Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 306 for “"Viscometer"”.
-
Microfluidic Viscometer for Tear Films and Other Biofluids
A microfluidic viscometer platform is developed and validated for measuring microliter-volume liquid samples, such as human tear films. The microfluidic viscometer combines an optically clear acrylic chip with a hydrophobic surface coating together with a syringe pump to control the sample flow …
-
Rheology of non-Newtonian slurries using a Stormer viscometer
Includes bibliographical references.
-
Stress relaxation of glass using a parallel plate viscometer
… shear of Pyrex¨ glass by using a Parallel Plate Viscometer (PPV). The PPV machine was originally created to measure the viscosity of glass solid cylinders by compression. It is used in this study for creep-recovery tests of glass samples. With this study we want to know if we are able to measure …
-
Viscosity Measurements Using a Multiple Frequency Matching Layer Viscometer
… its viscosity. The ultrasonic shear reflection viscometer had to be adapted to measure the viscosity of lubricating oils because the majority of the signal was reflected as the difference in the acoustic impedance of the piezoelectric crystal and oil was too great. This made it impossible to …
-
Evaluation of fluid foods using a helical ribbon viscometer
Thesis (M.S.)--Michigan State University. Department of Food Science and Human Nutrition, 2001
-
Numerical study of particle dynamics in a falling-ball viscometer
The falling-ball viscometer is a device where a spherical particle falls along the axis of a circular cylinder filled with viscous fluid. The various classical results for this device are developed under the assumption that the Reynolds number of the flow is zero, i.e., Stoke's flow. Inertial …
-
The Characterization of Foamed Asphalt Binders Using a Rotational Viscometer
… is through viscosity testing using a rotational viscometer. The standard method of using a viscometer to measure the viscosity of asphalt binder is insufficient when dealing with foamed asphalts, so a new method has been created along with 4 metrics to analyze the data to characterize foamed …
-
Methods to characterize power law fluids using a Brookfield viscometer
Thesis (M.S.)--Michigan State University. Department of Agricultural Engineering, 1995
-
Viscosity Changes of Starches As Studied with the Digestion-Flask Viscometer
… adaptability of the all-glass digestion-flask viscometer. A considerable amount of work had been done on protein material using this instrument, and a few investigations had been carried out on starches with this viscometer. It was Dr. John R. Koch who suggested in a conference that the most …
-
Design criteria for an on-line viscometer for baby food puree
Thesis (M.S.)--Michigan State University. Department of Agricultural Engineering, 1987
-
DETECTION OF PHASE INVERSION IN OIL–WATER MIXTURES USING ONLINE VIBRATIONAL VISCOMETER
… with a square mixing tank, standardizing the viscometer with a well-accepted rheometer, and studying 2 phase properties in a characterized mixing tank designed as per chemical engineering standards. The graphs plotting the phase inversion data were found to follow similar trends as graphs …
-
Shear stress effects on cultured hybridoma cells in a rotational couette viscometer
… damage were investigated in a rotational couette viscometer. The shear sensitivity of the cells was modulated by the age of the culture. For cells that experience a prolonged stationary phase, the cells were quite sensitive to shear for both young and old cultures. If the stationary phase was …
-
The application of a modified MacMichael viscometer in rheologic studies of montmorillonite clays
Available instruments for viscosity and rheologic measurements necessitate disruption of the system under test prior to observations. Generally, the gel structure of a thixotropic clay must be disturbed by shaking, pouring into a container for testing, and again upon insertion into the sample of …
-
Determination of the rheological properties of non-Newtonian fluids with a Hoeppler Rheo-Viscometer
… by performing experiments with a Hoeppler Rheo-Viscometer. The equations are obtained by applying a technique previously used to predict non-Newtonian flow behavior in ducts. The technique is expanded to include the varying cross-section of the slit between the ball and tube.</p>
-
Viscosity measurements at pressures up to 14 000 bar using an automatic falling cylinder viscometer
… principle of a cylindrical sinker falling in a viscometer tube. It departs from earlier systems in that the sinker is retrieved electromagnetically rather than by rotating the whole pressure vessel, and the sinker is held by a semi-permanent magnet before a fall time measurement is made. The …
-
Rheology of hydrate slurries: transferability between a laboratory viscometer and a pilot scale flow loop
Includes bibliographical references (pages 107-110).
-
Red blood cell damage by shearing stress: a study on secondary effects in the concentric cylinder viscometer
… been investigated in the concentric cylinder viscometer. It has been demonstrated that at high shearing rates, such as can occur in an insufficient artificial valve, red cells undergo hemolysis and morphological changes similar to those seen in vivo. There are difficulties involved in the …
Page 1 of 16