Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"Vicon system"”.

  1. Comparison of a single-camera system with the 3D Vicon system on the upper limb coordination and trunk compensation in stroke survivors

    … is to compare a cheap, portable single- camera system to the 3D Vicon system on the assessment of upper limb motion in stroke patients. Five healthy participant and five stroke patients took part in this study. Participants were asked to perform a reach to grasp movement in a series of five …

    strathclyde Repository record for Comparison of a single-camera system with the 3D Vicon system on the upper limb coordination and trunk compensation in stroke survivors (opens in a new tab)

  2. Feasibility of Wearable Sensors to Determine Gait Parameters

    A wearable system that can be used in different settings to collect gait parameters on subjects with a mild traumatic brain injury (mTBI) would allow clinicians to collect needed data of subjects outside of the laboratory setting. Mild traumatic brain injuries stem from a number of causes such as …

    usf Repository record for Feasibility of Wearable Sensors to Determine Gait Parameters (opens in a new tab)

  3. Development and Validation of a Smart Hallway for Human Stride Analysis Using Marker-Less 3D Depth Sensors

    … programs, and indicating progression of nervous system related disorders. Marker based motion analysis systems are accurate for stride analysis but are not feasible for monitoring larger populations since external markers or sensors must be attached on the body. These external markers or sensors …

    ottawa-retro Repository record for Development and Validation of a Smart Hallway for Human Stride Analysis Using Marker-Less 3D Depth Sensors (opens in a new tab)

  4. Multi-Modal Landmark Detection and Tracking for Odometry Estimation in Degraded Visual Environments

    … approach is compared to ground-truth provided by Vicon system and a state-of-the-art visual-inertial odometry estimation framework. The mapping performance is demonstrated by mapping a large room in dark conditions.

    unr Repository record for Multi-Modal Landmark Detection and Tracking for Odometry Estimation in Degraded Visual Environments (opens in a new tab)

  5. Concurrent Validity Study of 3D Motion Measurement Systems: VICON vs. Xsens

    As the Inertial Measurement System (IMS) being a potential alternative to the Optoelectronic Measurement System (OMS) in terms of capturing comprehensive and objective musculoskeletal data, they need to be verified concurrently with the OMS before we start using the IMS in clinical motion analysis. …

    gvsu Repository record for Concurrent Validity Study of 3D Motion Measurement Systems: VICON vs. Xsens (opens in a new tab)

  6. Impairment in Dynamic Postural Control Following an Acute Lateral Ankle Sprain

    … initiation, which will be assessed using the Vicon system and then compared to matched healthy control values. MANOVA revealed no significant difference in dynamic postural control following a lateral ankle sprain when compared to control group. Significant differences were found in range of …

    gsu Repository record for Impairment in Dynamic Postural Control Following an Acute Lateral Ankle Sprain (opens in a new tab)

  7. Possible applications of markerless pose estimation and GenAI for gait analysis

    … gait analysis compared to existing high accuracy systems such as Vicon. Additionally we explore the possibility of using generative AI models to perform automatic gait analysis using data extracted from these open-source pose estimation models. We evaluate the accuracy of OpenCap compared to the …

    reykjavik Repository record for Possible applications of markerless pose estimation and GenAI for gait analysis (opens in a new tab)

  8. A Computer-Based Instrumentation System for the Dynamic Analysis of Foot and Ankle Motion

    … can support such studies, there are no systems currently available. This study was undertaken in order to develop a 3D motion analysis capable for the study of the foot and ankle structure during adult ambulation. Clinical studies of pediatric gait have been reported by numerous authors …

    marquette Repository record for A Computer-Based Instrumentation System for the Dynamic Analysis of Foot and Ankle Motion (opens in a new tab)

  9. Multi-Camera System for 3D Human Pose Reconstruction

    … model. Usually we can get this information via VICON system. But when we want to collect data from a different room or open-space environment, VICON is not feasible. Although we can use other means like open-pose or deeplabcut to get such kind of information, they are too computationally …

    buffalo Repository record for Multi-Camera System for 3D Human Pose Reconstruction (opens in a new tab)

  10. A Benchmark with Multi-Sensor Fusion for UAV Detection and Distance Estimation

    … are categorized from RGB images, thermal images, VICON data, GPS data, and 2D LiDAR data. All sensors are calibrated and synchronized from frame to frame. The database obtained mimic real scenarios with high quality datasets and potential noises. It is a great resources for some researches …

    buffalo Repository record for A Benchmark with Multi-Sensor Fusion for UAV Detection and Distance Estimation (opens in a new tab)

  11. Visualisation of back movement using the Motek D-flow software and the Vicon motion capture system

    … Netherlands, in conjunction with a 8-camera VICON system, VICON, Oxford, United Kingdom. This was achieved using a series of scripting modules written in Lua to recognise a set of 5 clusters each with 4 markers placed on key anatomical structures on both the spine and legs and then compare …

    strathclyde Repository record for Visualisation of back movement using the Motek D-flow software and the Vicon motion capture system (opens in a new tab)

  12. Visual recognition using hybrid camera

    … all the ground truth automatically labeled by Vicon system. Our people finder can achieve good results on this dataset. Also with the RGB information, we implemented efficient image classification algorithm for people counting in vehicles application. To identify the number of occupants in a …

    missouri Repository record for Visual recognition using hybrid camera (opens in a new tab)

  13. The effect a cosmetic cover has on the swing phase of a transfemoral prosthesis during level walking : a pilot study

    … and new cosmetic cover with stockings. The VICON system was used to motion capture the markers attached to the subject's lower limb on each walk trials of each scenario. The parameters investigated were: knee flexion range, knee angle during one gait cycle, step length, stride length and …

    strathclyde Repository record for The effect a cosmetic cover has on the swing phase of a transfemoral prosthesis during level walking : a pilot study (opens in a new tab)

  14. Validation of Meta Motion IMU Sensors Through Measurement of Knee Angles During Gait

    … for validity against a dynamometer and the Vicon motion capture system. Both systems have proven their measuring accuracies in the biomechanics world and are used as the truth source for this validation study. In the first part of this study, the sensors are assessed for various common …

    odu Repository record for Validation of Meta Motion IMU Sensors Through Measurement of Knee Angles During Gait (opens in a new tab)

  15. Enhancing Human Key Point Identification: A Comparative Study of High-Resolution VICON Dataset and COCO Dataset Using BPNET

    … a high-resolution dataset created using the VICON motion capture system and three differently oriented 2D cameras, that can be used to train different neural networks for estimating the 2D key joint positions of the person from the 2D images or videos. The participants in the study included …

    gvsu Repository record for Enhancing Human Key Point Identification: A Comparative Study of High-Resolution VICON Dataset and COCO Dataset Using BPNET (opens in a new tab)

  16. A biomechanical analysis of stair ascent and descent in older adults

    … older age. Data were collected using an 8 camera VICON system with a custom built staircase enabling forces to be recorded from 2 Kistler force platforms. A full body biomechanical model was developed to comply with the best practice standards using VICON bodybuilder. Temporal data, joint …

    strathclyde Repository record for A biomechanical analysis of stair ascent and descent in older adults (opens in a new tab)

  17. The Acute Effects of Whole-Body Corrective Exercise on Postural Alignment

    … = 25) group. A three-dimensional motion analysis Vicon system was employed to quantify standing postural alignment at the beginning and end of a 6 d study. Postural misalignments were determined in degrees of symmetry (tilt) and rotation using horizontal and vertical virtual plumb lines for the …

    byu Repository record for The Acute Effects of Whole-Body Corrective Exercise on Postural Alignment (opens in a new tab) Download PDF for The Acute Effects of Whole-Body Corrective Exercise on Postural Alignment (opens in a new tab)

  18. Design and Development of a High-Performance Quadrotor Control Architecture Based on Feedback Linearization

    … of a high-performance quadrotor control system for an AscTec Hummingbird quadrotor using direct motor speed control within a Vicon motion capture system environment. A Ground Control Station (GCS) acts as a user interface for selecting flight patterns and displaying sensor values. An …

    unm Repository record for Design and Development of a High-Performance Quadrotor Control Architecture Based on Feedback Linearization (opens in a new tab)

  19. Validation of a navigated hip replacement surgery system

    … (TM) Hip Suite (BBraun Aesculap) is one such system used for hip navigation in orthopedic surgery. However the accuracy of this system remains to be determined independently of the manufacturer. The manufacturer supplies a technical specification for the accuracy of the system (± 2 mm and ± …

    strathclyde Repository record for Validation of a navigated hip replacement surgery system (opens in a new tab)

  20. Impact of Next Generation AM-PET Helmet and Support Structure on Subjects' Neck

    … ring weight of ~3 kilograms. This prototype system was developed by researchers at West Virginia University's Health Science Center (HSC) and has been tested successfully. The next generation helmet, currently being developed, will allow for improved images with additional sensor rings to …

    wvu Repository record for Impact of Next Generation AM-PET Helmet and Support Structure on Subjects' Neck (opens in a new tab)

Page 1 of 2