Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"Vmin"”
-
A Numerical Analysis Approach For Estimating The Minimum Traveling Wave Speed For An Autocatalytic Reaction
… hand, when DA ≤ DB there exists a minimum speed vmin, such that there is a traveling wave solution if the speed v > vmin. The determination of vmin is very important in determining the dynamics of general solutions. To fill in the gap of the theoretical study, we use numerical methods to …
-
Pessimism of memory built in self test screening with elevated back bias and core voltage
… provides a means of detecting the effects of Vmin drift often associated with burn-in and time dependent wear-out mechanisms. The following thesis explores the application of utilizing VNW biasing and manipulation of Core operating voltage VDD to model and predict parametric Vmin drift in …
-
Micro-Viruses for Fast and Accurate Characterization of Voltage Margins and Variations in Multicore CPUs
… τάσης, με άλλα λόγια την ελάχιστη δυνατή τάση Vmin. Περιγράφουμε την ανάπτυξη των διαγνωστικών μικρό-ιών που στοχεύουν ξεχωριστά τα τρία επίπεδα των κρυφών μνημών και τις βασικές μονάδες επεξεργασίας, την αριθμητική μονάδα ακέραιων αριθμών και την αριθμητική μονάδα αριθμών κινητής υποδιαστολής. …
-
Utilidad de la resonancia magnética en pacientes con fibrilación auricular tributarios de tratamiento con ablación percutánea de las venas pulmonares
… izquierdo (Vmax), el volumen telesistólico (Vmin) así como la fracción de eyección auricular izquierda (FEAI).<br/>La incidencia de estenosis de las VPs se evaluó mediante RM en una serie de 73 pacientes con FA refractaria al tratamiento médico sometidos a APRF de las VPs, bien mediante …
-
Oküler Behçet Hastalığında renkli dupleks sonografi
… daha sonra SRA, NPSA, TPSA, OA'lerine ait Vmax, Vmin, Vort, RI, PI değerleri ile SRV'nin akım hızı incelendi. internal karotis arterin Vmax değerleri göz tutulumu olan Behçet'li gruplarda (hem aktif hem de inaktif üveitli) KG'na göre istatistiksel olarak anlamlı düşük bulundu. Santral retinal …
-
Design techniques for ultra-low voltage sub-threshold circuits and on-chip reliability monitoring.
… fully-automated statistical measurements of SRAM Vmin degradation induced by NBTI. An automated test sequence collects Vmin data for statistical analysis and reduces measurement time. Various test strategies were proposed for Vmin measurements to identify different SRAM fail metrics such as SNM …
-
Algorithms for Simple Stochastic Games
… a subset VMAX and player MIN controls a subset VMIN of vertices. The remaining vertices fall into either VAVE, a subset of vertices that support stochastic transitions, or SINK, a subset of vertices that have zero outdegree and are associated with a payoff in the range [0, 1]. The game starts by …
-
System software techniques to enhance reliability of modern platforms
… value for the minimum tolerable supply voltage (Vmin ). We use benchmarks that vary in terms of application domain, resource utilization and pressure, and software/hardware interaction characteristics to train a Vmin prediction model. Finally, at execution time those metrics are monitored and …
-
Fiabilité et variabilité temporelle des technologies CMOS FDSOI 28-20nm, du transistor au circuit intégré
… des tensions minimums de fonctionnement (Vmin) des mémoires SRAM.
-
Estimation de la pression partielle artérielle du dioxyde de carbone par des paramètres noninvasifs
… comme l’estimation utilisant le volume minute (Vmin) et celle utilisant le gaz carbonique à la fin de l’expiration (PetCO2). Pour ce faire, la base de données implémentée dans l’hôpital Sainte Justine dès mai 2015 a été utilisée. Cette base renferme toutes les données patients dans les soins …
-
Η επίδραση του εκχυλίσματος του καρπού της ελιάς στην καρδιακή λειτουργία και την αρτηριακή σκληρία
… time, DT),Left Atrial (LA) volumes (Vmax, Vp, Vmin) or in most of arterial stiffness parameters (CentralAortic and Pulse Pressure, (cBP-cPP), Augmentation Pressure- (AP) and Augmentation Index-AIx). However, a trend toward reduction in the E/E’ ratio was observed, suggesting a potential …
-
Der Einfluss des elektrischen Remodelings während des akuten und chronischen Myokardinfarktstadiums der Ratte auf das Magnetokardiogramm
… Xmin, Xmax, Ymin, Ymax, die Magnetfeldstärke Vmin, Vmax ) bei. Für die Differenzierung zwischen De- und Repolarisationsänderungen zeigten sich die Zeitintervalle von QRSGesamt (0-20 ms), RSpitze (8-12 ms), STT (20-25 ms) und TEnde (60-70 ms) als geeignet. Parallel zu den MKG-Messungen wurden …
-
Design of innovative solutions to improve the variability and reliability of CMOS circuits on thin film technologies.
… une amélioration des performances de 21X, une Vmin inférieure de 120 mV et une durée de vie de 8X, pour les OPP de faible puissance, de moyenne et de haute performance respectivement.Les études présentées ici ont été incluses dans plusieurs chapitres d'un livre scientifique qui sera publié …
-
Endothelin in the healthy and ischaemic myocardium
… examined. Infusion of ET-1 (0.05 and 0.1 nmol.kg"Vmin" 1) resulted in a significant increase in the total number of ventricular ectopic beats (VEBs), and in beats occurring as ventricular tachycardia (VT). There was a marked increase in the incidence of ventricular fibrillation (VF). Over a range …
-
Non-contact process control sensors for nanoliter dispensing systems
… smallest detectable droplet was identified to be Vmin= 1.5 nl, definig the <br>resolution of the optical sensor. The determination of the droplet velocity <br>could be implemented with an error in accuracy of Δuac= ±0.3 m/s. <br>Additionally, the detection of free flying liquid jets was studied. …
-
Ελαχιστοποίηση όγκου επάλληλου πλανητικού-υδροστατικού μειωτήρα στροφών
… of the optimization model with the algorithm [Vmin].The results obtained are a kind of construction catalogs, to estimate the construction volume of a planetary power gear unit, and are considered satisfactorily, once after having compared with results obtained from previous research works as …
-
Auswirkungen einer experimentellen Infizierung von Kälder mit Mannheimia haemolytica A1 auf Funktionen der äußeren Atmung
… (VT) als auch das Atemminutenvolumen (Vmin) signifikant gegenüber den a.i. ermittelten Werten vermindert, wohingegen die Atmungsfrequenz sich signifikant erhöhte. Zeitgleich verminderten sich folgende mittels IOS erfassten Kenngrößen: die respiratorische Resistance bei 3 Hz, die …
-
Robust, Enhanced-Performance SRAMs via Nanoscale CMOS and Beyond-CMOS Technologies
In this dissertation, a beyond-CMOS approach to Static Random Access Memory (SRAM) design is investigated using exploratory transistors including Tunnel Field Effect Transistor (TFET), Carbon Nanotube Field Effect Transistor (CNFET) and Graphene NanoRibbon Field Effect Transistor (GNRFET). A …