Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 50 for “"WUFI"”.
-
Study of moisture conditions in a multi-story mass timber building through the use of sensors and WUFI hygrothermal modeling
… for hygrothermal properties and integrated into WUFI, a simulation software, for analysis of the building. The software showed limitations for correctly simulating the behavior of CLT in isolated lab experiments and therefore a re-calibration was performed for accurate simulation. Preliminary …
-
Moisture Safety in Wood Frame Buildings - Blind evaluation of the hygrothermal calculation tool WUFI using field measurements and determination of factors affecting the moisture safety
Due to increased awareness of climate change and higher energy costs, well-insulated buildings have become more common. Furthermore, interest in the use of wood in building to produce more carbon dioxide-efficient buildings has increased. However, thicker thermal insulation in building envelopes …
-
Moisture safety in wood frame walls : blind evaluation of the hygrothermal calculation tool WUFI 5.0 using field measurements and determination of factors affecting the moisture safety
Due to increased awareness of climate change and higher energy costs, well‐insulated buildings have become more common. Furthermore, the interests of using wood in building to produce more carbon dioxide‐efficient houses have increased. However, thicker thermal insulation in walls increases the …
-
Varðveiting íslenskra útveggja
… raka- og varma flæðis greiningum í forritinu WUFI® Pro. Greint er frá helstu gerðum steypuskemmda og skoðað fyrir hvaða hrörnunarferlum íslenski útveggurinn er viðkvæmastur. Niðurstöður sýna að hátt rakastig í steypu er mikill orsakavaldur steypuskemmda og íslenski útveggurinn er almennt með …
-
Áhættugreining þaka : veikleikar og mögulegir hönnunargallar
… Rakaaðstæður eru metnar með aðferð Glasers og WUFI.
-
Hygrothermal Analysis of Vacuum Insulation Panels in New and Retrofit Walls for Canada
… The numerical study was performed using WUFI Pro 6.1 and WUFI 2D. The hygrothermal model was validated using the in-situ monitored data from 2016 to 2020 for Ottawa, CA. A methodology to model VIP insulated wall assemblies for building envelope retrofits was presented and performed in …
-
Návrh vytápění administrativní budovy
… model administratívnej budovy v programe WUFI Plus a sú popísané simulácie pri rôznych vstupných okrajových podmienkach.
-
Criterios de diseño biohigrotérmico de envolventes para limitar la aparición del hongo de pudrición serpula lacrymans en viviendas de madera del centro-sur de Chile
… de diseño mediante modelación dinámica con WUFI Pro y su postprocesador WUFI Bio. La investigación combinó tres enfoques: diagnóstico en viviendas afectadas, caracterización biológica y mecánica de aislados nativos en laboratorio, y modelación higrotérmica y biohigrotérmica de soluciones …
-
Thermal performance of closed-cell foam insulation board under different temperature conditions
… simulation software packages, such as WUFI, consider linear temperature dependent R-value profiles, even for polyiso. However, neither the linear temperature dependent thermal resistance nor the constant thermal resistance value of polyiso represents the actual thermal performance of …
-
Combining energy, indoor air quality and moisture models for assessing the whole building performance
… phase, the feasibility of coupling CONTAM with WUFI has been evaluated, and in the third phase, the feasibility of combining EnergyPlus, CONTAM and WUFI has been concluded. To analyze the differences of the simulated results by the combined and single models methods, four scenarios are defined …
-
Analýza transportu vzdušné vlhkosti v obalových konstrukcích budov
… DEKSOFT – Tepelná technika 1D a v softwaru WUFI 2D, popisem jednotlivých modelů a analýzou dosažených výsledků. V závěru praktické části jsou validovány dosažené teoretické poznatky analýzou získaných dat z praktického modelu.
-
Attic Ventilation in Extremely Cold Climate - Field Measurements and Hygrothermal Simulation
… At the same time, hygrothermal modelling using WUFI Plus, a whole-building hygrothermal simulation software, are performed and simulation results are compared with measurements for model validation. Validated models are also performed in other location to further verify their universality. Attic …
-
Investigation on moisture buffering of hygroscopic materials by full-scale experiments and HAM simulations
… of local moisture buffering of interior surface (WUFI) applied on test walls; and 3) analyses of moisture buffering capacity at material level using WUFI simulations. A new index, maximum accumulated moisture buffering value (MAMBV), is developed to quantify the impact of different parameters on …
-
Performance Simulation of Brick Construction under the Impacts of Increased Precipitation as a Consequence of Climate Change
… the interaction between brick and mortar. Also, WUFI is applied to confirm the hypothesis in performance tolerance by simulation for the scenario under medium precipitation and severe precipitation with higher temperature. Calculated moisture content profiles are discussed to provide some …
-
A Method for the Assessment of Moisture Conditions of Painted Wood Siding in Historic Wood Frame Buildings
… and liquid moisture sources is analyzed using WUFI Pro based on the Sd-value and Aw coefficient. Interior and exterior sources of moisture were found to impact the exterior siding. For Ottawa's climate, an exterior paint layer that is permeable (Sd<=0.5m) and with a lower Aw coefficient …
-
Modélisation hygrothermique de l'enveloppe du bâtiment avec le matériau de chanvre
… Les résultats de la simulation avec le logiciel WUFI Pro 6.2 des murs dans le cadre d’une étude pour la ville de Montréal ont révélé que le béton de chanvre présente une excellente qualité de régulation de la chaleur et de l’humidité, donc aucun problème de dégradation causé par l’humidité n’est …
-
Effect of Vapor Diffusion Port on the Hygrothermal Performance of Wood-Frame Walls
… effect of VDPs, hygrothermal simulations using WUFI 2D are carried out in this study. The WUFI 2D model is firstly validated by comparing simulation results to measurements from tests carried out under laboratory conditions by using a wetted wood block installed inside each test wall assembly as …
-
Moisture response of CLT floor assemblies under indoor water leakage: Experimental and simulation-based assessment
… testing and numerical simulations using WUFI 1D and 2D. Six assembly configurations were evaluated, including variations in surface exposure, joint conditions, and end-grain vulnerability. Results revealed that end-grain surfaces are highly susceptible to deep moisture ingress and …
-
Hliněné omítky pro venkovní použití
… pomocí numerických simulací v programu WUFI, založených na experimentálních datech. Výsledky simulací ukazují, že aplikace malého množství (do 2 %) zkoumaných hydrofobizačních přísad nemá výrazný vliv na tepelně-vlhkostní parametry simulované konstrukce a nezvyšuje tak ani riziko hniloby …
-
Mätning och simulering av värmeflöde och u-värde i tegelbyggnader
… känslighetsanalys i dataprogrammet WUFI samt analys av mätdata från den fysiska byggnaden. En nybyggd testvägg i laborationsmiljö med hänsyn till randeffekter mäter ett U-värde mellan 0,6–0,77 W/m²K med hjälp av värmeflödessensorer. Relativa fuktigheten, solstrålning och väggens …