Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"Wigner-Ville Distribution"”.

  1. Machinery monitoring and diagnostics using pseudo Wigner-Ville distribution and backpropagation neural network

    … successful on unique and noisy data. The pseudo Wigner-ville distribution provides an excellent characterization of a stati

    nps Repository record for Machinery monitoring and diagnostics using pseudo Wigner-Ville distribution and backpropagation neural network (opens in a new tab)

  2. A method for machinery condition monitoring of transient phenomena using the Pseudo Wigner-Ville Distribution

    The Pseudo Wigner Ville Distribution is a time frequency representation of an input time signal and is ideally suited for portraying non-stationary signals. A working computer program is presented and the effect of preprocessing and postprocessing data manipulations is shown. The program has been …

    nps Repository record for A method for machinery condition monitoring of transient phenomena using the Pseudo Wigner-Ville Distribution (opens in a new tab)

  3. An energy analysis of the pseudo Wigner-Ville distribution in support of machinery monitoring and diagnostics

    The Pseudo Wigner-Ville Distribution is a signal transformation of an input time signal into a joint time-frequency domain, that provides an excellent characterization of an input signal as well as its respective energy content. A smoothing window and energy sensitivity analysis of the discretized …

    nps Repository record for An energy analysis of the pseudo Wigner-Ville distribution in support of machinery monitoring and diagnostics (opens in a new tab)

  4. Autonomous non-linear classification of LPI radar signal modulations

    … parameters of the modulation. These include the Wigner-Ville distribution, the Choi-Williams distribution and quadrature mirror filtering. Autonomous time-frequency image cropping algorithm is followed by a feature extraction algorithm based on principal components analysis. Classification …

    nps Repository record for Autonomous non-linear classification of LPI radar signal modulations (opens in a new tab)

  5. Time frequency domain distribution and its application to reciprocating machinery analysis

    … transient. This study proposes the use of Pseudo Wigner-Ville Distribution and introduces Wavelet analysis as two advanced methods for condition monitoring of non-stationary and transient shipboard machinery. These methods employ a time-frequency domain distribution for the detection of fault …

    nps Repository record for Time frequency domain distribution and its application to reciprocating machinery analysis (opens in a new tab)

  6. Analysis of digital communication signals and extraction of parameters

    … methods utilize modified time- frequency distributions, where one of these is based on the Wigner-Ville Distribution (WVD). Gaussian white noise is added to the signal to simulate various signal-to-noise ratios (SNRs)

    nps Repository record for Analysis of digital communication signals and extraction of parameters (opens in a new tab)

  7. DEVELOPMENT OF AN ISAR IMAGING ALGORITHM

    A radar image is the spatial distribution of reflectivity corresponding to the object. An essential requirement for producing a high-quality image is the system resolution, both in range and azimuth directions. In this project, an Inverse Synthetic Aperture Radar (ISAR) imaging algorithm has been …

    nus Repository record for DEVELOPMENT OF AN ISAR IMAGING ALGORITHM (opens in a new tab) Download file for DEVELOPMENT OF AN ISAR IMAGING ALGORITHM (opens in a new tab)

  8. Instantaneous Power Spectrum

    … of the data was recognized as early as 1946. The Wigner-Ville Distribution (WD) has been extensively used since its introduction in 1948, but suffers from some associated problems (e.g., spectral cross-terms and requiring the use of analytic signals). An alternative Distribution is proposed, which …

    nps Repository record for Instantaneous Power Spectrum (opens in a new tab)

  9. Instantaneous Power Spectrum

    … moderate success. Of the many time frequency distribution functions used in the signal analysis, none present fully satisfactory spectra. The performance of the spectrogram, Instantaneous Power Spectra (IPS) the Wigner-Ville Distribution (WD) and various aspects of the Rihaczek distribution …

    nps Repository record for Instantaneous Power Spectrum (opens in a new tab)

  10. Enhanced detection of orthogonal radar waveforms using time-frequency and bi-frequency signal processing techniques

    … PACF and PAF characteristics are quantified. The Wigner-Ville distribution (WVD) and quadrature mirror filter bank (QMFB) timefrequency signal processing techniques and the cyclostationary bi-frequency technique (often used in non-cooperative intercept receivers) are used to detect the orthogonal …

    nps Repository record for Enhanced detection of orthogonal radar waveforms using time-frequency and bi-frequency signal processing techniques (opens in a new tab)

  11. Radar-based analysis approach for the characterization of plasma turbulence in the ionosphere

    … theory through utilizing quadric time-frequency distributions, specifically the Wigner-Ville Distribution. This analysis approach allows one to analyze the backscattered energy as a function of time at an inter-pulse level. The resulting fine time resolution allows me to observe the flow of …

    bu Repository record for Radar-based analysis approach for the characterization of plasma turbulence in the ionosphere (opens in a new tab)

  12. Time frequency analysis of the electromyogram during fatigue

    … through time. Three types of time frequency distributions were applied to the EMG signal As predicted, differences existed between the distributions. The amplitude differential from the first time slice of the distribution to the last was the smallest for the STFT distribution. The …

    njit Repository record for Time frequency analysis of the electromyogram during fatigue (opens in a new tab)

  13. Estimation and Classification of Non-Stationary Processes : Applications in Time-Frequency Analysis

    … non-stationary signals where the spectral power distribution may change with respect to time. Here, we are interested in finding time-frequency representations (TFR) of the signal which can depict how the frequencies and corresponding amplitudes change.In Paper A, we consider the estimation of …

    lund Repository record for Estimation and Classification of Non-Stationary Processes : Applications in Time-Frequency Analysis (opens in a new tab) Download PDF for Estimation and Classification of Non-Stationary Processes : Applications in Time-Frequency Analysis (opens in a new tab)

  14. Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone

    … to S2 sounds, extraction of Smoothed Pseudo Wigner-Ville distribution is used to extract S2 time split and to identify type of S2 splitting. Healthy subjects had SCG S2 time splits range agreeing with S2 time splits from past literature from PCG signals. The ACM SCG signal was also used to …

    gatech Repository record for Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone (opens in a new tab)

  15. Spectral Analysis for Signal Detection and Classification : Reducing Variance and Extracting Features

    … instantaneous frequencies and cross-terms in the Wigner-Ville distribution, the other for signals with an unknown number of short duration oscillations that detects the instantaneous frequencies in a reassigned spectrogram. This thesis also presents two multitaper methods that reduce the influence …

    lund Repository record for Spectral Analysis for Signal Detection and Classification : Reducing Variance and Extracting Features (opens in a new tab) Download PDF for Spectral Analysis for Signal Detection and Classification : Reducing Variance and Extracting Features (opens in a new tab)

  16. Tracking Rhythmicity in Biomedical Signals using Sequential Monte Carlo methods

    … (HMM), short time Fourier transform (STFT), and Wigner-Ville distribution to solve this problem. Recently, a few groups of researchers have proposed Monte Carlo methods which estimate the posterior distribution of the fundamental frequency in multi-harmonic signals sequentially. However, …

    portland-state Repository record for Tracking Rhythmicity in Biomedical Signals using Sequential Monte Carlo methods (opens in a new tab)

  17. Space/time/frequency methods in adaptive radar

    … frequency of a linear FM signal (chirp). The Wigner-Ville distribution, the Gabor expansion, the Short-Time Fourier transform and the Continuous Wavelet Transform are compared with respect to their performance in noisy SAR data to estimate the instantaneous Doppler frequency of range …

    njit Repository record for Space/time/frequency methods in adaptive radar (opens in a new tab)

  18. Seismic Performance of Corroded RC Bridge Piers: A Large-Scale Shaking Table Study

    … to investigate the effects of corrosion distribution. With the experimental data, a rapid damage assessment method based on time-frequency analysis (i.e. Wigner-Ville distribution and Hilbert transform) is proposed. This non-parametric method only relies on input and output acceleration …

    bristol Repository record for Seismic Performance of Corroded RC Bridge Piers: A Large-Scale Shaking Table Study (opens in a new tab) Download PDF for Seismic Performance of Corroded RC Bridge Piers: A Large-Scale Shaking Table Study (opens in a new tab)

  19. Electrophysiological Recording of the Brain, Visualization, Prediction, and Interconnectivity

    … resolution than previously possible. The use of Wigner-Ville distribution together with chirplet decomposition allows a clearer visualization in terms of both the temporal and frequency details with detail higher than previously achieved using other methods including Choi-Williams and …

    toronto-retro Repository record for Electrophysiological Recording of the Brain, Visualization, Prediction, and Interconnectivity (opens in a new tab)

  20. Design of magneto-inductive waveguide for sensing applications

    … which are monitored and processed by Smoothed Wigner-Ville distribution (WVD) to extract time-of-flight for frequency components in the narrow passband. The transmission and reflection coefficients of MI waves are also investigated based on the lumped-element circuit model of the array. Based …

    texas Repository record for Design of magneto-inductive waveguide for sensing applications (opens in a new tab)

Page 1 of 2