Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 80 for “"W/C ratio"”

  1. Investigating the Influences of Ingredients, W/C Ratio and Dispersion Methods for CNT Modified Smart Concrete

    … This study investigates how the ingredients, W/C ratio and dispersion methods influence the sensing ability of the smart concrete. Three different dispersion methods were investigated: direct mixing, surfactant surface treated with NaDDBS, and the Carboxymethyl cellulose (CMC) surface …

    ndsu Repository record for Investigating the Influences of Ingredients, W/C Ratio and Dispersion Methods for CNT Modified Smart Concrete (opens in a new tab)

  2. An investigation of the low temperature properties of plain and reinforced concrete slabs.

    … concrete is 2.44 x 10-6 per degree F for w/c ratio 0.708 and 3.43 x 10-6 per degree F for w/c ratio 0.434. For reinforced concrete with 5.5% steel these values are 3.82 x 10 -6 per degree F for w/c ratio 0.708 and 4.68 x 10-6 per degree F for w/c ratio 0.434. Above freezing point of water the …

    ottawa-retro Repository record for An investigation of the low temperature properties of plain and reinforced concrete slabs. (opens in a new tab)

  3. Self-Consolidating Concrete for Box Culverts in South Dakota Using Local Aggregates

    … four base mix designs, the water/cement (w/c) ratio was varied. The w/c ratio values were 0.38, 0.42, and 0.46 for the mixes tested. The fresh concrete tests performed on the SCC evaluated flowability, passing ability, and segregation resistance. The hardened concrete tests performed measured …

    sdstate Repository record for Self-Consolidating Concrete for Box Culverts in South Dakota Using Local Aggregates (opens in a new tab)

  4. Ternary combination concretes using GGBS, fly ash & limestone: strength, permeation & durability properties

    … cost.<br/>The mixes covered a range of w/c ratios (0.35. 0.50 and 0.65), which was the main basis of comparison, and combinations of CEM I with GGBS (at levels of 35%, 55% and 75%), and fly ash and LS part-replacing this (at levels of 10 to 20 % and 10 to 35% respectively), after …

    dundee Repository record for Ternary combination concretes using GGBS, fly ash & limestone: strength, permeation & durability properties (opens in a new tab)

  5. Low Cycle Fatigue Behavior of Concrete with Recycled Concrete Aggregates

    … material variables are the water to cement (w/c) ratio, taken as 0.60, 0.45, and 0.39, and percent coarse recycled concrete aggregate content, varied from zero to 100 percent. The primary testing variable is the specified unloading strain. Unloading strains include 60, 75, 90, 100, and 120 percent …

    calpoly Repository record for Low Cycle Fatigue Behavior of Concrete with Recycled Concrete Aggregates (opens in a new tab)

  6. Evaluation of Multiple Corrosion Protection Systems for Reinforced Concrete Bridge Decks

    … 222+, and Hycrete DSS) in concrete with a w/c ratio of 0.45 and 0.35, an ECR containing a primer of microencapsulated calcium nitrite between the epoxy and the steel in concrete with a w/c ratio of 0.45 and 0.35, three types of increased adhesion ECR (ECR pretreated with chromate prior to the …

    ku Repository record for Evaluation of Multiple Corrosion Protection Systems for Reinforced Concrete Bridge Decks (opens in a new tab)

  7. Effects of Curing Time and Curing Temperature on the Standard Test for Strand Bond

    … results. The pull-out forces increase as the w/c ratio of the mixture (decreased curing time) decreases for mixtures of the same mortar strength. In addition, the pull-out values increase as the curing temperature increases for mixtures of the same mortar strength. Interestingly, the STSB method …

    okstate Repository record for Effects of Curing Time and Curing Temperature on the Standard Test for Strand Bond (opens in a new tab)

  8. The Effect of Fly Ash Chemical Composition on Compressive Strength of Fly Ash Portland Cement Concrete

    … found that the new Selected model measuring w/c ratio, w/c ratio, LOI, and the bulk percentage of six metal oxides, was better able to predict concrete 28-day strength. It finds that the current ASTM limits for fly ash are insufficient to fully explain the strength of concrete utilizing fly ash …

    ohiolink Repository record for The Effect of Fly Ash Chemical Composition on Compressive Strength of Fly Ash Portland Cement Concrete (opens in a new tab)

  9. Pore structure and oil flow through hardened cement paste, mortar and concrete

    Increased oil exploration necessitates building of conc~ete structures for its production and storage. The effects of crude oil on concrete properties are not well known and little data is available in the published works. This investigation covers HCP, mortar and concrete. First, it studies the …

    whiterose Repository record for Pore structure and oil flow through hardened cement paste, mortar and concrete (opens in a new tab)

  10. Predicting and testing the tensile relaxation of concrete

    … two. The parameters investigated include: w/c ratio, age of loading, initial stress-strength ratio and aggregate content. Tensile relaxation tests are difficult to perform and hence prediction models are often relied upon to predict relaxation. Two simplified approximate methods are suggested …

    cape-town Repository record for Predicting and testing the tensile relaxation of concrete (opens in a new tab)

  11. Moisture Conditions and Frost Resistance of Concrete in Hydraulic Structures

    … may have a considerable impact on the deterioration of concrete. Both superficial and internal damage, which are suspected to have been caused by frost action, have been found in concrete in hydraulic structures. These observations have raised questions about the long-term behaviour of …

    lund Repository record for Moisture Conditions and Frost Resistance of Concrete in Hydraulic Structures (opens in a new tab)

  12. Role of cement content in determining resistance of concrete to reinforcement corrosion

    … of published literature shows that at fixed w/c ratio, cement reduction is not detrimental to fresh and hardened concrete properties and may improve performance in some cases. However, cement content variations (in some cases) are relatively small and do not cover an adequate range around the …

    dundee Repository record for Role of cement content in determining resistance of concrete to reinforcement corrosion (opens in a new tab)

  13. Characterization and deterioration detection of portland cement concrete using ultrasonic waves

    … Portland cement concrete (PCC), to detect deterioration induced by freeze/thaw and alkali-silica reaction, and to detect chloride presence in PCC using ultrasonic waves. The experimental program was initiated to investigate the effect of water to cement (w/c) ratio, aggregate type, and air …

    vt Repository record for Characterization and deterioration detection of portland cement concrete using ultrasonic waves (opens in a new tab)

  14. Enhancing the service life of concrete exposed to chloride attack

    … as addition to form ternary concretes. The w/c ratio of concrete was selected in the range of 0.35 to 0.45 for the requirement of high performance. To improve the degree of accuracy, four contemporary chloride test methods were used in this work to measure the chloride penetration of concrete, …

    dundee Repository record for Enhancing the service life of concrete exposed to chloride attack (opens in a new tab)

  15. Chloride initiated reinforcement corrosion in marine concrete

    … tests. Factors affecting the chloride penetration into concrete were also investigated by means of field tests. The thesis consists of a summary (86 p.) and 11 papers attached. Measured total chloride thresholds for uncracked concrete based on sulfate resisting portland cement with w/c ratio …

    lund Repository record for Chloride initiated reinforcement corrosion in marine concrete (opens in a new tab)

  16. Developing a prism qualification test to ensure adequate splitting resistance in pretensioned concrete railroad ties

    … mixtures with a water-to-cementitious (w/c) ratio 0.32 were used for all castings except one test where a 0.38 w/c ratio was used. For compressive release strength 12000 psi a 0.26 w/c ratio was used, and desired strength was achieved after 6 days. Concrete-to-steel reinforcement ratios and …

    ksu Repository record for Developing a prism qualification test to ensure adequate splitting resistance in pretensioned concrete railroad ties (opens in a new tab)

  17. Modeling steel corrosion failure in reinforced concrete canisters (RMCCs) containing low-level radioactive waste (LLRW)

    … of steel corrosion by chlorides. Chloride concentrations in the LLRW will eventually make contact with the RMCC’s walls and will diffuse through concrete’s relatively porous network. Varying the mix designs between different cementitious materials, its water-to-cement (w/c) ratio, temperatures, …

    texas Repository record for Modeling steel corrosion failure in reinforced concrete canisters (RMCCs) containing low-level radioactive waste (LLRW) (opens in a new tab)

  18. The influence of PVA fibres on microstructure and mechanical properties of foam concrete

    … behaviour of foam concrete. A higher w/c ratio was found to correlate with superior fibre distribution, enhanced pore distribution, and larger pores – indicative of an elevated pore wall thickness – within the foam concrete. It was observed that 0.45 was the optimal w/c ratio due to the …

    unsw Repository record for The influence of PVA fibres on microstructure and mechanical properties of foam concrete (opens in a new tab)

  19. Effect of Surface Moisture Condition on Substrate-Repair Concrete Overlay Transition Zone

    … reducing the local water-to-cement (w/c) ratio in the OTZ. Conversely, if the substrate is too wet, then the w/c ratio of the OTZ will be locally increased. In both scenarios, the interfacial bond strength is expected to be modified due to the change in the local w/c ratio. To understand …

    vt Repository record for Effect of Surface Moisture Condition on Substrate-Repair Concrete Overlay Transition Zone (opens in a new tab)

  20. Drying Shrinkage Performance of Slabs-on-Grade Reinforced with Recycled Tyre Steel Fibres

    … uses readily available quantities (namely w/c ratio and concrete maturity) as primary material modelling parameters to investigate the effects of pore relative humidity and ambient temperature on the diffusivity properties of concrete using inverse numerical analysis. As a result, a diffusion …

    whiterose Repository record for Drying Shrinkage Performance of Slabs-on-Grade Reinforced with Recycled Tyre Steel Fibres (opens in a new tab)

Page 1 of 4