Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 74 for “"Voltage sags"”
-
Voltage Sags Indices and Statistics
Voltage sag indices are a way of quantifying the performance of the power supply, as far as voltage sags are concerned. Indices can be defined for individual events, for individual sites, and for a whole system. A standard method for single-event methods is part of IEC standard 61000-4-30. This …
-
Voltage sags in power distribution networks
Voltage sags have become increasingly important when considering the various power quality issues that cause inconvenience to customers. For some customers voltage sags cause especially high costs. Thus, power distribution companies should understand the voltage sags experienced in their networks …
-
Mitigating voltage sags by optimal placement of series compensation devices using genetic algorithm
… provide the most economical solution to voltage-sag problems. Distributed mitigation with strategically placed compensation devices should provide a better alternative. Placement studies of this nature usually involve extensive evaluations of candidate compensation schemes, which can …
-
Using PMU and PQ monitor for voltage sag extended-characterization
… For example, rolling mills are sensitive to voltage disturbances, due to the use of converter drive systems, which trip due to voltage sags. Voltage sag (dip) is one of the most severe power quality problems. The root cause of voltage sag is a short circuit in the power system, e.g., due to …
-
Modeling of the dynamic voltage restorer in EMTP
The dynamic voltage restorer (DVR) is a power electronic device that is used in power transmission and distribution systems to protect consumers from sudden voltage sags and swells in the grid voltage. This thesis presents a comprehensive model of a DVR using the EMTP simulation software. The model …
-
ASSESSMENT AND ALLEVIATION OF VOLTAGE SAG-INDUCED ECONOMIC LOSSES IN MODERN INDUSTRIAL DISTRIBUTION SYSTEM
… (VFD). PV and VFD could be used to ride through voltage sags and prevent costly load interruption. Hence, this thesis first proposes a method to assess annual economic loss for an industrial network consisting of PV and dynamic loads due to probable voltage sag events. Secondly, the proposed …
-
Topologia de gerador de distúrbios elétricos baseada em conversores de potência
Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the …
-
Afundamentos de tensão em consumidores industriais : uma análise baseada no fator de impacto e na severidade dos eventos considerando os efeitos de faltas elétricas em sistemas de potência
… of Electrical Regulation, within the scope of voltage sags. For such comparison, a case study of monitoring is performed on an industrial consumer sensitive to the disturbance during 24 months. Additionally, since the main causes of the voltage sags are the electrical faults of the system to …
-
Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível
… to electrical disturbances, especially voltage sags since the stator is directly connected to the grid. This feature highlights a fundamental challenge which is to provide fault support. Given this problem’s relevance, this thesis proposes improving DFIG supportability to a voltage sag …
-
Optimal placement of dynamic voltage restorers and static synchronous compensators for enhancing power quality
… stable operation. Among various disturbances, voltage sags pose serious risks to industrial processes, often resulting in equipment malfunction or production losses. This study investigates dynamic voltage restorers (DVRs) and static synchronous compensators (STATCOMs) as PQ issue mitigation …
-
Voltage sag source location in power systems
… study of available methods for locating voltage sag sources in power systems. The performance of four sag source location methods is analyzed by simulating faults in a Brazilian transmission network using PSCAD/EMTDC. The most reliable methods (distance relay, reactive power and slope of …
-
Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage
… FRT capability, reactive power injection during voltage sags and power quality. From the GCPPP side, the main reasons for inverter disconnection are: loss of synchronization, excessive ac currents, excessive dc voltage, and voltage rise in non-faulty phases under unbalanced voltage sags due to …
-
On-line Dynamic Security Assessment in Power Systems.
… in synchronism, it is also required that the bus voltages remain within acceptable limits. A transient disturbance and the following angular divergence of a group of generators can cause critical voltage sags at certain buses in the system. In this thesis assessment of such voltage sags is …
-
Analyzing voltage sag direction using protective relays and deep-learning methods
… to study methods of identifying the direction of voltage sags in the distribution circuits. Voltage sags arise from the presence of short-circuit faults involving single, double, and three phase-to-ground conditions. The direction of the fault is based on the direction of power flow before the …
-
Voltage support in open pit mining power systems using electric drill rigs
… capacity and increased susceptibility to voltage instability. High-power induction motor startups in drilling equipment frequently generate significant voltage sags, that compromise operational continuity and compliance with power quality standards. This thesis examines different …
-
Voltage support in open pit mining power systems using electric drill rigs
… capacity and increased susceptibility to voltage instability. High-power induction motor startups in drilling equipment frequently generate significant voltage sags, that compromise operational continuity and compliance with power quality standards. This thesis examines different …
-
A Fault Tolerant 3-Phase Adjustable Speed Drive Topology with Common Mode Voltage Suppression
… to semiconductor device faults b) input voltage sags c) motor vulnerability to effects of long leads and d) achieve active minimization of common mode (CM) voltage applied to the motor terminals. These objectives are attained by inclusion of an auxiliary IGBT inverter leg, three auxiliary …
-
Βελτίωση της ικανότητας αδιάλειπτης λειτουργίας Α/Γ με μετατροπείς ισχύος σε σφάλματα δικτύων διανομής μέσω της χρήσης υπερπυκνωτών
… the ability of WTGs to ride-through faults and voltage sags, by employing supercapacitor ESS. Two types of variable speed wind turbines generators are examined; the direct driven full-converter generators and the doubly-fed induction generators (DFIGs) with partially rated power converter …
-
Protection of Grid-Tied and Islanded Systems with High Penetration of Inverter-Based Resources
… the short-circuit contribution of a generic voltage source converter. The proposed design allows the inverter to provide sustained short-circuit current to achieve fuse-relay and relay-to-relay coordination. Adaptive relaying for microgrid protection in islanded and grid-tied mode is …
Page 1 of 4