Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Wide Area Measurement System (WAMS)"”.

  1. Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks

    … reduce the outage time and improve the system reliability [1]. With the development of Wide Area Measurement System (WAMS) and Phasor Measurement Unit (PMU), various fault location algorithms have been proposed. The purpose of this work is to determine, modify and test the most …

    vt Repository record for Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks (opens in a new tab)

  2. Multi-Objective Optimal Phasor Measurement Units Placement in Power Systems

    … and control techniques based on the concept of Wide Area Measurement System (WAMS). Phasor Measurement Units (PMUs) are key elements in WAMS based operations of power systems. Most existing algorithms consider the problem of optimal PMU placement where the main objective is to ensure …

    ndsu Repository record for Multi-Objective Optimal Phasor Measurement Units Placement in Power Systems (opens in a new tab)

  3. Wide-area measurement and applications in power system dynamic modeling and control

    … becoming the foundational element of power grid wide-area measurement system (WAMS) since first developed in 1980s. By utilizing global positioning system (GPS) time synchronization technique, synchrophasors offer highly accurate time-synchronized phasor measurements that can provide system …

    utk-theses Repository record for Wide-area measurement and applications in power system dynamic modeling and control (opens in a new tab)

  4. Wide-Area Measurement-Based Applications for Power System Monitoring and Dynamic Modeling

    … complex behavior exhibited by large-scale power systems with more uncertain renewables introduced to the grid, wide-area measurement system (WAMS) has been utilized to complement the traditional supervisory control and data acquisition (SCADA) system to improve operators’ situational awareness. …

    utk-theses Repository record for Wide-Area Measurement-Based Applications for Power System Monitoring and Dynamic Modeling (opens in a new tab)

  5. Propagation of Electromechanical Disturbances across Large Interconnected Power Systems and Extraction of Associated Modal Content from Measurement Data

    Changes in power system operating conditions cause dynamic changes in angle and frequency. These disturbances propagate throughout the system area with finite speed. This propagation takes the form of a traveling wave whose arrival time at a particular point in the system can be observed using a …

    vt Repository record for Propagation of Electromechanical Disturbances across Large Interconnected Power Systems and Extraction of Associated Modal Content from Measurement Data (opens in a new tab)

  6. A New Relaying Method for Third Zone Distance Relay Blocking During Power Swings

    … the increasing complexity of modern bulk power systems, the power swing identification, blocking, and protection have become more challenging than they used to be. Among various transmission line protection methods, distance relays are the most commonly used type. One of the advantages of using …

    sask Repository record for A New Relaying Method for Third Zone Distance Relay Blocking During Power Swings (opens in a new tab)

  7. WAMS-based Intelligent Load Shedding Scheme for Preventing Cascading Blackouts

    … If the mismatch is not rectified quickly, the system may disintegrate into multiple islands. Though the Automatic Generation Controls (AGC) perform well in correcting frequency deviation over a period of minutes, they are ineffective during a rolling blackout. While traditional Under Frequency …

    vt Repository record for WAMS-based Intelligent Load Shedding Scheme for Preventing Cascading Blackouts (opens in a new tab)

  8. A Local Measurement Based Protection Methodology for Initiating Controlled Islanding in Power Systems

    Despite layers of protection at work, power systems still have experienced major blackouts in the past due to cascading outages. Hence, preventing the cascading outage holds the key to the prevention of such blackouts in the future. To address this problem, researchers have proposed controlled …

    sask Repository record for A Local Measurement Based Protection Methodology for Initiating Controlled Islanding in Power Systems (opens in a new tab)

  9. Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors

    … diesel, gas, or hydro generators, energy storage systems, and inverter-based sources such as PV and wind. Although there are several advantages to incorporating DERs into the system, some problems still arise, such as unintentional islanding and protection issues. Islanding detection is one of the …

    sask Repository record for Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors (opens in a new tab)