Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"WAMPAC"”.

  1. Communication network design and evaluation for WAMPAC in smart grid

    A Wide Area Measurement, Protection and Control (WAMPAC) strategy offers great potential for the upgrade of the supervision, operation, protection and control of modern power systems. Forwarding high volume measurements as well as timecritical protection and control signals across a national area …

    strathclyde Repository record for Communication network design and evaluation for WAMPAC in smart grid (opens in a new tab)

  2. Measurements for Wide Area Monitoring, Protection, and Control systems: algorithms, instruments and architectures

    … Wide Area Monitoring, Protection, and Control (WAMPAC) systems have emerged as a critical solution to enhance the real-time observability and responsiveness of modern power grids. WAMPAC systems take advantage of synchronized measurement networks to provide a comprehensive view of grid dynamics …

    cagliari Repository record for Measurements for Wide Area Monitoring, Protection, and Control systems: algorithms, instruments and architectures (opens in a new tab)

  3. Attack-resilient state estimation and testbed-based evaluation of cyber security for wide-area protection and control

    … wide-area monitoring, protection, and control (WAMPAC) applications. The first component, 'Attack-Resilient State Estimation,' addresses the vulnerability of state estimation to stealthy cyber attacks, and discusses two complementary approaches to enhance its resilience. A topology-based attack …

    iastate Repository record for Attack-resilient state estimation and testbed-based evaluation of cyber security for wide-area protection and control (opens in a new tab)

  4. Cyber-security enhancement of wide-area monitoring, protection, and control systems

    Wide-area monitoring, protection and control (WAMPAC) systems have emerged as a promising solution to improve situational awareness of power grid operators. WAMPAC systems collect system-wide measurements through communication infrastructure, synchronize using global positioning system (GPS) in …

    concordia Download PDF for Cyber-security enhancement of wide-area monitoring, protection, and control systems (opens in a new tab)

  5. Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

    … Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation …

    iastate Repository record for Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids (opens in a new tab)

  6. Cascading Outages Detection and Mitigation Tool to Prevent Major Blackouts

    … of Wide Area Monitoring, Protection and Control (WAMPAC) systems. Availability of common measurement time reference as the fundamental requirement of WAMPAC system is attained by introducing the Phasor Measurement Units, or PMUs that are taking synchronized measurements using the GPS clock signal. …

    tamu Repository record for Cascading Outages Detection and Mitigation Tool to Prevent Major Blackouts (opens in a new tab)

  7. Cyber-Physical Security of Wide-Area Frequency-based Applications in Power Systems

    … of Wide-Area Monitoring, Protection and Control (WAMPAC), a new kind of advanced scheme based on wide-area measurements. The blackouts happening in North America as well as in other countries over the past few years are also providing more incentives to scientists and engineers to study wide-area …

    waterloo Repository record for Cyber-Physical Security of Wide-Area Frequency-based Applications in Power Systems (opens in a new tab)

  8. IEC 61850 BASED GOOSE AND SV SERVICES FOR WIDE-AREA PROTECTION AND AUTOMATION

    … Wide-Area Monitoring Protection and Control (WAMPAC). Existing phasor and frequency estimation algorithms in PMUs lack the ability to reflect dynamic changes in network and are slower for fast protection applications due to low reporting rates of the phasors and centralized PDC architectures …

    mtu Repository record for IEC 61850 BASED GOOSE AND SV SERVICES FOR WIDE-AREA PROTECTION AND AUTOMATION (opens in a new tab)

  9. The Virginia Tech Phasor Data Concentrator Analysis & Testing System

    … Measurement, Automation, Protection and Control (WAMPAC) has lead to the substantial increase in the development and use of Synchrophasor Systems. The Department of Energy having realized its importance in the Power System has encouraged its deployment through the Smart Grid Investment Grant. With …

    vt Repository record for The Virginia Tech Phasor Data Concentrator Analysis & Testing System (opens in a new tab)

  10. Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

    … wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and …

    iastate Repository record for Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids (opens in a new tab)