Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 153 for “"Water Cooling"”

  1. Predictive maintenance of industrial water cooling systems

    Working in the practical environment of the LAUDA Ultracool company, this project worked with industrial refrigeration equipment to detect and diagnose failures before they impact the efficiency of the machine. Once the limitations of the literature in an industrial environment had been identified, …

    barcelona Repository record for Predictive maintenance of industrial water cooling systems (opens in a new tab)

  2. Dynamic modelling of the natural convection water cooling principle

    … operating characteristics of the Reactor Cavity Cooling System (RCCS) of the Pebble Bed Modular Reactor (PBMR) demonstration power plant during the active and passive operation conditions. Fortunately, the RCCS experience no circulation anomalies during active operation conditions, due to the …

    nwu-za Repository record for Dynamic modelling of the natural convection water cooling principle (opens in a new tab)

  3. Heat transfer during spray water cooling using steady experiments

    Spray water cooling is widely used in many industrial processes to control heat removal from a hot material surface. In order to control heat transfer rates and obtain desired surface temperature distributions, a deeper understanding of fundamental spray cooling dynamics and more accurate …

    uiuc Repository record for Heat transfer during spray water cooling using steady experiments (opens in a new tab)

  4. Analysis of water cooling process of steel strips on runout table

    This study engages in the thermal analysis of water jet cooling of a hot moving steel strip on a run-out table. General 3D FE programs are developed for the direct and inverse heat transfer analysis. Studies show that gradient-based inverse algorithms suffer from high sensitivity to measurement …

    ubc Repository record for Analysis of water cooling process of steel strips on runout table (opens in a new tab)

  5. Synthetic image generation of factory stack and water cooling tower plumes

    Remote sensing of cooling tower and factory stack plumes may provide unique information on the constituents of the plume. Potential information of the power generated by the plant or the chemical composition of the factory products may be gathered from thermal emission and absorption in the …

    rit Repository record for Synthetic image generation of factory stack and water cooling tower plumes (opens in a new tab)

  6. Dynamic Modeling and Gain Scheduling Control of a Chilled Water Cooling System

    … and Gain Scheduling Control of a Chilled Water Cooling System Jun Liu In this thesis, a dynamic model of a chilled water (ChW) cooling system with a stratified ChW tank was developed. The model-based analysis of the energy consumption and the cost under different control strategies were …

    concordia

  7. Finite element simulation of water cooling process of steel strips on runout table

    … scale for an effective FE simulation of the water cooling processes of steel strips on run-out table (ROT). General 2D FE programs are developed for the direct and inverse heat transfer analyses. Both the Flux Zoning Method (FZM) and Flux Marching Method (FMM) are proposed to specify the heat …

    ubc Repository record for Finite element simulation of water cooling process of steel strips on runout table (opens in a new tab)

  8. Temporal and Ecological Community Dynamics of Water-Cooling Tower Associated <i>Legionella</i> spp.

    Man-made water systems can have complex microbial communities. Legionella spp. are ubiquitous in these environments and, with favorable conditions, can lead to outbreaks of Legionnaires disease. Included in these water systems are free living amoebas (FLA) and potential other eukaryotes that may …

    clemson Repository record for Temporal and Ecological Community Dynamics of Water-Cooling Tower Associated <i>Legionella</i> spp. (opens in a new tab)

  9. Quantification of heat transfer associated with water cooling in dies for low pressure die casting

    … solidification and avoid casting defects. Water-cooled channels embedded in the die play a key role in heat extraction, yet their design is often based on trial and error knowledge due to limited fundamental understanding of boiling behavior under transient cooling conditions. This research …

    ubc Repository record for Quantification of heat transfer associated with water cooling in dies for low pressure die casting (opens in a new tab)

  10. Dynamic modelling and on-off switching control of a chilled water cooling system with storage

    … integrated system here is referred to as chilled water cooling system with storage.

    concordia

  11. Diode laser modules based on laser-machined, multi-layer ceramic substrates with integrated water cooling and micro-optics

    … conductivities allow an efficient passive cooling. However, as the number of emitters per package increases and improvements in the laser technology enable higher output power, the passive cooling will become insufficient. To overcome this problem, a LTCC platform capable of actively …

    heriot-watt Repository record for Diode laser modules based on laser-machined, multi-layer ceramic substrates with integrated water cooling and micro-optics (opens in a new tab)

  12. Comparison of Sensible Water Cooling, Ice building, and Phase Change Material in Thermal Energy Storage Tank Charging: Analytical Models and Experimental Data

    … that using normal HVAC temperatures, sensible water chilled to its maximum value after only about two hours, while PCM would take nearly six hours to achieve “linkage,” or solidified material merging between the helix coils. Ice building, done with -7° coolant, took 4.5 hours to achieve …

    ohiolink Repository record for Comparison of Sensible Water Cooling, Ice building, and Phase Change Material in Thermal Energy Storage Tank Charging: Analytical Models and Experimental Data (opens in a new tab)

  13. Evaluation of low pressure leak flows in metallic vacuum vessels for detection systems using helium dissolved in an external water cooling jacket

    … evaluated herein utilizes helium dissolved in a water jacket surrounding a vacuum vessel for the detection of leaks. The Water jacket and vacuum vessel that are considered in these analyses are part of athermal management and isolation system for a cold neutron moderator in the High FluxIsotope …

    ut-knoxville Repository record for Evaluation of low pressure leak flows in metallic vacuum vessels for detection systems using helium dissolved in an external water cooling jacket (opens in a new tab)

Page 1 of 8