Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"Water-Purification-Arsenic Removal"”
-
Removal of arsenic from water using chitosan and nanochitosan
… of adsorbates and adsorbents, is widely used in water and wastewater treatment in most natural systems as well as in industrial applications. This research project aims at studying the sorption capacity, uptake kinetics and mechanism of arsenic removal, including arsenate and arsenite onto …
-
Evaluation and optimization of selected methods of arsenic removal from industrial effluent
This research was directed at reducing arsenic levels in the effluents generated at the Canelands facility that manufactures monosodium methyl arsenate. Two effluent streams containing arsenic have to be considered, a raw water stream that is treated on site and a brine stream that is disposed of …
-
Arsenic adsorption onto iron-chitosan composite from drinking water
To develop an inexpensive adsorbent, suitable for arsenic removal from drinking water, iron-chitosan based sorbents were selected. Chitosan is a biopolymer derived from chitin, a polysaccharide and is available commercially in the form of flakes. To be used in an adsorption system, chitosan should …
-
Role of natural organic matter on the adsorption of As(V) and As(III) oxyanions to metal oxides, The
Includes bibliographical references (pages 71-76).
-
Removal of chromium(VI) and arsenic(V) by zero-valent iron from humic acid-rich groundwater with various geochemical constituents
… and organic pollutants from contaminated groundwater as an in situ remediation technology. The mechanisms responsible for contaminants removal are also well understood. However, uncertainties remain concerning the effectiveness of Fe<sup>0</sup> PRBs in complicated subsurface environments. Among …
-
Removal kinetics and mechanisms of chromium(VI) and arsenic(V) in groundwater by permeable reactive barriers with environmental life cycle assessment
… (PRBs) for removing Cr(VI) and As(V) from groundwater with various geochemical constituents such as hardness, alkalinity and natural organic matter (NOM) was investigated. In addition, the associated environmental impacts of using these materials as the reactive media in PRBs with the effects of …
-
Development and evaluation of innovative iron-containing porous carbon adsorbents for arsenic removal
… OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] Arsenic is of serious concern because of its marked negative impacts to human health. Of the various sources of arsenic in the environment, drinking water poses the greatest threat to human health. A variety of treatment processes have been examined …
-
Removal of Arsenic Using Iron Coated Limestone
Arsenic contamination in drinking water is a severe problem worldwide. The best way to prevent hazardous diseases from chronic arsenic exposure is to remove the exposure. Efforts to remediate arsenic in drinking water have taken two tracks. One is to provide surface or shallow well water sources as …
-
Arsenic rejection by membrane processes : model development and application
… This study investigated the rejection of arsenic by several nanofiltration and inorganic clay membranes. Laboratory-scale experiments were conducted using both dead-end and cross flow systems. Firstly, the nanofiltration membranes, NF270 and TFC-SR-2, were selected for arsenic rejection in …
-
Selective fluoride removal by aluminum precipitation & membrane filtration
… constituent of most natural surface and ground waters. At low concentrations it has the beneficial effect of improving dental health, but at high concentrations it causes skeletal and other problems. The drinking water standard for fluoride is 4.0 mg/L, but even at this level approximately 10% …
-
Removal of arsenic from Newfoundland water using impregnated peat
Arsenic exists naturally and it is the 20th most abundant element in the earth's crust. The high Arsenic concentration in some of Newfoundland water sources could be due to the oxidation of Arsenic bearing minerals by the heavy precipitations and rain fall all over the year. Arsenic is carcinogenic …
-
Arsenic removal by sand filtration for potable water in rural Newfoundland and Labrador
The high concentration of arsenic in groundwater sources of Newfoundland has been reported by governmental departments and individual researchers. Arsenic uptake by human beings can cause the cancer of lungs, kidneys and skin. The National Health and Medical Research Council (2003), NHMRC, of …
-
Investigation of sustainable waste-derived adsorbents for arsenic and copper in water treatment
Arsenic contamination in drinking water is a global issue, affecting millions and posing serious health risks such as cancer and neurological disorders. This is particularly critical in communities relying on groundwater. This research explores using mussel shells and agricultural waste, including …
-
Synthesis and potential application of Fe3+/Mn2+ bimetal and hexadecyltrimethylammonium bromide (HDTMA-Br) modified clayey soils for arsenic removal in groundwater
The presence of arsenic in groundwater has drawn worldwide attention from researchers and public health officials due to its effects on human health such as, cancer, skin thickening, neurological disorders, muscular weakness, loss of appetite and nausea. World Health Organisation (WHO) has set the …