritický ohyb 0,7D. Teoretická část je zaměřena na charakteristiku materiálu bimetalové trubky a následně jsou popsány metody využité u analýz. Součástí práce je kapitola, která definuje …

    brno-tech Repository record for Rozměrová, tvarová a materiálová analýza bimetalových dílců s definovaným poloměrem ohybu (opens in a new tab)

  15. Analýza mechanických vlastností bimetalových materiálů s cladovanou vrstvou Inconelu

    Tato diplomová práce se zabývá analýzou mechanických vlastností bimetalového materiálu s cladovanou vrstvou Inconelu. V teoretické části práce se nachází rozbor zkoumaného bimetalového materiálu, popis mechanických zkoušek a metod hodnocení integrity povrchu, pomocí kterých docházelo ke zjišťování …

    brno-tech Repository record for Analýza mechanických vlastností bimetalových materiálů s cladovanou vrstvou Inconelu (opens in a new tab)

  16. Electrical discharge machining of non-conductive advanced ceramics

    … have been investigated by EDX analysis, Vickers hardness test, surface roughness analysis and flexural test of ceramics samples at three different process stages. These were 1) samples as obtained from the manufacturer with polished surface, 2) samples immediately after the µ-EDM process …

    freiburg-diss Repository record for Electrical discharge machining of non-conductive advanced ceramics (opens in a new tab)