Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"Welded Wire Reinforcement"”.
-
Tensile Strain Validation of Welded Wire Reinforcement
… historical concerns regarding the ductility of welded wire reinforcement (WWR). Recent changes in ACI 318-19 now require all grades of A615 and Grade 100 A706 nonprestressed steel reinforcement to have a ratio of tensile strength to yield strength greater than 1.10 and 1.17 respectively. …
-
Enhancing Ductility of One-Way Concrete Slabs Reinforced With Welded Wire Reinforcement
… an issue called strain localization in welded wire reinforced (WWR) members. This phenomenon reportedly concentrates strains at welded cross wire locations and severely limit ductility. Those that identified the phenomenon used it to imply that WWR is unsafe because it does not warn of …
-
Evaluating the Mechanical Properties and Fracture Behavior of Welded-Wire Reinforcement Using Tension and Charpy Tests and Sub-Size Charpy Corrections
Welded-wire reinforcement (WWR) is widely used as the main reinforcement in bridge decks and vertical shear reinforcement in concrete bridge girders. Past studies on concrete members reinforced with WWR have indicated that the reduced ductility of the cold-drawn wires leads to lower member …
-
Experimental Investigation of Precast Bridge Deck Joints with U-bar and Headed Bar Joint Details
… practice, would consist of staggered protruding reinforcement that would allow for the anchorage of the precast deck component into the joint. Six specimens containing the joint details were constructed and tested. Three specimens were tested in flexure to simulate the forces that would be …
-
Reducing top mat reinforcement in bridge decks
… serviceability implications of reducing the deck reinforcement across the interior spans of CIP-PCP decks. The goal of this research is to understand how the PCPs influence cracking and crack control in the CIP slab and to make recommendations to optimize the top mat reinforcement accordingly. …
-
Lateral Resistance of H-Piles and Square Piles Behind an MSE Wall with Ribbed Strip and Welded Wire Reinforcements
… The H-piles were tested with ribbed strip soil reinforcement at a wall height of 15 feet, and the square piles were tested with welded wire reinforcement at a wall height of 20 feet. The H-piles were spaced from the back face of the MSE wall at pile diameters 4.5, 3.2, 2.5, and 2.2. The square …
-
Behavior of Reinforced Lightweight Cellular Concrete Backfill for Mechanically Stabilized Earth Walls with Welded Wire Reinforcements
… is poorly understood. The pullout resistance of welded wire reinforcement within LCC is poorly understood as well. This research attempts to add knowledge of LCC behind MSE walls by (1) performing pullout tests on welded wire reinforcements, (2) defining the apparent friction coefficient versus …
-
Design recommendations for CIP-PCP bridge decks
… be further optimized if it can be shown that the reinforcement in the CIP deck can be reduced. Another issue involves cracking of PCP during fabrication and transportation to the site. The goal of this dissertation is to recommend changes to the CIP-PCP bridge decks that will lead to more …
-
Experimental Investigation of Reinforced Concrete Beams with Lapped Reinforcement
… in this project. One type was a headed bar reinforcement which was tested in various spacing and lap lengths. The second type of joint was welded wire reinforcement with varying wire spacing. In order to accelerate bridge construction, it is desirable to narrow the width of the jointed zone. …
-
Shear Capacity of Hollow-Core Slabs with Concrete Filled Cores
… is not conducive to using transverse shear reinforcement, so concrete failure generally governs the shear capacity. Adding slab cross-sectional area is the intuitive way to increase the available shear capacity, but this increases the unit weight, may require a deeper section, and can raise …
-
Reinforced Concrete Shear Walls with Welded Wire Grids as Boundary Element Transverse Reinforcement
… of the web section. Conventional transverse reinforcement placed in shear wall boundary elements consists of hoops, overlapping hoops and crossties, based on the geometry and number of longitudinal bars used. The confinement steel requirement of current building codes (ACI 318 or CSA A23.3) …
-
Development of high performance precast/prestressed bridge girders
… for the Nebraska Department of Roads and for the Wire Reinforcement Institute. Specifically, the following issues were researched: (1) Use of 0.7 in. diameter Grade 270 ksi strands for pretensioning of precast concrete girders at a strand spacing of 2 inches by 2 inches. This arrangement gives …