Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Wilson plot"”

  1. The effect of a novel coating technique on filmwise and dropwise condensation of steam on horizontal tubes

    … coefficient was determined from the modified Wilson Plot Technique. A hydrophobic coating of a self-assembling monolayer (SAM) with a composition of HS(CH2)15 CH3 promoted excellent dropwise condensation (DWC) on tubes. Coexisting strips with varying widths of filmwise condensation (FWC) and …

    nps Repository record for The effect of a novel coating technique on filmwise and dropwise condensation of steam on horizontal tubes (opens in a new tab)

  2. Experimental and modeling studies in membrane distillation

    … hot brine and cold distillate flow rates by the Wilson plot technique. Membrane properties such as the maximum pore size and tortuosity are characterized and employed in checking out model assumptions and model results for water vapor transport in the Knudsen regime and the transition region. …

    njit Repository record for Experimental and modeling studies in membrane distillation (opens in a new tab)

  3. The influence of fin height and wall conductivity on integral-fin tubes during steam condensation

    … coefficient, Uo, then by using the Modified Wilson Plot Technique. The results indicated that the performance of a finned tube is very dependent on fin height and tube material. Moreover, the results were compared with the predictive models of Beatty and Katz, Rose, Adamek and Webb, and Honda …

    nps Repository record for The influence of fin height and wall conductivity on integral-fin tubes during steam condensation (opens in a new tab)

  4. Effect of fin height on film condensation of steam on stainless steel integral-fin tubes

    … was then determined using the modified Wilson plot technique. A fin height of approximately 0.30 mm provided the maximum heat transfer at both vacuum and atmospheric conditions. Heat transfer performance declined steadily for further increases in fin height. The experimental results were …

    nps Repository record for Effect of fin height on film condensation of steam on stainless steel integral-fin tubes (opens in a new tab)

  5. An experimental study of filmwise condensation on horizontal enhanced condenser tubing

    … transfer coefficients were determined using the Wilson plot technique. The cooling water pressure drop was measured inside the tube and converted to the friction factor in the enhanced section. The overall heat transfer coefficients of the enhanced tubes were increased as much as 1.9 times, and …

    nps Repository record for An experimental study of filmwise condensation on horizontal enhanced condenser tubing (opens in a new tab)

  6. An experimental comparison of enhanced heat transfer condenser tubing.

    … transfer coefficients were determined using the Wilson plot technique. Friction factor in the enhanced section was determined from the cooling water pressure drop. Enhanced geometries (utilizing pitch, helix angle and groove depth) were found to improve the corrected overall heat transfer …

    nps Repository record for An experimental comparison of enhanced heat transfer condenser tubing. (opens in a new tab)

  7. The influence of wall conductivity on film condensation with integral fin tubes

    … (ho) was obtained utilizing a modified Wilson Plot procedure. Results indicated that the performance of a finned tube was strongly dependent on the tube material and weakly dependent on fin geometry. Radiussing the fin root to remove condensate between fins in the unflooded portion (ie, …

    nps Repository record for The influence of wall conductivity on film condensation with integral fin tubes (opens in a new tab)

  8. An experimental investigation of the effect of condensate inundation on heat transfer in a horizontal tube bundle.

    … transfer coefficients were determined using the Wilson plot technique. Observation of condensate flow showed lateral droplet motion along the tube in portions of the condenser as well as side drainage, particularly over the first three tubes. Outside heat transfer coefficients were lower than …

    nps Repository record for An experimental investigation of the effect of condensate inundation on heat transfer in a horizontal tube bundle. (opens in a new tab)

  9. Enhanced condensation of R-113 on a small bundle of horizontal tubes

    … transfer coefficient and then using a modified wilson plot procedure. great care was taken to ensure the results were not vitiated by the presence of non condensibles. results obtained with smooth copper tubes are in agreement with published data and verify satisfactory operation of the test …

    nps Repository record for Enhanced condensation of R-113 on a small bundle of horizontal tubes (opens in a new tab)

  10. Filmwise condensation of steam on horizontal corrugated and wire-wrapped corrugated tubes

    … U(sub O)o, and then utilizing a modified Wilson Plot procedure. Results obtained for steam condensation indicate that the MHT Korodense titanium tube provides negligible enhancement compared to the a titanium tube. The addition of wire-wrapping provided minimal increase in the outside heat …

    nps Repository record for Filmwise condensation of steam on horizontal corrugated and wire-wrapped corrugated tubes (opens in a new tab)

  11. Filmwise condensation of steam on horizontal wire-wrapped smooth and roped titanium tubes

    … The data reduction technique used to modified Wilson plot. Results obtained for the wire-wrapped smooth titanium tubes showed a maximum enhancement of 30% as compared to a smooth titanium tube. This was for a tube using a 0.5 mm wire diameter (P/D(w) = 7.92), corresponding to a fraction of the …

    nps Repository record for Filmwise condensation of steam on horizontal wire-wrapped smooth and roped titanium tubes (opens in a new tab)

  12. An experimental study of dropwise condensation on horizontal condenser tubes

    … coefficients were determined by using the Wilson Plot technique. Of the commercial fluorocarbon coatings, the "Nedox" coating on a copper-nickel tube enhanced the outside heat transfer coefficient by 53% and improved the corrected overall heat transfer coefficient by 27%. Of the sputtered …

    nps Repository record for An experimental study of dropwise condensation on horizontal condenser tubes (opens in a new tab)

  13. The effect of condensate inundation on condensation heat transfer in tube bundles of marine condensers

    … transfer coefficients were determined using the Wilson plot technique. Observation of condensate flow showed lateral droplet motion along the first three tubes in portions of the condenser under all conditions tested. Side drainage occurred only over the third and fourth tubes at a condensation …

    nps Repository record for The effect of condensate inundation on condensation heat transfer in tube bundles of marine condensers (opens in a new tab)

  14. Development and characterization of composite membranes for use in countercurrent solvent extraction

    … prefers both phases almost identically. The Wilson-plot method is used to characterize the membrane resistances as well as the individual-phase boundary layer resistances for each extraction system. The potential practical utility of the MSX technique will be substantially enhanced via Janus …

    njit Repository record for Development and characterization of composite membranes for use in countercurrent solvent extraction (opens in a new tab)

  15. Annular heating probes in oil fouling : effects of wall shear stress

    … temperatures were determined to be low by Wilson-plot calibration and heat conduction calculations. Probe #2, with an improved design, showed lower internal thermal resistance, and hence higher surface temperature at a given power. As fouling was detected in one experiment, this probe …

    ubc Repository record for Annular heating probes in oil fouling : effects of wall shear stress (opens in a new tab)

  16. Pool boiling of R-134a and R-123 on smooth and enhanced tubes

    … step in this study was performing a modified Wilson plot analysis, once completed, the average and local refrigerant heat transfer coefficients were determined. This thesis also presents the enthalpy-based heat transfer analysis (EBHT), a new method for determining the heat exchanger's overall …

    ksu Repository record for Pool boiling of R-134a and R-123 on smooth and enhanced tubes (opens in a new tab)

  17. The condensation of hydrocarbons in a vertical reflux condenser tube

    … coefficient in the reflux condenser based on the Wilson plot method. The composition of binary liquid mixture samples from the test facility was determined using an empirical correlation developed using density measurements from a vibrating u-tube densitometer. The single components were condensed …

    strathclyde Repository record for The condensation of hydrocarbons in a vertical reflux condenser tube (opens in a new tab)

Page 1 of 2