Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 447 for “"Voltage clamp"”
-
Insights into Kv1.2 activation and deactivation using voltage clamp fluorimetry
Voltage-gated potassium (Kv) channels are essential membrane proteins in modulating membrane excitability and related cellular processes. Many details associated with the voltage response are unclear, particularly the complete role of the voltage sensing domain, and not just the densely charged S4 …
-
Multiphysics model of a cardiac myocyte: A voltage-clamp study
… coupling for a rat ventricular myocyte under voltage clamp (VC) conditions to: (1) probe mechanisms underlying the response to Ca2+-perturbation; (2) investigate the factors influencing its electromechanical response; and (3) examine its rate-dependent behavior (particularly the …
-
Structural examination of voltage gated potassium channels by voltage clamp fluorometry
Voltage clamp fluorometry (VCF) was first developed in the mid 1990s by Isacoff and his colleagues. In this approach fluorophores are attached to substituted cysteine residues that are engineered by site-directed mutagenesis. Changes in the dielectric environment of the fluorophore report local …
-
Whole-cell Voltage Clamp Of Junctional Conductances In Insect Cell Pairs
… (gate) in response to cellular signals (e.g. voltage), and may be important in regulating cell-to-cell communication in insect development. This thesis presents one of the first biophysical characterizations of GJ channels in insect cell pairs. Double whole-cell voltage-clamp techniques were …
-
A new paradigm for voltage-clamp studies of synthetic ion channels
… to be applicable to these substrates. The voltage-clamp experiment was used to characterize the ion transport properties of these 22 compounds as well as 5 oligo-esters previously prepared by solid-phase synthesis. All but two were active in bilayers, with the majority of these compounds …
-
Der Einfluss lokaler Ionenkonzentrationsänderungen in Membrannähe bei Voltage-Clamp-Messungen am Modellsystem Skelettmuskel
… auf den Stromverlauf bei Voltage-Clamp Experimenten quantitativ zu untersuchen. Als Modellsystem wurde der Skelettmuskel gewählt, wobei zwischen Ca2+-Strömen und K+-Strömen unterschieden wurde, die exemplarisch als Anwendungsbeispiel für physiologisch wichtige Ionenströme …
-
Two-Electrode Voltage Clamp (TEVC) Based Scanning Ion Conductance Microscopy: New Methodology and Validation
… microscopy, confocal microscopy, and patch clamping. A key feature of SICM is its non-invasive scanning ability. The ability to scan samples without coming making contact allows for more robust research in biology. Current SICM techniques call for a one electrode probe, but in this research …
-
A mathematical reconstruction of the frog atrial action potential based on voltage clamp data
… cells have properties which make them ideal for voltage clamp studies. The ionic currents observed under voltage clamp conditons from single frog atrial cells are analyzed with the use of automatic methods programmed on a computer. From the analyzed data, mathematical models are formed which …
-
Étude de changement conformationnel du récepteur alpha-1 à la Glycine par Voltage-Clamp Fluorométrie
… du récepteur à la glycine par la méthode de voltage-clamp fluorométrie (VCF) en marquant le domaine extracellulaire et la région d'interface extracellulaire-transmembranaire par des fluorophores. Le criblage de plusieurs paires de cystéine et de tryptophane aboutit à la découverte de deux …
-
Electrical characteristics of an identified insect motoneurone cell body : a current- and voltage-clamp study
… americana) have been studied under current- and voltage-clamp. 2. Under voltage-clamp depolarising command pulses evoked an outward current which increased with the magnitude of the command step up to approximately +100mV, a component of the current developed more slowly and took longer to reach …
-
Characetritics of transmitter release at a neuromuscular junction : a voltage clamp study of the rat diaphragm
This item was digitized as part of a project to share McGill's intellectual legacy with the public. If you are the copyright holder or a relative of the copyright holder who is deceased, you may request withdrawal by emailing escholarship.library@mcgill.ca. The full policy for eScholarship may be …
-
Influence of a constant magnetic field on the lobster nerve: Conduction velocity and voltage clamp studies.
… potentials and the transmembrane currents under voltage-clamp conditions of the giant axon of this nerve, using the double sucrose gap technique. It was found that within the limitations of these exploratory experiments the conduction velocity, the membrane potentials and the transmembrane …
-
A patch and voltage clamp investigation of the response of the C1 neurone of 'Helix aspersa' to 5-hydroxytryptamine
Application of 5-hydroxytryptamine induces a voltage-dependent inward current in voltage clamped C1 neurones of Helix aspersa. This response has been shown to be the result of a decrease in K conductance and was studied using patch clamp and voltage clamp techniques. Single channel K currents were …
-
Improved voltage clamp fluorometry to investigate the molecular function of the P2X7 receptor C-terminus and characterization of novel P2X7 receptor ligands
… are associated with its activation, I applied voltage clamp fluorometry (VCF) ([4.2]). To this end, I refined a method for the incorporation of the environment-sensitive fluorescent unnatural amino acid (fUAA) ANAP into Xenopus laevis oocyte-expressed receptors. Furthermore, I constructed a VCF …
-
Creating Mechanistic Ion Channel Models Using Genetic Algorithms
… states cannot be directly observed. Myriad voltage clamp protocols have been developed to study these transitions, but model parameterization remains difficult because either all transitions must be culled from one protocol, or the data from multiple protocols must be non-redundantly …
-
Measuring rapid ionic current with a single electrode : a new method for series resistance compensation
… in single cells using a single electrode voltage clamp amplifier (SEVC). The practical limitations inherent with the SEW, primarily the effects of series resistance (R s) which dominate when attempting to record rapid ionic currents, are outlined. The various methods in use to compensate …
-
A study of excitation contraction coupling in rabbit cardiomyocytes
… were subsequently investigated using whole cell voltage clamp. The loading of cardiomyocytes with FURA-2 enabled simultaneous measurement of intracellular calcium concentration. Cardiomyocytes transfected with an adenovirus that caused overexpression of the enzyme beta-galactosidase were employed …
-
Mathematical models of atrial and ventricular myocytes from the rabbit heart
… myocytes that are based on quantitative voltage clamp data from emzymatically isolated cardiac myocytes have been developed. These models are capable of accurately simulating the transmembrane ionic currents recorded in response to a step change in membrane potential (whole-cell voltage …
-
A mathematical model of the mammalian ventricular cell: Mechanistic explanations of long Q-T syndrome
… ventricular cell based on available whole cell voltage clamp data. The model consists of three components: a Hodgkin-Huxley type membrane model describing the electrical activity of the cell membrane; and intracellular fluid compartment model; and a small extracellular cleft space. Material …
Page 1 of 23