Modelagem computacional de um acelerador linear e da sala de radioterapia para cálculo da dose efetiva em pacientes submetidos a tratamento de câncer de próstata
… The modeling was used with an anthropomorphic voxel phantom to calculate absorbed doses in organs and tissues of a patient undergoing a three dimensional conformational radiotherapy protocol. Finally, additional steel and lead shielding added to the primary belt of the radiotherapy room were …
-
Discrete ordinates CT organ dose simulator (DOCTORS)
… a spatially distributed dose profile from a CT voxel phantom. This work proposes a new code, Discrete Ordinate CT Organ Dose Simulator (DOCTORS) which utilizes a GPU accelerated raytracer and discrete ordinate solver to compute photon flux in the patient. The flux is then converted to …
-
Remodelagem do sistema computacional para dosimetria em radioterapia por nêutrons e fótons baseado em métodos estocásticos - SISCODES
… The SISCODES provides tools to build a patient's voxels model, to define a treatment planning, to simulate this planning, and to view the results of the simulation. The SISCODES implements a database of tissues, sources and nuclear data and an interface to access then. The graphical SISCODES …
-
Δοσιμετρία με Monte Carlo προσομοίωση σε εξετάσεις μαστογραφίας με ψηφιακές και τομογραφικές τεχνικές
… sizes and glandularities using a realistic voxel phantom.Under auto-exposure conditions (AEC) the MGD was found to range from 0,306mGy to 2,738mGy for CC view and from 0,352mGy to 3,113mGy for MLO view in CEDM mode. The dose contribution analysis of each projection for all voxel phantom …
-
A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination.
… measurement time. Three different computational phantoms were considered for this work: the adult male Bottle Mannequin Absorber (BOMAB) phantom, the University of Florida – Oak Ridge National Laboratories (UF-ORNL) stylized phantom, and the International Commission on Radiological Protection …
-
A novel Monte-Carlo based method of calculating mean transit time through voxelized biological organs
… blood flow simulation using computational human phantoms (CHP), a potential novel use of capillary transit time analysis in the field of internal and external dosimetry has arisen, where it may be used to predict the distribution of dose imparted by the radiophermaceuticals and the distribution …
-
Wearable antennas: design, connectivity and evaluation measurement techniques
… measurements, a novel design of a liquid torso phantom and a new methodology for evaluating wearable antenna performance by using the cylindrical near field measurement technique are proposed. As for the textile antennas and transmission lines feeding and interconnecting, two novel methods are …