  1. Comparative study on cleaning efficacy of two single file systems in oval canals: waveone and self-adjusting file

    … από επεξεργασία με δύο συστήματα ενός εργαλείου: WaveOne και Self-Adjusting File.Επιλέχθηκαν 24 μονόρριζοι μόνιμοι προγόμφιοι με ένα ωοειδή ριζικό σωλήνα, ένα ακρορριζικό τρήμα και πλήρως διαπλασμένο ακρορρίζιο. Τα δόντια διαχωριστήκαν σε δύο ομάδες με ομοιόμορφη κατανομή: Ομάδα Α, όπου έγινε …

    athens Repository record for Comparative study on cleaning efficacy of two single file systems in oval canals: waveone and self-adjusting file (opens in a new tab)

  2. Resistência em fadiga cíclica de instrumentos reciprocantes fabricados com ligas de niquel-titânio submetidas a diferentes tratamentos térmicos

    … types of single file reciprocating systems: WaveOne Gold Primary (25 / 0.07), WA1 file (25 / 0.07) and X1 Blue (25 / 0.06), made of nickel-titanium alloys with different surface thermal treatments, and compare Reciproc All and WaveOne All programs, regarding the fatigue life of the three …

    brazil-ufrn Repository record for Resistência em fadiga cíclica de instrumentos reciprocantes fabricados com ligas de niquel-titânio submetidas a diferentes tratamentos térmicos (opens in a new tab)

  3. Efficiency and Safety of a Continuous Rotation Instrumentation System and a Reciprocating Motion Instrumentation System: A Randomized Clinical Trial

    … that single-file reciprocating systems, such as WaveOne, are capable of more rapid root canal instrumentation compared to systems that utilize multi-file continuous rotation. The purpose of this study was to evaluate the efficiency and safety of WaveOne and ProTaper Next instrumentation systems …

    uconn-diss Repository record for Efficiency and Safety of a Continuous Rotation Instrumentation System and a Reciprocating Motion Instrumentation System: A Randomized Clinical Trial (opens in a new tab)

  4. Micro–Computed Tomographic Evaluation of Shaping Ability by Novice Dental Students with 3 Reciprocating File Systems; WaveOne Gold, EdgeOne Fire and ESR

    … dental students and endodontic residents, while WaveOne Gold reciprocating file system is the second most taught among dental students. A previous study by Endodontic department in Temple University, Kornberg School of Dentistry reported that novice dental students preferred the reciprocating …

    temple Repository record for Micro–Computed Tomographic Evaluation of Shaping Ability by Novice Dental Students with 3 Reciprocating File Systems; WaveOne Gold, EdgeOne Fire and ESR (opens in a new tab)

  5. Avaliação da variabilidade intra-fabricante e da compatibilidade do diâmetro de cones de guta-percha com o diâmetro do instrumento WaveOne Gold Medium

    … marcas de cones principais de guta-percha (WaveOne Gold Medium, EndoTanariPlus #35.06, W-File TDKaFiles Medium) e de cones acessórios (Odous de Deus M e ML) com instrumento WaveOne Gold medium (WOG). Uma régua calibradora padronizou a ponta dos cones acessórios M e ML. Um paquímetro digital …

    brazil-ufrgs Repository record for Avaliação da variabilidade intra-fabricante e da compatibilidade do diâmetro de cones de guta-percha com o diâmetro do instrumento WaveOne Gold Medium (opens in a new tab)

  6. Comparative Evaluation of Three Endodontic Rotary File Systems in S-shaped Root Canals: An In-depth Analysis

    … file systems—XP‐3D Shaper⁺, EdgeFile X7 and WaveOne Gold in S‐shaped simulated canals in resin blocks. It aimed to quantify canals volumetric changes post‐instrumentation to guide clinical selection of a system that preserves tooth structure while efficiently shaping root canals. Methods: …

    vcu Repository record for Comparative Evaluation of Three Endodontic Rotary File Systems in S-shaped Root Canals: An In-depth Analysis (opens in a new tab)

  7. Retrospektive vergleichende Analyse des Erfolgs von Wurzelkanalbehandlungen mit Mehrfeilensystemen und Einfeilensystemen

    … mit ProTaper® therapiert worden, 140 Zähne mit WaveOne™. Bewertungen wurden anhand prä- und postendodontischer Röntgenbilder durchgeführt. Der Erfolg wurde mithilfe des periapikalen Index beurteilt. Für die Einschätzung der Qualität wurden die Parameter Wurzelfülllänge, Beibehaltung des …

    fu-berlin Repository record for Retrospektive vergleichende Analyse des Erfolgs von Wurzelkanalbehandlungen mit Mehrfeilensystemen und Einfeilensystemen (opens in a new tab)

  8. Comparative Analysis of WaveOne and LightSpeed LSX for the Residual Dentin Thickness of the Bifurcated Maxillary First Premolar Buccal Root Utilizing Limited Field Cone Beam Computed Tomography

    … of furcation groove after instrumentation with WaveOne and LightSpeed LSX files utilizing limited field cone beam computerized tomography. All data was analyzed using repeated-measured mixed-model ANOVA and differences were described using Tukey’s multiple comparison procedure. The thickness of …

    vcu Repository record for Comparative Analysis of WaveOne and LightSpeed LSX for the Residual Dentin Thickness of the Bifurcated Maxillary First Premolar Buccal Root Utilizing Limited Field Cone Beam Computed Tomography (opens in a new tab)

  9. Comparação do desempenho dos sistemas de níquel-titânio de rotação contínua, alternada e sua associação no preparo de canais radiculares curvos: estudo in vitro

    … rotação contínua ProTaper®, de rotação alternada WaveOne® e uma sugestão de técnica híbrida de preparo. Foram selecionadas raízes mesiais de primeiros molares inferiores humanos permanentes extraídos. Após a definição dos ângulos de curvatura e raio, os canais (n=60) foram divididos em três grupos …

    brazil-ufrgs Repository record for Comparação do desempenho dos sistemas de níquel-titânio de rotação contínua, alternada e sua associação no preparo de canais radiculares curvos: estudo in vitro (opens in a new tab)

  10. In vitro-Untersuchung der Aufbereitungsqualität reziproker und rotierender Wurzelkanalaufbereitungsinstrumente im Mikro-CT

    … Wurzelkanalaufbereitungssysteme Reciproc und WaveOne Gold, des adaptierend rotierend-reziproken Systems Twisted File Adaptive und des rotierenden Systems HyFlex EDM. Anhand von Mikro-CT-Aufnahmen extrahierter Zähne vor und nach Wurzelkanalaufbereitung wurden die Volumenänderung, der Anteil der …

    lmu-germany Repository record for In vitro-Untersuchung der Aufbereitungsqualität reziproker und rotierender Wurzelkanalaufbereitungsinstrumente im Mikro-CT (opens in a new tab)

  11. Eficácia de diferentes técnicas de retratamento endodôntico de canais radiculares curvos

    … apical de debris durante a desobturação com WaveOne Gold, ProTaper retratamento, D-RaCe ou limas manuais; descrever as falhas e/ou fraturas ocorridas nos instrumentos de NiTi; e comparar o WaveOne Gold com os sistemas ProTaper e RaCe em relação à quantidade de material obturador remanescente, …

    brazil-ufrgs Repository record for Eficácia de diferentes técnicas de retratamento endodôntico de canais radiculares curvos (opens in a new tab)

  12. Canal Transportation after Instrumentation Utilizing Different Endodontic Access Design; A Comparative Study with Micro-CT.

    … on varying the access cavity designs, using WaveOne Gold®(WOG) and ProTaper NEXT®(PTN) files. Materials and Methods All teeth used were 3D printed maxillary first molar teeth purchased from Dental Education Laboratories. One unaltered tooth was scanned with a SkyScan 1272 microCT to be used …

    wvu Repository record for Canal Transportation after Instrumentation Utilizing Different Endodontic Access Design; A Comparative Study with Micro-CT. (opens in a new tab)

  13. Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files

    … whether the cyclic fatigue resistance (CFR) of WaveOne (WO), WaveOne Gold (WOG), Reciproc (RE), and Reciproc Blue (REB) are affected by the location of the canal’s curvature. The phase transformation behaviors of the reciprocating file systems were also investigated. Methods: The reciprocating …

    ubc Repository record for Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files (opens in a new tab) Download PDF for Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files (opens in a new tab)

  14. Influence of Kinematics of Nickel-Titanium Instruments on Root Canal Preparations of Dental Students –A Micro CT Evaluation

    … Currently, two common NiTi rotary instruments, WaveOne Gold and ProTaper Gold, function by two different forms of kinematics: a reciprocating and rotating movement respectively. Currently, preclinical curricula in dental schools do not have a standardized rotary file in which dental students are …

    temple Repository record for Influence of Kinematics of Nickel-Titanium Instruments on Root Canal Preparations of Dental Students –A Micro CT Evaluation (opens in a new tab)

  15. THE INCIDENCE OF ROOT DENTINAL MICRO-CRACKS CAUSED BY RECIPROCATING AND CONTINUOUS ROTARY INSTRUMENTATION

    … canal instrumentation using reciprocating files (WaveOne Gold® and Twisted Adaptive®) and continuous rotation files (Edge Evolve® and EndoSequence®) in an ex-vivo benchtop study. This project used a novel methodology of finding dentinal defects using the “K-cube”, which allows evaluators to …

    vcu Repository record for THE INCIDENCE OF ROOT DENTINAL MICRO-CRACKS CAUSED BY RECIPROCATING AND CONTINUOUS ROTARY INSTRUMENTATION (opens in a new tab)

  16. Avaliação da qualidade do preenchimento de canais radiculares achatados e da compatibilidade do diâmetro de cones de guta-percha e de instrumentos reciprocantes com o diâmetro dos canais

    … por meio da µCT, preparados com instrumento WaveOne Gold Medium (WOGM) e obturados pela técnica do cone único usando AH Plus e BioC Sealer, bem como a compatibilidade do diâmetro do instrumento e de cones de guta-percha com o diâmetro do canal. A amostra foi constituída por instrumentos WOGM …

    brazil-ufrgs Repository record for Avaliação da qualidade do preenchimento de canais radiculares achatados e da compatibilidade do diâmetro de cones de guta-percha e de instrumentos reciprocantes com o diâmetro dos canais (opens in a new tab)

  17. Evaluation of Obturation Extrusion of Guttacore with Varying Insertion Rates

    … simulating plastic blocks were prepared with Waveone Gold nickel titanium rotary files to a size “primary” file. The prepared blocks were divided into three groups: group 1 was obturated using GuttaCore size primary obturator (analogous to the reciprocating file size) at a rate of 1 seconds; …

    uconn-diss Repository record for Evaluation of Obturation Extrusion of Guttacore with Varying Insertion Rates (opens in a new tab)

  18. Avaliação das propriedades físico-químicas de instrumentos reciprocantes de níquel-titânio tratados termicamente

    … instruments with controlled memory. The WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland), WA1 File (WA1; TDKaFile, Mexico City, Mexico) and X1 File (X1; MK Life, Porto Alegre, RS, Brazil) systems were subjected to the torsional fatigue test, according to the ISO 3630-1 …

    brazil-ufrn Repository record for Avaliação das propriedades físico-químicas de instrumentos reciprocantes de níquel-titânio tratados termicamente (opens in a new tab)

  19. Efeito do resfriamento com gás refrigerante na fadiga cíclica de dois instrumentos de níquel-titânio tratados termicamente

    … a resistência à fadiga cíclica dos instrumentos WaveOne Gold (WOG) e X1 Blue File (X1B) testados na temperatura corporal e submetidos ou não ao resfriamento. Metodologia: Para avaliação 20 instrumentos de cada sistema foram selecionados (n=40) e divididos em dois grupos: TC, temperatura corporal …

    brazil-ufrgs Repository record for Efeito do resfriamento com gás refrigerante na fadiga cíclica de dois instrumentos de níquel-titânio tratados termicamente (opens in a new tab)

  20. Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos

    … #25 com os sistemas Twisted File Adaptive (TFA), WaveOne Gold (WOG) e técnica manual (TM), registrar o tempo de preparo; e comparar WOG com TFA em relação ao transporte do canal radicular (TCR) e centralização (CR) com diâmetros apicais #25 e #35. Metodologia: Quarenta e cinco canais …

    brazil-ufrgs Repository record for Comparação do transporte, centralização e extrusão apical de detritos após o uso de sistemas de NiTi em canais radiculares curvos (opens in a new tab)