Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"Water chillers"”

  1. SIMULATION OF ABSORPTION CYCLES FOR INTEGRATION INTO REFINING PROCESSES

    … is an immense energy consumer. Absorption chillers can be used to recover liquid natural gas (LNG) plant waste heat to provide cooling, which is especially valuable in the oil and gas industry and would also improve energy efficiency. This thesis details the modeling procedure for single …

    maryland Repository record for SIMULATION OF ABSORPTION CYCLES FOR INTEGRATION INTO REFINING PROCESSES (opens in a new tab)

  2. A new geothermal cooling – heating system for buildings : geothermal cooling – heating for hot – humid climates

    Single stage absorption chillers (water/lithium bromide) can operate using low grade heat, thus single stage absorption chillers can operate using low temperature geothermal resources. An EES computer model was written for a single stage absorption chiller based on overall heat transfer …

    akureyri Repository record for A new geothermal cooling – heating system for buildings : geothermal cooling – heating for hot – humid climates (opens in a new tab)

  3. Resource efficient and cleaner production in selected foundries through environmental performance evaluation

    … performance indicators of specific energy and water use, metal yield and sand regeneration ratio. The gap between the benchmarks and actual performances revealed the improvement potential. The results indicated that specific energy consumption can be improved by 27% and 54% for iron and steel …

    metu Repository record for Resource efficient and cleaner production in selected foundries through environmental performance evaluation (opens in a new tab)

  4. A MODELLING STUDY OF VARIABLE AIR-VOLUME FAN COIL UNIT (VAV-FCU)

    … a building. Energy consuming equipment such as chillers, fans, pumps and lights are sized to meet demands dictated by the building function. In particular, air-conditioning equipment must be . capable of meeting the building peak cooling load. Air-conditioning system is the largest single …

    nus Repository record for A MODELLING STUDY OF VARIABLE AIR-VOLUME FAN COIL UNIT (VAV-FCU) (opens in a new tab)

  5. Evaluation of Existing Subsurface Cooling Systems Worldwide and Development of Efficient Cooling Methods and Systems Based on Renewable Energy Sources

    … of potential cooling energy comes from cold-water applications. The cold water can come from ice (stowed or transported), in situ reservoirs or refrigerated water chillers in either low or high-pressure systems. The main issue with ice is the service temperature is limited to freezing point …

    unr Repository record for Evaluation of Existing Subsurface Cooling Systems Worldwide and Development of Efficient Cooling Methods and Systems Based on Renewable Energy Sources (opens in a new tab)

  6. Étude d'une compression refroidie par injection d'huile dans un compresseur scroll : application au remplacement du R-410A dans les groupes refroidisseurs d'eau

    Le problème du réchauffement climatique actuel conduit au renforcement des règlementations environnementales. Ainsi, le domaine du génie climatique est affecté par ces évolutions réglementaires, ce qui impose le passage à une nouvelle génération de réfrigérants à plus bas impact environnemental. …

    star-france Repository record for Étude d'une compression refroidie par injection d'huile dans un compresseur scroll : application au remplacement du R-410A dans les groupes refroidisseurs d'eau (opens in a new tab)