Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"X Nuclei"”

  1. Magnetic resonance with para-hydrogen induced polarisation of x-nuclei

    … hyperpolarisation, hyperpolarisation of its 19F nuclei is evaluated under SABRE. Polarisation levels of −106-fold and 0.85 ± 0.53-fold for 5-fluorouracil were achieved for 1H and 19F, respectively. This work was expanded to include other fluorinated N-heterocyclic compounds including, …

    whiterose Repository record for Magnetic resonance with para-hydrogen induced polarisation of x-nuclei (opens in a new tab)

  2. Advanced spectroscopic imaging techniques for X-nuclei cardiac magnetic resonance imaging

    <p>Changes to cardiac metabolism are an important component of heart failure. Understanding these metabolic changes is therefore critical to developing treatments for the failing heart, particularly pharmaceuticals, or other interventions, which aim to restore normal metabolism. A combination of …

    oxford Repository record for Advanced spectroscopic imaging techniques for X-nuclei cardiac magnetic resonance imaging (opens in a new tab)

  3. Simulation and development of RF resonators for preclinical and clinical 1H and X-nuclei MRI

    Magnetic resonance imaging (MRI) is a unique imaging modality since it provides high soft tissue contrast without ionizing radiation. MRI hardware technology has evolved towards high channel receive (Rx) systems and highly efficient and homogeneous transmit (Tx) coils both increasing image quality …

    heid-diss Repository record for Simulation and development of RF resonators for preclinical and clinical 1H and X-nuclei MRI (opens in a new tab)

  4. Development of X-nuclei hyperpolarised contrast agents for magnetic resonance imaging using dynamic nuclear polarisation

    … to other compounds for their development as X-nuclei HCAs and provide a framework to acquire new, clinically relevant information and widen the applications of hyperpolarised MRI.</p>

    oxford Repository record for Development of X-nuclei hyperpolarised contrast agents for magnetic resonance imaging using dynamic nuclear polarisation (opens in a new tab)

  5. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  6. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  7. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  8. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  9. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  10. System Design for Broadband Magnetic Resonance Imaging and Spectroscopy

    Despite early popularity of X-nuclei magnetic resonance (MR) acquisitions, much of conventional hardware focuses on a proton-centric model. This likely stems from the intrinsically low signal observed from the X-nuclei as attributed by their physical properties and lower relative sensitivity as …

    tamu Repository record for System Design for Broadband Magnetic Resonance Imaging and Spectroscopy (opens in a new tab) Embargoed until 2027-08-01

  11. Development of novel radiofrequency coils for hyperpolarized magnetic resonance imaging

    … <p>X-nuclear MRI, investigating non-proton ‘X-’ nuclei, provides unique metabolic information in vivo. Compared to conventional proton MRI scans, X-nuclei scans are performed at a different range of RF frequencies, therefore requiring special RF coils. However, due to limited wideband power …

    oxford Repository record for Development of novel radiofrequency coils for hyperpolarized magnetic resonance imaging (opens in a new tab)

  12. Increasing the Efficiency of Detecting and Analyzing NMR-based Biomarkers of Disease

    … hydrogen (¹H) in the body. The use of non-¹H nuclei, or X-nuclei, holds promise for enhancing the study and evaluation of disease by providing biochemical information that is complementary to ¹H imaging. However, the implementation of X-nuclei MRI/S is challenging due to their inherent low …

    tamu Repository record for Increasing the Efficiency of Detecting and Analyzing NMR-based Biomarkers of Disease (opens in a new tab)

  13. Triple-Tuned Radiofrequency Coil Designs for Magnetic Resonance Imaging and Spectroscopy

    … but the theoretical sensitivity gains for the X-nuclei frequencies could not be fully resolved. The parallel trap network was compared to both a double- and triple-tuned series trap designs. X-nuclei sensitivities were close in both the double- and triple-tuned reference coils, indicating the …

    tamu Repository record for Triple-Tuned Radiofrequency Coil Designs for Magnetic Resonance Imaging and Spectroscopy (opens in a new tab)

  14. An integrated approach to hyperpolarised magnetic resonance

    … signals from the water/fat pool. Successful X-nuclei imaging utilised hyperpolarised 13C-nicotinamide (via SABRE & dissolution Dynamic Nuclear Polarisation, d-DNP). d-DNP achieved 13C polarisation levels of 13% (with apparent 15 s T1) permitting easy detection in an in vivo cancer model. …

    whiterose Repository record for An integrated approach to hyperpolarised magnetic resonance (opens in a new tab)

  15. Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI

    … stage today, wherein one can scan multiple nuclei, such as 1H and 13C, at various B0 strengths, ranging from 0.05 T to 11.7 T. Each of these nuclei and B0 fields constitutes different Larmor frequencies, which can range from a few MHz to 0.5 GHz. While designing systems or performing …

    tamu Repository record for Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI (opens in a new tab) Embargoed until 2027-12-01

  16. Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI

    … stage today, wherein one can scan multiple nuclei, such as 1H and 13C, at various B0 strengths, ranging from 0.05 T to 11.7 T. Each of these nuclei and B0 fields constitutes different Larmor frequencies, which can range from a few MHz to 0.5 GHz. While designing systems or performing …

    tamu Repository record for Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI (opens in a new tab) Embargoed until 2027-12-01

  17. Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI

    … stage today, wherein one can scan multiple nuclei, such as 1H and 13C, at various B0 strengths, ranging from 0.05 T to 11.7 T. Each of these nuclei and B0 fields constitutes different Larmor frequencies, which can range from a few MHz to 0.5 GHz. While designing systems or performing …

    tamu Repository record for Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI (opens in a new tab) Embargoed until 2027-12-01

  18. Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI

    … stage today, wherein one can scan multiple nuclei, such as 1H and 13C, at various B0 strengths, ranging from 0.05 T to 11.7 T. Each of these nuclei and B0 fields constitutes different Larmor frequencies, which can range from a few MHz to 0.5 GHz. While designing systems or performing …

    tamu Repository record for Approaches to B1 Mapping and Calibration for Multi-Nuclei MRI (opens in a new tab) Embargoed until 2027-12-01

  19. Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS

    … studies are common, the interest in other X-nuclei has grown rapidly. However, limited support from existing MR systems and the challenges in designing multinuclear RF coils hinder these studies. This dissertation proposes a multinuclear RF coil setup and implements two system modification …

    tamu Repository record for Hardware Approaches for Enabling Multi-Channel Multinuclear MRI/MRS (opens in a new tab)

Page 1 of 2