Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 169 for “"X-Ray micro-Computed tomography"”
-
Structure characterisation of catalysts using x-ray micro-computed tomography
Knowledge of internal porous structure is essential in improving the development of a catalytic system and consequently leading to an optimized performance. XRCT has been used to show differences in density and pore distribution and that differences can be related to the process route by which the …
-
Efficient sampling strategies for x-ray micro computed tomography with an intensity-modulated beam
… sampling strategies that can be applied to x-ray micro-computed tomography (CT) systems which operate with an intensity-modulated beam. Such a beam can be employed to provide access to a phase contrast channel and high spatial resolutions (a few um). Phase contrast can offer better image …
-
Structural Mapping of Paper Towels: Comparison of Twin Laser Profilometry and Synchrotron X-ray Micro-computed Tomography
… Twin Laser Profilometry (TLP) and synchrotron X-ray micro-computed tomography (XRμCT). The thickness and out-of-plane deformation (OPD) distributions were mapped using a TLP and XRμCT. The XRμCT samples were further used to calculate for the mass center surface. TLP enables web structures to be …
-
Image-based characterization of low-plastic silt matrix for fabric quantification using x-ray micro computed tomography
… been rarely undertaken. This study employed X-ray micro CT to investigate silt-sized particles to bridge this gap, focusing on systematic particle fabric quantification within a silt matrix. Due to the lack of previous experimental knowledge for micro CT imaging of silts, material-specific …
-
Characterization of porous transport layers of polymer electrolyte membrane fuel cells using X-ray micro-computed tomography
… of polymer electrolyte membrane fuel cells, X-ray micro-computed tomography (X-µCT) imaging has been recognized as a viable tool. This method provides the 3D structure of materials with a high resolution. Despite the general success of X-µCT, the following topics have not been explored: first, …
-
The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings
… strain distribution using synchrotron X-ray microtomography (SX μCT) coupled with digital volume correlation (DVC). The forcebalance method relates the creep in bondcoats of precision-machined cylindrical micro-specimens to the stress acted on the bondcoat by the TGO. These …
-
Optimization of potato quality and energy consumption under different drying methods: multivariate modelling using 3D X-ray micro-computed tomography
… quality of potatoes. Using non-destructive X-ray microtomography, the study analyzed the microstructural transformations of dried potato samples and was used to correlate these changes with quality attributes. The research introduced a new Hybrid Quality Score Evaluator (HQSE) to assess the …
-
Structure Pharmaceutics Based on Synchrotron Radiation X-Ray Micro- Computed Tomography: From Characterization to Evaluation and Innovation of Pharmaceutical Structures
… the quaternary level is defined as the meso or micro scale architecture of active and non-active molecules within a DDS with sizes from Å to μm for the molecular structure of drug and excipients. Methods combining X-ray tomography, image processing, and 3D reconstructions have been devised and …
-
X-ray micro computed tomography-based characterization of bead microstructure in polymer composite large area additive manufacturing : analysis, simulation, and experimentation.
… requires a comprehensive understanding of the microstructure, including micro voids, fibers, and the interactions between them, as these factors significantly influence the mechanical properties of the final parts. Researchers have addressed manipulating manufacturing process parameters …
-
In-situ visualization and characterization of mud-filtrate invasion and filter cake deposition using time-lapse X-ray micro-computed tomography (micro-CT)
… properties. Using high-resolution X-ray micro-computed tomography (micro-CT), we were able to visualize and characterize mudcake deposited on the borehole wall and the distribution of mud filtrate in the core samples as a function of both space and time during the experiments. …
-
X-ray tomography investigation of the impact damage mechanisms of thin-ply composites and the use of veils to improve their impact tolerance
… techniques such as nanometric-resolution X-ray micro-computed tomography. Overall, we gave a step forward towards the inclusion of thin-ply laminates in new commercial aircraft designs
-
Analysis of tumour angio-architecture and blood flow using microcomputed tomography and lattice Boltzmann simulations.
… angiogenic signalling prevalent in the tumour microenvironment. Aberrant tumour vasculature is a key determinant of spatial and temporal heterogeneities of blood flows. Additionally, irregularities in the tumour vascular wall, a lack of functional lymphatics and a severely retarded trans-mural …
-
Ichnology, sedimentology, stratigraphy, and trace fossil-permeability relationships in the Upper Cretaceous Medicine Hat Member, Medicine Hat gas field, southeast Alberta, Canada
… on the reservoir characteristics was assessed. X-ray micro-computed tomography was conducted on four samples from a reservoir interval to visualize the geometry and distribution of burrow-associated heterogeneity. The results demonstrate that planiform bioturbate textures locally enhance the …
-
A geometric study of liquid retention in open-cell metal foams
… dip tests and geometrical classification via X-ray Micro-Computed Tomography. Aluminum open-cell metal foam samples of 5, 10, 20, and 40 pores per inch (PPI), all having a void fraction greater than 90%, were included in this investigation. In order to model the condensate retention behavior of …
-
REPRESENTATIVE VOLUME ELEMENT BASED MICROMECHANICAL MODELING OF BIOMEDICALLY RELEVANT COMPOSITE MATERIALS
Micromechanical modeling of composite materials is an efficient and adaptable tool utilized to predict the overall behavior of composites, understand its correlation with the microstructure, and to develop new materials with superior mechanical and physical properties. One of the applications of …
-
Morphology, Ontogeny, and Phylogenetic Relationships of the Permo-Carboniferous tetrapod Brachydectes newberryi from the Council Grove Group, Nebraska, USA
… ancestors. I used high resolution x-ray micro-computed tomography (HR-XCT) to study skulls of the lysorophian Brachydectes newberryi from the Early Permian of Kansas and Nebraska, USA. I present a detailed description of the skeletal morphology of these skulls, including fine …
-
Petrophysical Properties of the HED Meteorites and the Bushveld Igneous Complex: Implications for Future Asteroid Prospecting Missions
… helium pycnometry, the Archimedean method, and X-ray micro-computed tomography), magnetic susceptibility, induced polarization and resistivity, and P-wave velocity. Mineralogical methods in this work include optical microscopy, micro X-ray diffraction, micro X-ray fluorescence element mapping, and …
-
(U-Th)/He Thermochronology of the Ottawa Embayment, Eastern Canada: the Temperature-time History of an Ancient, Intracratonic Rift Basin
… thermochronometry, raman spectroscopy and x-ray micro-computed tomography. We then integrate our thermochronology data with regional geology to utilize multi-sample numerical modelling to improve our understanding of the thermal history of the Ottawa Embayment and the evolution of …
-
Environmental Degradation of Carbon Fibre-Reinforced Epoxy Composites: An Experimental Investigation
… beam strength. Secondary testing, including microscopy, x-ray micro-computed tomography and thermal analysis, was performed to further characterize degradation.It was demonstrated that significant mechanical and physical degradation resulted from exposure to deionized and ocean water, but not …
Page 1 of 9