Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 43 for “"Voltage Transformer"”.
-
High Voltage Transformer Bushings: Model To App
Abstract Transformer bushings play a critical role in ensuring the efficient and safe operation of power transformers. Understanding the electrical and thermal behavior of these components is essential for optimizing their design and performance. Therefore the main outline of the thesis is to …
-
Partial discharge signal propagation, modelling and estimation in high voltage transformer windings
… partial discharge (PD) propagation within a high voltage transformer winding. Location of PDs and magnitude estimation are important tools for both diagnosis and prognosis of the health of large transformers. In reality there is limited access and knowledge of a winding and consequently any …
-
Protection of High-Voltage Transformer Bushings and Other Brittle Structures Against Impact
… of the impact behavior of porcelain high-voltage (HV) transformer bushings under high-velocity impact, with a focus on their protection with feasible methods which could be quickly applied in service to prevent vandalism and other undesirable impact situations. The bushings are brittle and …
-
Classification and localisation of multiple partial discharge sources within high voltage transformer windings
… condition monitoring and diagnostics of power transformers, which can be used as a tool for assessing the lifespan of transformers and can detect insulation malfunctions before they lead to failure. This report describes the development of analytical tools for PD activities within HV …
-
Identification of partial discharge sources and their location within high voltage transformer windings
… concerned with developing a new approach to high voltage transformers condition monitoring, which involve partial discharge (PD) measurement and localisation within high-voltage transformer windings. This is an important source of information for both diagnosis and prognosis of the health of power …
-
Risk-Based Performance Assessment of a Seismic Retrofit Technique for Medium- and High-Voltage Transformer Bushing Systems
High voltage electrical transformers bushing systems have exhibited vulnerability during past earthquakes. The enhanced performance of bushings mounted on rigid base observed during shake table testing does not correlate well with their performance in the field. It is suspected that the seismic …
-
Seismic risk assessment of high-voltage transformers using Bayesian belief networks
… earthquake can cause severe damage to high-voltage substations, which may lead to power disruption for a significant amount of time. A high-voltage transformer is one of the key components of a substation. This thesis proposes a probabilistic framework using Bayesian belief network (BBN) …
-
Output Circuits for Cutaneous Muscle Stimulators
… The stimulators were labeled Constant Voltage Transformer Isolated, Constant Current Transformer Amplified, Microstim Plus, and the Constant Current stimulator. The impedance of the human skin under constant current pulses was studied in 10 human subjects, in which the maximum …
-
ELECTRICAL POWER SYSTEM CURRENT AND VOLTAGE INSTRUMENTATION CHANNEL ERROR CORRECTION USING UNCONSTRAINED WEIGHTED LEAST SQUARES DYNAMIC STATE ESTIMATION
… the problem of error generation in the Current Transformer (CT) and Voltage Transformer (VT) Instrumentation Channels, respectively, and then to investigate the application of a Dynamic State Estimation (DSE) technique to correct for the error generation in each case. The dissertation research …
-
Προηγμένες τεχνικές ελέγχου με χρήση μεθόδων βελτιστοποίησης σε έξυπνα δίκτυα ηλεκτρικής ενέργειας με μεγάλη διείσδυση διανεμημένης παραγωγής
… distributed generation penetration to address voltage regulation problems and ensure the optimized network operation, assuming one or more optimization objectives. Initially, a new control technique is presented targeting at the voltage regulation and the minimization of network losses. Its …
-
EM-Taguchi-PSO design optimization of three-phase power transformers
Power Transformers are an essential part of all AC Power Grids. This work proposes a multi-objective design optimization method for Power Transformers to increase efficiency while decreasing core volume in a case study of a step-down transmission-voltage transformer. A Finite-Element State-Space …
-
A Novel Power Supply for Generating a One Atmosphere Uniform Glow Discharge Plasma (OAUGDP®)
<p>A high voltage transformer connected to an atmospheric plasma generator is driven as a current-fed push-pull parallel resonant system, switched by a resonant lamp controller integrated circuit from Texas Instruments (UC3872) in such a manner as to be automatically maintained at resonance. The …
-
The use of a magnetic model to analyze the load dependent behaviour of a power supply
… that power supplies based on the ferroresonant transformer technology are incompatible with certain more recent types of loads such as actively power factor corrected devices. This is an issue that still remains today. The objective of this thesis is to analyze whether a specific ferroresonant …
-
Magnetic augmented rotation system (MARS ) - properties and performance
… 12 volts, a load in the form of a light bulb, a voltage transformer, and digital multimeter to monitor current/voltage in real-time. Additionally, infrared imaging is utilized during charging the rechargeable battery to monitor changes in temperature.
-
Protection system representation in the Electromagnetic Transients Program
… A protection system consists of instrument transformers, relays, and circuit breakers. Models for current transformers and capacitor voltage transformers are developed, validated, and incorporated in EPRI/DCG EMTP Version 2.0. The user can define the values of the current transformer and …
-
Synchronized Phasor Measurement Units Applications in Three-phase Power System
… of power system. By aligning time stamps of voltage and current phasor measurements, which are consistent with Coordinated Universal Time (UTC), a coherent picture of the power system state can be achieved through either direct measurements or simple linear calculations. With the growing …
-
Radiometric partial discharge characterisation
… systems especially in power equipment such as transformers and circuit breakers, the cost of which is very high. Before the insulation fails, there are manifestations of this condition, called partial discharges (PD) and because of this, PD have been subject of an extensive study and …
-
High Speed Distance Relaying Using Least Error Squares Method
… The method is tested using three-phase voltage and current data generated from a PSCAD/EMTDC simulation model. The relay module developed has three functional components: fault detection, phasor estimation, and protective elements. The code for the relay module is developed in MATLAB. …
-
Reliability prediction based on complicated data and dynamic data
… 2, left truncated and right censored high-voltage power transformer lifetime data are available from an energy company. The company wants to predict the remaining life of transformers and the cumulative number of failures at a future time for their transformer fleet. The population is …
Page 1 of 3