Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"Volume indices"”
-
Investigation of Respiratory Motion Management Techniques For Proton and Photon Radiotherapy of Lung Cancer
… patients. The mean changes in normal tissue dose-volume indices were indistinguishable except proton therapy had a greater increase in lung V5, heart V5 and spinal cord maximum dose. The effects of respiratory motion on the calculated dose were not correlated to the tumor motion. The second aim …
-
The immediate price and volume effects of investment advisory services on stocks recommended
… study was to investigate the immediate price and volume effects or investment advisory services on stocks recommended. The methodology used in this study consisted of the selection of sixty-four stock recommendations published by three major advisory services, Value Line Investment Service, …
-
Microscopic evaluation of activated sludge from eleven wastewater treatment plants in Cape Town, South Africa
… findings. Fl values of >3 and dissolved sludge volume indices (DSVI's) of >150 were chosen as representing the possibility of bulking conditions being present. The five most prevalent dominant filaments were Type 0092, Type 1851, actinomycetes, Microthrix parvicella and Type 021N, being present …
-
Examination of the Fouling and Treatment Performance of a Hybrid Membrane Bioreactor for Decentralized Greywater Reclamation
… of their sludge. The di erences in the sludge volume indices of each bioreactor were strongly correlated to the lling ratio and moderately correlated to the improvements in operating time. An analysis of the permeate indicated that the HMBR was able to achieve greater reductions in nitrogen …
-
A study of errors for 4D lung dose calculation
… of DME on the MLD, lung V20, and Esophagus volume indices. Statistically, MLD and lung V20 DME were significant. Two patients had D98 Pinnacle-DME of 4.4 and 1.2 Gy. In high dose gradient regions DVF spatial accuracy of ~ 1 mm is needed while 8 to 10 mm DVF accuracy can be tolerated before …
-
Carbon Dioxide Pneumoperitoneum and Laparoscopic Ovariectomy in the Domestic Rabbit (Oryctolagus cuniculus)
… (ABP); cardiac output, cardiac and stroke volume indices (CI, SVI); heart rate; end-tidal CO2 (ETCO2); blood gases (PaCO2, PaO2); peak inspiratory pressure (PIP); and peripheral oxygen saturation (SpO2). Heart rate, SpO2, and ABP were unaffected by IAP. For PaO2, an interaction effect was …
-
Aerobic treatment of CTMP wastewater in sequencing batch reactors
… mg/I at the end of 24-hour cycles, and Sludge Volume Indices ranged from 54 to 78 ml/g (for reactors without pH adjustment). Sludge yields in the 24-hour cycle runs were about 0.12 kg MLVSS per kg COD removed, and 0.15-0.18 kg MLVSS per kg BOD₅ removed. This is only about one quarter the sludge …
-
Plan Quality and Isotoxic Dose Escalation Investigation Using a 0.35T MR-Linac System in Ablative 5-Fraction Stereotactic Magnetic Resonance-Guided Radiation Therapy (MRgRT) for Primary Pancreatic Cancer
… index (CI) and the ratio of the 50% isodose volume to PTV (R50%) conformity metrics were calculated for all 45 MRL plans, in addition to standard dose-volume indices. 45 MR-Linac plans were created which met their respective dosimetric criteria described above. For Plan 1, the MR-Linac TPS …
-
Evaluation de la qualité des modèles 3D de bâtiments en photogrammétrie numérique aérienne
… que nous proposons se penche sur le calcul d'indices de qualité fréquemment rencontrés dans la littérature. L'originalité de notre approche réside dans le fait que les modèles employés en entrée ne se limitent pas au mode raster, mais s'étendent au mode vecteur. Il semble évident que les …