Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 281 for “"Voltage-Clamp"”.
-
Insights into Kv1.2 activation and deactivation using voltage clamp fluorimetry
Voltage-gated potassium (Kv) channels are essential membrane proteins in modulating membrane excitability and related cellular processes. Many details associated with the voltage response are unclear, particularly the complete role of the voltage sensing domain, and not just the densely charged S4 …
-
Multiphysics model of a cardiac myocyte: A voltage-clamp study
… coupling for a rat ventricular myocyte under voltage clamp (VC) conditions to: (1) probe mechanisms underlying the response to Ca2+-perturbation; (2) investigate the factors influencing its electromechanical response; and (3) examine its rate-dependent behavior (particularly the …
-
Structural examination of voltage gated potassium channels by voltage clamp fluorometry
Voltage clamp fluorometry (VCF) was first developed in the mid 1990s by Isacoff and his colleagues. In this approach fluorophores are attached to substituted cysteine residues that are engineered by site-directed mutagenesis. Changes in the dielectric environment of the fluorophore report local …
-
A new paradigm for voltage-clamp studies of synthetic ion channels
… to be applicable to these substrates. The voltage-clamp experiment was used to characterize the ion transport properties of these 22 compounds as well as 5 oligo-esters previously prepared by solid-phase synthesis. All but two were active in bilayers, with the majority of these compounds …
-
Two-Electrode Voltage Clamp (TEVC) Based Scanning Ion Conductance Microscopy: New Methodology and Validation
… microscopy, confocal microscopy, and patch clamping. A key feature of SICM is its non-invasive scanning ability. The ability to scan samples without coming making contact allows for more robust research in biology. Current SICM techniques call for a one electrode probe, but in this research …
-
A mathematical reconstruction of the frog atrial action potential based on voltage clamp data
… cells have properties which make them ideal for voltage clamp studies. The ionic currents observed under voltage clamp conditons from single frog atrial cells are analyzed with the use of automatic methods programmed on a computer. From the analyzed data, mathematical models are formed which …
-
Influence of a constant magnetic field on the lobster nerve: Conduction velocity and voltage clamp studies.
… potentials and the transmembrane currents under voltage-clamp conditions of the giant axon of this nerve, using the double sucrose gap technique. It was found that within the limitations of these exploratory experiments the conduction velocity, the membrane potentials and the transmembrane …
-
Improved voltage clamp fluorometry to investigate the molecular function of the P2X7 receptor C-terminus and characterization of novel P2X7 receptor ligands
… are associated with its activation, I applied voltage clamp fluorometry (VCF) ([4.2]). To this end, I refined a method for the incorporation of the environment-sensitive fluorescent unnatural amino acid (fUAA) ANAP into Xenopus laevis oocyte-expressed receptors. Furthermore, I constructed a VCF …
-
Creating Mechanistic Ion Channel Models Using Genetic Algorithms
… states cannot be directly observed. Myriad voltage clamp protocols have been developed to study these transitions, but model parameterization remains difficult because either all transitions must be culled from one protocol, or the data from multiple protocols must be non-redundantly …
-
A study of excitation contraction coupling in rabbit cardiomyocytes
… were subsequently investigated using whole cell voltage clamp. The loading of cardiomyocytes with FURA-2 enabled simultaneous measurement of intracellular calcium concentration. Cardiomyocytes transfected with an adenovirus that caused overexpression of the enzyme beta-galactosidase were employed …
-
Mathematical models of atrial and ventricular myocytes from the rabbit heart
… myocytes that are based on quantitative voltage clamp data from emzymatically isolated cardiac myocytes have been developed. These models are capable of accurately simulating the transmembrane ionic currents recorded in response to a step change in membrane potential (whole-cell voltage …
-
A mathematical model of the mammalian ventricular cell: Mechanistic explanations of long Q-T syndrome
… ventricular cell based on available whole cell voltage clamp data. The model consists of three components: a Hodgkin-Huxley type membrane model describing the electrical activity of the cell membrane; and intracellular fluid compartment model; and a small extracellular cleft space. Material …
-
A model of the rate dependence of the atrial action potential in rabbit
… current descriptions incorporate whole-cell voltage-clamp data from enzymatically isolated rabbit cardiomyocytes, and account for the reactivation timecourse of the largest ionic currents. Our model can simulate both the whole-cell voltage-clamp data upon which it is based and the …
-
ION CHANNELS PATHOPHYSIOLOGY AND BIOPHYSICS:1. THE ROLE OF THE EXPRESSION OF CLIC1 ION CHANNELS IN CANCER STEM CELLS FROM HUMAN GLIOBLASTOMA; 2. CA2+ AND VOLTAGE DEPENDENT STRUCTURAL CHANGES IN THE HUMAN BK CHANNEL DURING OPERATION REVEALED BY VOLTAGE CLAMP FLUOROMETRY.
… Channel 1 (CLIC1) and the large conductance Ca2+-voltage activated K+ channel (BK). The goal of the first project aimed to understand the role of CLIC1 channels in glioblastoma cancer stem cells. Among brain tumors, glioblastomas are very frequent and have the worst outcome. They are composed of …
-
Characterization of Phosphatidylinositol 4,5-bisphosphate Regulation of the Electrogenic Na/Bicarbonate Cotransporter NBCe1
… by ~150% as monitored by the two-electrode voltage-clamp technique. The majority of this stimulation required PIP2 hydrolysis to IP3 and ER Ca2+ stores, and was mediated by a staurosporine-sensitive kinase. The second study focuses on the effect of PIP2 itself on the activity of NBCe1 …
-
Voltage Dependent Ion Transport by Bolaamphilphilic Oligoester Ion Channels
… using a planar bilayer experiment with the voltage-clamp technique. The main structures of these compounds are identical, consisting of a mono or tri-aromatic core, two octamethylene chains and two benzoyl headgroups which are all connected through ester linkages. The structural variance was …
-
Mathematical modeling of the sinoatrial node cell in the rabbit heart
… is based on experimental results from whole-cell voltage clamp and action potential studies on single enzymatically-isolated pacemaker cells. The model consists of two parts, a model of sarcolemma, and a fluid compartment model of the intra and extracellular media. The sarcolemmal membrane model …
-
Simulace průběhu akčních napětí a membránových proudů řešením zobecněných rovnic Hodgkina a Huxleye
… membránových proudů ve dvou základních režimech (voltage clamp a current clamp). Vše v prostředí MATLAB GUI.
-
Simulace elektrofyziologických experimentů
… Program obsahuje základní měřící metody current clamp a voltage clamp s možností měnit základní parametry modelu. Výsledky této práce jsou poté srovnány s dostupnou literaturou.
Page 1 of 15