Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 69 for “"Voltmeter"”.
-
A/D conversion: a digital voltmeter
… available today is the Fairchild 381^ Digital Voltmeter Logic Array which contains most of the logic required for a 4 1/2 decade digital Voltmeter. In this thesis the design of an inexpensive four digit, auto-scaling digital voltmeter is presented with results of tests performed on this meter.
-
Multichannel digital voltmeter using the LM3S8962 evaluation board
… demonstrates a useful and flexible 4-channel voltmeter using an LM3S8962 Evaluation Board, and commodity electronic components to serve as a shield circuit. The shield circuit protects the evaluation board from over/under voltage damage, and biases the incoming voltages to provide usable input …
-
A Generating Voltmeter of Wide Sensitivity Range for Measuring Atmospheric Potential Gradients
The specific need for the present instrument arose out of a consideration of the significant results that might be obtained through a coordination of reliable data on potential gradients under various cloud formations with the accompanying fast motion cloud photographs. The characteristics most …
-
Design and construction of a kilo-voltmeter for use with x-ray machines
Thesis (M.S.)--Michigan State University. Dept. of Physics, 1935
-
The design, construction, and calibration of a generating voltmeter for a two million volt electrostatic accelerator
A generating voltmeter capable of measuring one, two, or found million volts has been designed and constructed for use with the Virginia Polytechnical Institute electrostatic accelerator. The voltmeter is a grounded shutter type, the rectified output of which is measured by a vacuum tube voltmeter. …
-
Computer-assisted mass spectrometry and its application to rubidium-strontium geochronology
… described. The system employs a digital voltmeter at the mass spectrometer for analog-digital conversion of the ion beam. The "conversion complete" signal from the voltmeter is used to interrupt the computer. At each interrupt, the computer reads the mass spectrometer, filters the …
-
Construction and Testing of a Charging System and a Corona Column for an Electrostatic Accelerator
… University. Calibration data of the generating voltmeter to be used for determining the potential developed by the generator are also included in the paper.
-
Relevant and irrelevant auditory backgrounds during visual monitoring.
… detection of an abnormally large deflection of a voltmeter needle making twenty uniform deflections per minute. The length of the watch was sixty minutes, during which thirty-two signals were presented. Twenty-four military officers were used as subjects, eight in each group. A statistical …
-
Application of prussian blue in developing catalase inhibition-based cyanide ion biosensor /
… of a solute in solution. A high-impedance voltmeter is used to detect the potential between two electrodes in this technique. There can be applied to methods for the purpose of work. The first one is cyclic voltammetry for the sustainable deposition of Prussian blue and its stabilization. …
-
Survey of basic analog multiplication techniques and investigation of a correlation noise reduction circuit using a modern monolithic multiplier
… of RMS values, when compared to a true RMS voltmeter, for input signals in the frequency range from 100 Hertz to 50 kilo-Hertz. Also, the system effectively reduced uncorrelated "noise" additions whose RMS values were equal to or less than that of the input.</p>
-
A semi-automatic LVDT testing system
… laser interferometer, and a digital phase angle voltmeter to make the measurements which are necessary to test an LVDT. Software was also written to provide the necessary program control and data analysis.</p><p>The system was tested using a "quasi-LVDT" which was composed of a phase reversal …
-
Bioelectric potentials and active transfer in frog skin
The vibrating probe voltmeter for the measurement of bioelectric potentials by Bluh and Scott has been used in an improved form for measurements of frog skin potential differences. In good agreement with earlier findings the observed frog skin potential differences were found to be of the order of …
-
Automatic data acquisition system for an LED test
… a l6-bit Relay Output Register and a digital voltmeter for data acquisition and transmission. Special purpose assembly language input/output routines were written for the computer's BASIC Interpreter to make this special equipment accessible to the computer. The Control program handled data …
Page 1 of 4