Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"WUFI 2D"”
-
Analýza transportu vzdušné vlhkosti v obalových konstrukcích budov
… DEKSOFT – Tepelná technika 1D a v softwaru WUFI 2D, popisem jednotlivých modelů a analýzou dosažených výsledků. V závěru praktické části jsou validovány dosažené teoretické poznatky analýzou získaných dat z praktického modelu.
-
Effect of Vapor Diffusion Port on the Hygrothermal Performance of Wood-Frame Walls
… effect of VDPs, hygrothermal simulations using WUFI 2D are carried out in this study. The WUFI 2D model is firstly validated by comparing simulation results to measurements from tests carried out under laboratory conditions by using a wetted wood block installed inside each test wall assembly as …
-
Moisture management in VIP retrofitted walls
… VIP using a 2-D hygrothermal simulation tool WUFI-2D. Eight North American locations were considered, based on Moisture Index (MI) which varied between 0.13 and 1.17, and two different indoor hygrothermal loading conditions as prescribed by the ASHRAE 160P and EN 13788, respectively. The …
-
Existing Buildings against Climate Zone Shifts: Analysis of the resilience of existing buildings in changing climate zones
… Hygrothermal simulations were performed using WUFI 2D under baseline (2020) and projected future climate conditions (2040 and 2080) using Future Typical Meteorological Year (FTMY) weather files aligned with a high-emissions SSP5 scenario. Performance metrics included relative humidity, water …
-
Hygrothermal Analysis of Vacuum Insulation Panels in New and Retrofit Walls for Canada
… The numerical study was performed using WUFI Pro 6.1 and WUFI 2D. The hygrothermal model was validated using the in-situ monitored data from 2016 to 2020 for Ottawa, CA. A methodology to model VIP insulated wall assemblies for building envelope retrofits was presented and performed in …
-
Retrofitting an old warehouse using vacuum insulation panels - Hygrothermal analysis and life cycle cost assessment
… façade has been controlled using the software WUFI 2D. It results that the VIPs offer an efficient thermal solution but the implementing VIPs is more expensive that insulating with conventional materials. Owing to this, it seems that re-insulating Kajskjul 113 with VIPs is not the most optimal …
-
Caractérisation et optimisation d'un composite biosource pour l'habitat
Cette étude a pour objet de comparer les propriétés acoustiques, mécaniques et hygrothermiques de différents biocomposites destinée à l’isolation des bâtiments à base de granulats issus de co-produits végétaux et d’un liant à base d’argile. Nous avons d’abord analysé les matières premières afin …