Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 21 for “"X-ray CT imaging"”.
-
Nanoparticles as X-ray CT Imaging Contrast Agents in Saturated Porous Media
Parallels exist between medical imaging techniques, such as X-ray computed tomography (CT) or magnetic resonance imaging, and geophysical methods used to analyze the subsurface, such as ground penetrating radar, electromagnetic induction, magnetic susceptibility, or nuclear magnetic resonance. …
-
Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization
… contributes toward solutions to two distinct problems linked through the use of common information optimization methods. The first problem is the X-ray computed tomography (CT) imaging problem and the second is the computation of Berger-Tung boundsfor the lossy distributed source coding …
-
Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry
Polymer gel dosimetry, in conjunction with x-ray computed tomography (x-ray CT) imaging, is a three-dimensional dosimetric tool that shows promise in the verification of complex radiation therapy treatments. Previous studies have shown that x-ray CT imaging of gel dosimeters is robust, easy-to-use, …
-
Computational linear shift-invariant imaging with periodic point spread function
Lens based imaging systems are shift-variant and suffer from limited depth of field. However, the majority of image processing applications are based on a linear shift-invariant model. In order to satisfy such a model, a few constraints have to be imposed. For instance, the linear shift-invariant …
-
Read-out electronics for a single photon emission computed tomography (SPECT) small animal imaging system
<p>Read-out electronics have been designed for a new single photon emission computed tomography (SPECT) system. The SPECT system was incorporated into the existing Oak Ridge National Laboratory's MicroCAT X-ray CT imaging system for the purpose of complete dual-modality small animal imaging. Data …
-
A low-noise, wide-band CMOS charge-sensitive preamplifier for use with a cadmium zinc telluride strip detector in a high-resolution small animal x-ray CT system
… with a Cadmium Zinc Telluride (CZT) strip detector in the Oak Ridge NationalLaboratory's (ORNL) MicroCAT small animal x-ray CT imaging system. The Characteristics of the CZT strip detector have been studied to optimize the design of the preamplifier, and are presented herein. The design of the …
-
Applications of Statistical Modeling in Iterative CT Image Reconstruction
Traditionally, x-ray CT images are produced by an algorithm called filtered back projection, or FBP. FBP is an analytical solution to the idealized CT image reconstruction problem, the inverse problem of turning raw x-ray measurements into a full 3-dimensional (3D) image, and is derived assuming a …
-
Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters
… gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results indicate that both diffusion and …
-
Using X-ray computed tomography to measure local gas holdup in a stirred tank reactor
… estimation, and scale-up of stirred tank reactors (STRs). In the present work, local gas holdup is measured in an acrylic stirred tank reactor equipped with a Rushton impeller using X-ray computed tomography (CT) for many different operating conditions. Power consumption for different …
-
Task-Based Image Quality Assessment in X-Ray Computed Tomography
In X-Ray CT, there is always a desire to maintain the image quality while reducing the radiation dose. Recently several dose reduction approaches in both software and hardware have been developed to achieve the goal of making radiation as low as possible. Thus, the assessment of image quality …
-
Investigation of sub-core scale fluid flow behaviour within heterogeneous sandstones : the role of deformation bands
… sandstones, is poorly understood. Internal structure of small-scale heterogeneities is investigated with X-ray computed tomography (CT). To this aim, high-resolution, artefacts-free CT images are needed. Beam hardening artefact, in cylindrical-shaped samples, increases the X-ray attenuation …
-
Development of Novel Tools for Stochastic Multiscale Finite Element Analysis of Composite Structures
… (FEA) framework for investigating the structural performance of unidirectional and multi-directional textile fibre reinforced polymer (FRP) composites is presented. The framework enables studying global (stiffness) and local responses (strength) under the influence of geometric and material …
-
Towards Modeling Projectile Penetration in Dry and Multiphase Granular Materials
… modeling strategies in granular materials impacted by a projectile. The focus is on two regions: (a) near-field: region near the tip and along the path of a projectile where comminution of grains is significant, (b) intermediate-field: region far from the projectile where grain-scale …
-
Mechanical behavior of fibrous root-inspired anchorage systems
… or enhance conventional geotechnical infrastructure. In particular, the anchorage and material efficiency attributes of fibrous root systems are encapsulated in a novel root-inspired anchor that has the capability of surpassing conventional anchorage systems (e.g. tiebacks, tiedowns, plate and …
-
Deep learning in lung cancer pre- and post-radiation therapy: diagnosis of malignancy and radiation-induced lung injury from 3D x-ray CT.
… mortality worldwide, with early detection and accurate diagnosis being critical for improving patient outcomes. Additionally, the progression of Radiation-Induced Lung Injury (RILI) following Stereotactic Body Radiation Therapy (SBRT) for lung cancer presents a significant diagnostic …
-
Fracture Energy Measurement of Rocks Using the Direct Tension Test
Understanding tensile fracture in rocks is fundamental to geotechnical engineering, where brittlefailure strongly influences the stability and performance of underground structures. Mode-I fracture is the primary mode for characterizing tensile strength, fracture energy, and fracture process zone …
-
Nondestructive evaluation of fresh chestnut internal quality using x-ray computed tomography (CT)
… It is problematic for the industry, and impacts consumer satisfaction, shelf life, and proper storage. Currently, destructive techniques can be employed to evaluate fresh chestnut internal quality. However, clearly not all produce can be evaluated. In commercial situations, decayed chestnuts …
-
Photon-Counting Micro-CT: Algorithm Development and Application in Mouse Models of Disease
<p>Over the past fifty years, x-ray computed tomography (CT) has become a widely used imaging modality in medical applications due to its fast scanning speed and high spatial resolution. However, the contrast and energy resolution of CT has been limited by the use of energy-integrating detectors …
-
Discrete Element Modeling of the Grading- and Shape-Dependent Behavior of Granular Materials
… and morphological features of and the interactions among constituent particles at the microscopic scale. From a modeling standpoint, the particle-based discrete element method (DEM) has emerged as the most prevalent numerical tool to model and study the behavior of granular materials and the …
-
Synthesis, design and fabrication of microwave filters and multiplexers
… implementation of microwave filters using Selective Laser Melting (SLM) and Micro Laser-Sintering (MLS) based 3-D printing technologies. The thesis contains six projects. The first project proposes a synthesis and design approach for filters with multiple transmission zeros generated using …
Page 1 of 2