Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 139 for “"Voltage measurement"”

  1. High-voltage measurement techniques

    … University of British Columbia acquired a high-voltage test set in 1979 for teaching and research purposes. To make this test set useful for experiments which undergraduate students can do themselves, various additions and modifications had to be made. This thesis describes these additions and …

    ubc Repository record for High-voltage measurement techniques (opens in a new tab)

  2. High-voltage measurement using the quadrature method and permittivity-shielding

    … and permittivityshielding for measuring high voltage using electric field sensors were developed. The quadrature method is a technique that determines the necessary number of sensors that make point-like measurements of the field and the best positioning and weighting of those sensors for any …

    ubc Repository record for High-voltage measurement using the quadrature method and permittivity-shielding (opens in a new tab)

  3. Battery state-of-charge estimation based on open-circuit voltage measurement

    … In this dissertation, the open-circuit voltage (OCV) of the battery will be explored as a parameter to estimate the SOC accurately with the objective to examine the suitability of OCV for the estimation of the SOC of the LFP battery.

    nanyang Repository record for Battery state-of-charge estimation based on open-circuit voltage measurement (opens in a new tab)

  4. Voltage Measurement Using Slab-Coupled Optical Sensors with Polarization-Maintaining and Absorption-Reduction Fiber

    … the use of the Panda-SCOS as means of voltage characterization across both the spark gap of an ignition coil circuit along with the spark gap of an automobile. This paper demonstrates the use of a Panda SCOS to measure the voltages and time delays across the spark gaps at different …

    byu Repository record for Voltage Measurement Using Slab-Coupled Optical Sensors with Polarization-Maintaining and Absorption-Reduction Fiber (opens in a new tab)

  5. Design and Verification of a High Voltage, Capacitance Voltage Measurement System for Power MOSFETs

    There is a need for a high voltage, capacitance voltage (HV, CV) measurement system for the measurement and characterization of silicon carbide (SiC) power MOSFETs. The following study discusses the circuit layout and automation software for a measurement system that can perform CV measurements for …

    vt Repository record for Design and Verification of a High Voltage, Capacitance Voltage Measurement System for Power MOSFETs (opens in a new tab)

  6. Digital one-cycle control technique with grid voltage measurement applied to three-phase power factor corrected rectifiers and active power filters

    … the Digital One Cycle Control (DOCC) with grid voltage measurement to three-phase Power Corrected (PFC) Rectifier and Active Power Filter (APF). The use of grid voltage is explored in a generalized approach, by defining the influence of these measurements on harmonics, power factor and load …

    brazil-uerj Repository record for Digital one-cycle control technique with grid voltage measurement applied to three-phase power factor corrected rectifiers and active power filters (opens in a new tab)

  7. Electrical properties of metal semiconductor contacts - metals on MoS2: a case study

    … Schottky-Mott rules are discussed. The current-voltage measurement and capacitance-voltage measurement are analyzed considering the role of the work function. We mainly focus on metal semiconductor contacts on molybdenum disulfide (MoS2). The properties of bulk and monolayer molybdenum disulfide …

    njit Repository record for Electrical properties of metal semiconductor contacts - metals on MoS2: a case study (opens in a new tab)

  8. Multichannel digital voltmeter using the LM3S8962 evaluation board

    … protects the evaluation board from over/under voltage damage, and biases the incoming voltages to provide usable input voltages for the LM3S8962 ADC inputs. The report begins with an explanation of the goals of the project, and research of what current products exist on the commercial market to …

    texas Repository record for Multichannel digital voltmeter using the LM3S8962 evaluation board (opens in a new tab)

  9. Relaxation and frequency response analysis studies on power equipment

    … of two power-generating plants with Recovery Voltage Measurement (RVM) and Polarization Current Measurement (PCM) techniques and to develop an automated technqiue to identify winding faults and severity of a transformer using Frequency Response Analysis (FRA) technqiue.

    nanyang Repository record for Relaxation and frequency response analysis studies on power equipment (opens in a new tab)

  10. Diamond film growth by microwave plasma enhanced chemical vapour deposition

    … microscopy (AFM) and Raman spectroscopy. Current-Voltage measurement and secondary ions mass spectrometry were being used to verify the presence of boron in the boron-doped diamond film. Silicon (Si) is mainly used as a substrate for the experimental studies.

    nanyang Repository record for Diamond film growth by microwave plasma enhanced chemical vapour deposition (opens in a new tab)

  11. Sensing for Electromechanical Systems

    … In this work, custom instrumentation and measurement schemes are introduced and applied to non-contact voltage measurement, the integrated electronic piezo-electric (IEPE) standard, and cutting tool condition monitoring.

    mit Repository record for Sensing for Electromechanical Systems (opens in a new tab)

  12. Electrical characterization of thin film nanostructure templates

    … with the system are analyzed with capacitance-voltage measurement techniques to provide insight into device operation. Ni is deposited into porous alumina templates to create Ni nanostructures.

    wvu Repository record for Electrical characterization of thin film nanostructure templates (opens in a new tab)

  13. Model and theoretical simulation of solid oxide fuel cells

    … various electrical and electro-chemical measurement experiments, specifically: equilibrium open-circuit cell voltage measurement, cell voltage measurement with increasing dc current density, and electrochemical impedance spectroscopy. The 1-D solid oxide fuel cell system investigated is …

    ohiolink Repository record for Model and theoretical simulation of solid oxide fuel cells (opens in a new tab)

  14. Sphere-Gap Voltage Measurements

    … of a 2 cm. sphere-gap as a standard of high-voltage measurement in the Electrical Engineering Department of the James Watt Laboratories of Glasgow University. Particular study has been made of the procedure necessary to obtain the greatest possible consistency in the results, and to determine …

    glasgow Repository record for Sphere-Gap Voltage Measurements (opens in a new tab)

  15. Low-Power and High Precision Sensing Circuit for a Three-Channel Electrochemical Sensor

    … that can simultaneously handle two current measurements, and one voltage measurement. This work provides a compact, low-power sensor architecture, with the intent for the serial readout to be replaced with a low-power radio frequency transmitter for continuous monitoring. The proposed …

    vt Repository record for Low-Power and High Precision Sensing Circuit for a Three-Channel Electrochemical Sensor (opens in a new tab)

  16. Electrical and thermal analysis of gallium nitride HEMTs

    … the location of HEMT structure that gate voltage measurement relates to. Secondly, we investigated the performance of single pulse and multiple pulses. Thirdly, we studied and compared the performance between the DC model and the Transient model (multiple pulses) with the same power. …

    nps Repository record for Electrical and thermal analysis of gallium nitride HEMTs (opens in a new tab)

  17. High integrated battery monitoring system with active balancing up to ±10A

    … in a targeted manner. This enables the cell voltage to be measured and the flow of energy to or from the cell. This allows the DC/DC converter unit to be used jointly by several accumulator cells connected in series, thereby reducing installation space and costs considerably. While the …

    brazil-ufscar Repository record for High integrated battery monitoring system with active balancing up to ±10A (opens in a new tab)

  18. Enhancement Of The Spin Hall Effect In Platinum/Hafnium Alloy

    … from the adiabatic (low frequency) harmonic Hall voltage measurement, the damping-like spin torque efficiency, which is the lower bound of the spin Hall angle, can be estimated. I demonstrated that the damping-like spin torque efficiency can be increased by over 50% by doping Hf impurity of 1% in …

    cornell Repository record for Enhancement Of The Spin Hall Effect In Platinum/Hafnium Alloy (opens in a new tab)

  19. The active complex electrode (ACE1) electrical impedance tomography system & anatomically inspired modeling of electrode-skin contact impedance

    … complex electrode (ACE1) system for phasic voltage measurement. The ACE1 system was primarily designed for thoracic EIT applications, and its performance and limitations were tested through a variety of experiments. Additionally, the EIT forward problem was used to investigate electrode-skin …

    colostate Repository record for The active complex electrode (ACE1) electrical impedance tomography system & anatomically inspired modeling of electrode-skin contact impedance (opens in a new tab)

Page 1 of 7