Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"Wet-bulb Temperature"”.

  1. Short Warm-Side Wet-Bulb Temperature Distribution Tails Lead to Accelerated Increases in Extreme Threshold Exceedances Under Global Warming

    … examines the role of historical (1985-2014) wet-bulb temperature distribution tail shape on the probability of wet-bulb temperature extreme threshold exceedances under 2°Celsius global warming. Analysis of global climate models and reanalysis reveals that non-Gaussian wet-bulb temperature …

    portland-state Repository record for Short Warm-Side Wet-Bulb Temperature Distribution Tails Lead to Accelerated Increases in Extreme Threshold Exceedances Under Global Warming (opens in a new tab)

  2. Effects of wick contamination and thermal component variation on thermal indices

    … were studied: 1. Effect of wick contamination on wet bulb thermometer and Botsball. 2. Effect of wick wetness on Botsball temperature. 3. Effect of thermometer shielding against radiant heat on natural wet bulb temperature. 4. Effect of air velocity and radiant heat on the relationship between …

    ttu Repository record for Effects of wick contamination and thermal component variation on thermal indices (opens in a new tab)

  3. General equation for predicting cooling tower approach temperatures at lower wetbulbs

    Cooling tower approach temperature is the difference in leaving water temperature and entering air wet-bulb temperature. Cooling tower manufacturers describe the design capacity with water volumetric flow, entering water temperature, leaving water temperature, and entering air wet-bulb temperature. …

    alabama Repository record for General equation for predicting cooling tower approach temperatures at lower wetbulbs (opens in a new tab)

  4. Essays in applied microeconomics

    … estimates of the relationship between temperature and maternal mortality in the U.S. Exploiting the year-to-year variation in temperature within states, I use a semiparametic estimation strategy to capture non-linear effects in mortality risks at extreme temperatures. Whereas most of …

    texas Repository record for Essays in applied microeconomics (opens in a new tab)

  5. Psychrometric studies

    The local and macroscopic wet-bulb temperature depressions have been measured for naphthalene, p-dichlorobenzene and d-camphor particles sublimating into an air or helium gas stream. The organic chemicals were moulded into cylindrical, spherical and flat plate 'wet-bulbs'. A simple model based on …

    ubc Repository record for Psychrometric studies (opens in a new tab) Download PDF for Psychrometric studies (opens in a new tab)

  6. SPRINKLER WATER DROPLET EVAPORATION SIMULATED ABOVE A PLANT CANOPY

    … sizes smaller than 1.0 mm reached equilibrium temperature within 2.0 seconds after leaving the nozzle, for an initial water temperature of 15 degrees C, and dry and wet bulb temperatures of 38.0 and 25.8 degrees C, respectively. However, the average temperature (based on volume) for all …

    nebraska Repository record for SPRINKLER WATER DROPLET EVAPORATION SIMULATED ABOVE A PLANT CANOPY (opens in a new tab)

  7. Vertical Mesoscale Water Vapor Flux in an Irrigated Valley

    To obtain the profiles of dry bulb and wet bulb temperature, specific humidity, q, and air density, ρ, to a height of 200 meters above the ground, a precise lightweight thermocouple psychrometer was designed. To lift the thermocouple psychrometer and the attached wires in obtaining the ρq profiles, …

    utahstate Repository record for Vertical Mesoscale Water Vapor Flux in an Irrigated Valley (opens in a new tab)

  8. Improving Health and Safety at Surface and Underground Mines by Implementing Emerging Technologies Coupled With Geotechnical and Climatic Modeling

    … cooling system, a comparison and analysis of the wet-bulb temperature and the dry-bulb temperatures of the ventilating air at the bottom of an intake shaft using two modeling software packages, VentsimTM and ClimsimTM is completed. The comparison shows the consequences and importance of taking …

    unr Repository record for Improving Health and Safety at Surface and Underground Mines by Implementing Emerging Technologies Coupled With Geotechnical and Climatic Modeling (opens in a new tab)

  9. An experimental evaluation of the effect of evaporative cooling of condenser air on the performance of an air conditioning system

    … air conditioning system was determined. The dry bulb temperature of the entering air for an air cod-ed condenser was brought down to near saturated wet bulb temperature by spraying water into the incoming air and the effect on the cooling capacity of the evaporator was observed. Experimental …

    njit Repository record for An experimental evaluation of the effect of evaporative cooling of condenser air on the performance of an air conditioning system (opens in a new tab)

  10. Evaporation maps for ternary non-ideal liquid mixtures

    … gas-phase limited evaporation from a liquid or wetted-solid surface, over which a gas flows at known conditions. Evaporation may occur into a pure inert gas, or into one pre-loaded with a known fraction of one of the ternary components. To explore multicomponent masstransfer effects, a model is …

    cork Repository record for Evaporation maps for ternary non-ideal liquid mixtures (opens in a new tab)

  11. Milk spray dryer digital model development

    … predict and control the air outlet conditions (temperature and humidity) to avoid production loss/downgrade due to excessive stickiness and thermal damage to the powder. It is also important to know the plant powder particle size distribution prior to production as it affects the quality of milk …

    auckland-ms Repository record for Milk spray dryer digital model development (opens in a new tab)

  12. Investigation of the Maisotsenko Cycle Based Air Conditioning Systems

    … coolers. Low cooling capacity (theoretically wet-bulb temperature at 100% relative humidity), adding moisture to the product air and probable health issues due to the contaminated water droplets are the main shortcomings of direct evaporative air coolers. Although conventional indirect …

    adelaide Repository record for Investigation of the Maisotsenko Cycle Based Air Conditioning Systems (opens in a new tab)

  13. Quantifying the impact of water mismanagement on latent heat in deep-level mines

    South African mines are increasing in depth and temperature. This temperature increase has a negative effect on an employee's ability to perform their daily tasks underground which directly affects the mines' production. Water mismanagement leads to increased water on the footwall. This increase in …

    nwu-za Repository record for Quantifying the impact of water mismanagement on latent heat in deep-level mines (opens in a new tab)

  14. Development of a system that can quantify the level of heat strain experienced by underground mine workers in real-time

    … time is most sensitive to changes in the dry-bulb temperature. The dry-bulb temperature, wet-bulb temperature, and clothing resistivity are exponentially connected to changes in the continuous work time. The continuous safe work time of a worker is least affected by changes in airflow velocity …

    unr Repository record for Development of a system that can quantify the level of heat strain experienced by underground mine workers in real-time (opens in a new tab)

  15. Modelling the microclimate in a conical bottomed circular grain silo

    … form are presented for the pressure, velocity, temperature, moisture content, absolute humidity, wet bulb temperature, dry matter loss, seed viability and pesticide decay. Significantly, a novel configuration of an annular aeration duct and a traditional linear aeration duct in farm silos have …

    vu-aus Download PDF for Modelling the microclimate in a conical bottomed circular grain silo (opens in a new tab)

  16. Investigation of geothermal power plant performance using sequestered carbon dioxide as a heat transfer or working fluid.

    … production in areas with low geothermal resource temperatures. Using sequestered CO2 as the working fluid or heat transfer fluid, power production of a Direct Single-Loop System and Binary Organic Rankine Cycle (ORC) System were simulated using Engineering Equation Solver (EES) and the ASHRAE …

    umn Repository record for Investigation of geothermal power plant performance using sequestered carbon dioxide as a heat transfer or working fluid. (opens in a new tab)

  17. An Independent Evaluation of Frozen Precipitation from the WRF model and PRISM in the Olympic Mountains for WY 2015 and 2016

    … used linear-partitioning scheme based on wet bulb temperature (WRFLP) that its estimation of frozen precipitation was biased low on average. However, we found that when SUMMA was allowed to partition WRF total precipitation based on WRF’s microphysical scheme (WRFMPP), simulations of snow …

    washington Repository record for An Independent Evaluation of Frozen Precipitation from the WRF model and PRISM in the Olympic Mountains for WY 2015 and 2016 (opens in a new tab)

  18. The impact of spatial patterns of urban green infrastructure on urban microclimate and air quality

    … impact of UGI’s spatial pattern on land surface temperature and its corresponding distributional inequity. My results show that aggregated tree clusters offer greater cooling benefits than fragments or dispersed green spaces during the day, especially at a larger spatial scale. Mapping mismatches …

    concordia Download PDF for The impact of spatial patterns of urban green infrastructure on urban microclimate and air quality (opens in a new tab)

  19. Evaluation and Use of Stream Temperature Prediction Models for Instream Flow and Fish Habitat Management

    … and RQUAL (Tennessee Valley Authority) stream temperature prediction models were evaluated. All models had high predictive ability with the majority of predictions, >80% for Back Creek (Roanoke County, VA) and >90% for the Smith River tailwater (SRT) (Patrick County, VA), within 3°C of the …

    vt Repository record for Evaluation and Use of Stream Temperature Prediction Models for Instream Flow and Fish Habitat Management (opens in a new tab)

Page 1 of 3