Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 160 for “"Voltage pulses"”
-
An electronic timer for high voltage pulses
Thesis (M.S.)--Michigan State College of Agriculture and Applied Science. Dept. of Physics, 1947
-
Partial Discharge Characteristics in Aerospace Applications Under High dv/dt Square-Wave Voltage Pulses
… present a promising solution due to their high voltage capability and rapid switching speed. However, these devices also pose a challenge as their fast switching speed can adversely affect insulation systems. This dissertation aims to investigate and offer a deeper understanding of, as well as …
-
The Modeling of Partial Discharge under Fast, Repetitive Voltage Pulses Using Finite-Element Analysis
… bandgap power modules that can tolerate higher voltages and currents than silicon-based modules are the most promising solution to reducing the size and weight of power electronics systems. These wide-bandgap power modules constitute powerful building blocks for power electronics systems, and …
-
OPTIMIZING SWAP FOR DIRECTED ENERGY – DETECTION OF BURIED CONDUCTORS WITH LOW-ENERGY HIGH-VOLTAGE PULSES
High-voltage directed energy systems have shown promise in the role of neutralizing improvised explosive devices (IEDs) in various experiments over the last decade. While these systems can be very effective with significant benefits over conventional counter-IED techniques, the excessive space, …
-
Molecular Dynamics Simulations to Probe Effects of Ultra-Short, Very-High Voltage Pulses on Cells
… been confined to: (a) low field, long-duration pulses, and (b) focused mainly on electroporation studies. Thus, aspects such as possible field-induced DNA damage, calcium release, alterations in neuro-transmitters, or voltage-gating have generally been overlooked. Ultra-short, high-field pulses …
-
Partial Discharge Characteristics under Square-wave Voltage Pulses with Ultra-short Rise Times under Various Pressures
… advantages, with regards to the operation voltages, switching speeds, operation temperatures, etc. Therefore, compared with the conventional Si device-based VSDs, SiC device-based VSDs would lead to better efficiency and higher power density, which would be beneficial for the success of MEA …
-
Real-Time Measurements on the Effects of Ultra-Short High Voltage Pulses on HL-60 Cells
The application of high voltage microsecond pulses that are above a critical value, to biological cells, has been shown to cause electroporation (Neumann, 1989). In addition, ultra-short pulses of several tens to hundreds of nanoseconds duration have been recently shown to affect intracellular …
-
Investigation of nanostructures on MoS₂ and MoTe₂ produced by voltage pulses from a STM tip and Ar+ and He+ bombardments
… by bombardments with Ar+ and He+ as well as voltage pulses from a tip of STM. Nanostructures were fabricated on natural MoS2 crystals by bombardment with Ar+ and He+ with energies ranging from 100 eV to 5 keV. Ar+ with energies of 100 eV or less remove very few, if any, sulfur atoms from the …
-
Standard measurement system for SI traceable measurement of high voltage pulses up to 500 kV in the nanosecond and sub-nanosecond range
Le travail de cette thèse de doctorat est dédié au développement d'un système de mesure étalon pour assurer la traçabilité SI des hautes puissances pulsées dans le domaine nanoseconde et subnanosecond (HPPNS). Cette traçabilité est nécessaire pour les mesures exactes et précises des formes d'onde …
-
High Voltage Pulse Measurement System
… system to safely and accurately measure high voltage, high frequency pulses in harsh EM environments. High voltage pulses apply to medical, plasma, and food industries. The difficulty of accurately measuring high voltage pulses continues to pose an issue. Measuring high voltage systems can …
-
Synthesis of metal nanoparticles by electrolytical STM and electrochemical discharges
… – (a) double-layer mixing, (b) ultra-short voltage pulses and (c) diffusion governed deposition. Further, Monte Carlo analysis is used to look at cluster formation for the particular case of 2d growth. The mathematical models provide important insights and can be used for optimization. …
-
Investigating Total Charge Liberation From Low Intensity Laser Ablation of Solid Targets
… irradiated metallic surfaces is determined from voltage pulses created when a replacement current neutralizes the ablated surface via a well characterized detection circuit. Repeated measurements are made for a laser beam of a known wavelength, energy, pulse duration, and intensity on target. The …
-
Pulse Power Effects on Transient Plasma Ignition for Combustion
… driven by less than 100 nanosecond, high-voltage pulses, to initiate combustion. The effects of pulse repetition frequency (PRF) and ultrashort nanosecond rise times on TPI are investigated in this work using lean, stoichiometric, and rich air-fuel mixtures at atmospheric pressure. …
-
Energy Recovery Circuits and Cell Characterization for Liquid Crystal Cells
… to opaque with the application of an AC voltage. Existing LC cell drivers do not recover energy, and this is problematic for low-power applications that use batteries. This work presents two energy recovery circuits (ERCs) to extend a smart glass product’s runtime. Using an underdamped, …
-
Experimental Investigation of the Discharge Modes of Nanosecond Pulsed Plasmas at Atmospheric Pressure
… modes driven by both longer and shorter voltage pulses in a needle-to-plate electrode configuration. In addition to the voltage and current waveforms, criteria of the discharge modes were assessed using energy deposition as well as gas temperatures measurement. Under longer voltage pulses …
-
The design and development of fast pulsed power supplies using transmission line transformers
… (>50ns), good quality, high repetition-rate voltage pulses for flash x-ray preionisors and other applications. It explains the principle of the TLT and reports on two TLT pulsed power supplies that have been built. The first, or prototype, produced output voltage pulses with risetimes of 50ns …
-
Artificial electronic synapses based on ferroelectric Hf0.5Zr0.5O2 for neuromorphic applications
… remanent polarization as a function of applied voltage. Finally, it was experimentally confirmed that the injection through the "wake-up" method and trapping of charges into interfacial states that exist due to imperfections, reduces the intensity of the depolarization field, converting …
Page 1 of 8