Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 40 for “"WLI"”
-
Development of Tunable Optical Filters for Interrogation of White-Light Interferometric Sensors
… low-cost, to current white-light interferometry (WLI) techniques, such as the widely used scanning WLI (S-WLI) and spectral-domain WLI (SD-WLI). The performance of a white-light interferometric sensing system depends not only on the design of the probes, but also, to a great extent, on the …
-
Sapphire Fiber Optic Sensor for High Temperature Measurement
… sensor by white-light-interferometry (WLI). Temperature resolution better than 1°C was achieved. Chapter 3 discusses a novel approach to demodulate an optical F-P cavity at low-cost. A simple interrogator is demonstrated, which is based on the scanning-white-light-interferometry …
-
Berührungslose kontinuierliche Topografiemessung auf bewegten Körpern
… Oberflächen ist die Weißlichtinterferometrie (WLI) etabliert. Mit ihr sind Topografiemessunsicherheiten in der Größenordnung einzelner Nanometer möglich. Die am weitesten verbreitete Umsetzung des WLI-Prinzips für Topografiemessungen ist die vertikal scannende WLI (VSWLI), die allerdings …
-
Geology and Petrology of the Wilder Lake Intrusion, Duluth Complex, Northeastern Minnesota
Abstract The Wilder Lake Intrusion (WLI) is a well differentiated, northward-dipping, sheet-like mafic layered intrusion that is part of the 1.1 Ga Duluth Complex exposed in northeastern Minnesota. While several reconnaissance studies of the well exposed western quarter of the WLI have shown it to …
-
Vergleichende Rauheitsanalyse von dentalen Implantaten und Methodenvergleich mittels Rasterelektronenmikroskopie und Weißlichtinterferometrie
… generiert die Weißlichtinterferometrie (WLI) die genauesten Sa Werte. Aber auch im Rasterelektronenmikroskop (REM) kann der Sa Wert mittels Shape-from-shading Methode einfach ermittelt werden. Die Arbeit soll nicht nur die Fragen beantworten, welche Unterschiede sich für die Rauheit …
-
Experience of work-life interaction in the mining industry : a phenomenological study
… research has been done on work-life interaction (WLI) in the mining industry in South Africa. Mining is a high-risk profession and the custom of reducing the occurrence of morbidity and inhumanity in these industries must be gainfully considered. Many of the individuals who work in the mining …
-
Processing of Interferometric Data
… algorithms for white-light interferometry (WLI) and line scanning WLI are developed and their performance is compared. For large height differences, multiple wavelength interferometry is significantly faster, though, as in this approach the number of frames required for a surface estimate …
-
QUANTUM AUTHENTICATION IN SPACE SYSTEMS USING THE HONG-OU-MANDEL DIP
… dip phenomenon and white light interferometry (WLI). By leveraging quantum encryption principles, the research aims to develop a quantum authentication scheme capable of providing near-perfect security for optical communication systems. The experimental set up involved using a bi-photon source …
-
Advanced Topographic Characterization of Variously Prepared Niobium Surfaces and Linkage to RF Losses
… therefore introduce white light interferometry (WLI) approach as an alternative. We examined real surfaces and their replicas, using AFM and WLI. We find that the replica/WLI is promising to provide the large majority of desired information, so that use of the time-intensive AFM approach can be …
-
Modeling and Signal Processing of Low-Finesse Fabry-Perot Interferometric Fiber Optic Sensors
… processing based on White-Light-Interferometry (WLI). In the first chapter, the technical background of the low-finesse FPI sensor is briefly reviewed and the problems to be solved are highlighted. A model for low finesse Extrinsic FPI (EFPI) is developed in Chapter 2. The theory is …
-
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
… models was assessed for whole lung irradiation (WLI). The mixed Monte Carlo and measurements model was found to be accurate. The uncertainty in the dose was found to be below 9.4 % of the local dose. A comparison of the out-of-field dose delivered by the 6MV FFF and 10MV FFF beams relative to the …
-
Optinių padėklų paviršiaus šiurkštumo kontrolės ir jo įtakos aukšto atspindžio dangų optiniams nuostoliams tyrimas /
… Microscope (AFM), White Light Interferometer (WLI), and Low Coherence Interferometer (LCI) were combined to construct a Master Power Spectral Density (PSD) function. Furthermore, total optical losses and final reflectivity were evaluated using Cavity Ring-down(CRD)method. Thermal effects and …
-
Low coherence fibre optic Fabry-Perot sensors suitable for multiplexed strain measurement
… on the use of white light interferometer (WLI) techniques to measure the optical path changes produced in the sensors by the application of strain. Since thermal effects also produce phase changes in the fibre Fabry-Perot interferometer (FFPI) which are indistinguishable from strain changes …
-
Computer vision aided diagnosis and guidance in endoscopic urology
… limitées et dans deux modalités d'images (NBI et WLI). Enfin, nous montrons que les modèles proposés peuvent être intégrés dans des robots flexibles pour réaliser une navigation intraluminale autonome.
-
A Study of Optical-Fibre Electronically-Scanned White Light Interferometric Sensor Systems
… principles of white-light interferometry (WLI) techniques are examined, providing a comparison of these techniques with conventional interferometric methods, highlighting the key advantages of the former. The mechanically- and electronically-scanned WLI methods are also compared and …
-
Novel light sources and high-resolution interferometric applications
… on phase-shifting white-light interferometry (PS-WLI) with stroboscopic illumination. An analysis method was developed which made it possible to detect vibration amplitudes below 100 picometers. Further, it was found that for the best performance of PS-WLI an optimal spectral width of the …
-
Measurement and analysis of surface topography over multiple length scales: application to titanium bone implants
… Microscopy (AFM) and White-Light Interferometry (WLI), are compared and contrasted. A custom-designed MATLAB-based program is developed to analyze the images from both tools, and to extract fourteen different statistical topography parameters. The errors associated with measurement and image …
-
Capsule endoscopy system with novel imaging algorithms
… modes – conventional white light imaging (WLI) and emerging narrow band imaging (NBI). The average compression ratio achieved using the proposed lossy compression algorithm is 80.4% for WBI and 79.2% for NBI with high reconstruction quality index for both bands. Two surveys have been …
-
Evaluation of Proposed Natural Corrosion Inhibitors for X-52 Carbon Steel in Ethanol Media
… microscopy (SEM) and White light interferometry (WLI). The results suggest that linalyl formate promotes the highest corrosion inhibition efficiency at 10 mM, followed by citronellyl acetate and linalyl butyrate. At this concentration, 1-pentylallyl acetate and linalyl acetate have not promoted …
-
Avaliação tribológica de um óleo mineral aditivado com nanopartículas superparamagnéticas de óxido de ferro
… Spectroscopy and White Light Interferometry (WLI), using the results obtained for pure oil as references. The SPIONs best results as antifriction additive were obtained with the low loads (30 N and 50 N) and with the rough surface (Ground).
Page 1 of 2