Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 27 for “"Vicon Nexus"”
-
Reliability and validity of the Polhemus Liberty system for upper body segment and joint angular kinematics of elite golfers
… between data obtained by Polhemus Liberty and VICON Nexus motion capture systems demonstrated small to moderate differences between the golf swing upper body segment and joint angular kinematics. Whilst validity of Polhemus Liberty compared to VICON Nexus could not be confirmed, Polhemus …
-
Contribution à la conception d'un système robotisé pour la télé-échographie
… àl’aide du système de capture de mouvement Vicon Nexus, cette analyse a contribué à l’établissementdes spécifications du futur robot. Sa structure mécanique a fait l’objet d’une attention particulière. Unearchitecture parallèle sphérique a été sélectionnée, étudiée puis optimisée via un …
-
Differences in Loading Rate in Shod and Unshod Treadmill Walking
… a rest period between. Data were analyzed using Vicon Nexus and MatLab and loading rates were extracted for more than 50 strides for each trial. Wearing shoes yielded 33% lower loading rate than walking barefoot. Walking barefoot displayed significantly more variance between strides than walking …
-
Computational Modeling of the Helical Axis in the Human Knee--Detecting Changes in the Transverse Plane
… Innovative Sports Training, Chicago, IL) and Vicon Nexus 1.3 software system (Oxford Metrics Group, Oxford, UK). To test the algorithm under more controlled conditions and eliminate kinematic collection errors, a mathematical model was used. The cylinder model was used to obtain constrained …
-
Creating a real-time movement sonification system for hemiparetic upper limb rehabilitation for survivors of stroke
… subsequently used in a comparison study with a Vicon Nexus system to establish similarity of positional shape, and therefore establish audio output similarity. The results indicate that the Soniccup produced positional shape representative of the movement performed, for movements of duration …
-
Kniestabilität, Kniekinematik und -kinetik nach erfolgreicher Rekonstruktion des hinteren Kreuzbandes im Langzeitverlauf
… (Telos), eine 3-D instrumentierte Ganganalyse (Vicon Nexus) sowie Fragebögen (IKDC, Lysholm, KOOS). Für die Ganganalyse wurden 10 Infrarotkameras zur Bewegungsanalyse während der Durchführung von Alltagsaktivitäten (Gehen, Treppensteigen, -absteigen) verwendet. Als Vergleichsparameter für die …
-
Effect of seat orientation on ingress/egress joint kinematics and reach envelope
… (MX-13 series) optical motion analysis system (Vicon, Nexus, UK) was used to record the 3D kinematic data. Ten healthy male participants performed ingress and egress motions using the following three seat orientations, while reach tasks were only performed in the first two: (1) vertically …
-
The Influence of Strength in Load-Velocity Relationships in the Back Squat
… squat 3D motion analysis was captured using four Vicon T010 cameras (Vicon Motion Systems Ltd.; Oxford, UK) and Vicon Nexus 1.8.5 software. Data were transported into R custom coding statistical analysis software (version 3.5.2; The R Foundation) to calculate velocity analyses which determined …
-
Anatomical and Biomechanical Factors Related to Running Economy in Uphill and Downhill Running
… Various running mechanics were measured using Vicon Nexus and a Bertec treadmill. A linear regression determined any correlations between peak vertical force, stride rate, plantar velocity, and ground time against uphill/downhill running ability. RESULTS: Peak vertical force was the only factor …
-
Investigating Feasibility of Repetitive Transcranial Magnetic Stimulation Targeting Upper Limb Spasticity: A Case Study
… limb spasticity in the future. This study used VICON-Nexus motion capture systems, Electromyography and Inertial Measurement Unit for the lower limb to quantify the changes in the gait pattern and gait phases. This gait study protocol can also be used in the future to analyze freezing of gait in …
-
The Biomechanics of the Tendu in Closing to the Traditional Position, Pli#233; and Relev#233;
… The dancers' movements were tracked using the VICON Nexus motion analysis system and 27 passive reflective markers placed on bony landmarks. Visual 3D software was used to calculate the knee angles. There were statistically significant the differences between knee angles during the traditional …
-
Lower Body Kinetics During the Delivery Phase of the Rotational Shot Put Technique
… throwers trained in the rotational technique. Vicon Nexus System (Denver, CO, USA) used six MX13+, two F20, two T20 cameras recorded at 240 Hz, and the body Plug-in Gait model to track the body position during each trial. Two AMTI force plates (OR-6, Watertown, MA, USA) were used for collecting …
-
Comparison of the Statically Equivalent Serial Chain Center of Mass Estimation Method to OpenSim's Residual Reduction Algorithm
… processed through the motion capture software, Vicon Nexus, and then inverse kinematics, dynamics, and RRA in OpenSim. Finally, the SESC COM estimation was determined using this processed data through a custom MATLAB script, and the magnitude of the error in the horizontal plane of all subjects’ …
-
A comparative evaluation of the effects of incline on kinematics and muscle function during backward walking
… Next, 35 reflective markers were attached (Vicon Fullbody PlugInGait model) for motion capture (200 hz) with a 12 camera Vicon nexus 3D motion capture system (Vicon Motion Systems Ltd, Oxford, UK). Participants next walked for five minutes at each incline (0%, 6%, 8%, 10%, 12%), presented in …
-
Kinetic and Kinematic Properties of D-I Male Sprinters
… were attached on the body landmarks based on Vicon Nexus full body plugin model. The strength assessments were performed in a customized power rack, and kinetic values were collected via a dual force plate setup (2 separate 91 cm x 45.5 cm force plates, Roughdeck HP, Rice Lake, WI). The …
-
The Effect of Two Different Ankle Foot Orthoses on Reactive Stepping in Young, Healthy Adults
… shanks and feet. The trials were recorded with VICON Nexus and processed in Visual 3D to extract kinematic and temporal variables. These variables were run through SPSS for one-way ANOVA analysis with Tukey post-hoc in order to determine any differences between the 3 conditions (cAFO, pAFO and …
-
Examining The Relationship Between Hip Strength Measures And Knee Injury Risk Factors During Side-cutting
… A three-dimensional motion capture system (Vicon, Inc., Centennial, Colorado, USA) with 18 cameras and software (Vicon Nexus, Version 2.2.3) was utilized to capture hip and knee biomechanics during the side-cutting task. Data revealed 7/22 (32%) and 8/22 (36%) of side-cutting biomechanical …
-
Fastpitch Softball Biomechanics: Stride Characteristic Alterations when Throwing Movement Pitches
… at 1500 Hz. The motion capture system used was Vicon MX-F40 and the Bertec 4060 force plates used Vicon Nexus software. All analysis was conducted with a model in Visual3D software. A Shapiro-Wilk normality test was conducted on each group to determine data normality at a significance level of …
-
Validierung der Videoanalysesoftware Kinovea® für die kinematische Ganganalyse des Hundes
… wurde eine kinematische 3D- Bewegungsanalyse (VICON-Nexus 2.12.1 ® + Pro Calc 1.6) durchgeführt, während sie auf einem Laufband liefen. Gleichzeitig wurden die Hunde mit drei Smartphones (iPhone SE, Apple Inc, Cupertino, CA, USA) in einer Entfernung von 1,50 m und einem Aufnahmewinkel von 45°, …
-
A Comparison of Biomechanical Variables, Neuromuscular Control and Strength during Controlled and Unexpected Falls on the Outstretched Hands in Young and Older Women
… A three-dimensional motion capture system (VICON Nexus, VICON, Centennial, CO) and force plate apparatus (OR6-7, AMTI, Watertown, MA) was used to determine the biomechanical measures of peak energy absorption, maximum vertical force, maximum elbow angle and maximum elbow joint extensor …
Page 1 of 2