Showing 1 to 20 of 34 for “"X-ray Phase Contrast Imaging"”.
-
Development of X-ray phase-contrast imaging techniques for medical diagnostics
The X-Ray phase-contrast techniques are innovative imaging methods allowing overtaking the limitations of classic radiology. In addition to the differential X-ray absorption on which standard radiology relies, in phase-contrast imaging the contrast is given by the effects of the refraction of …
-
Contributions to the characterization of grating-based x-ray phase-contrast imaging
… and optimization of the grating-based x-ray imaging technique is presented. The investigations are introduced by analytical considerations, are underpinned with numerical simulations and validated using exemplary experiments. A detailed examination of the image formation in a grating …
-
Grating Technology and System Development for High-Resolution X-Ray Phase-Contrast Imaging
X-ray imaging is a workhorse of medical imaging, and in particular, high-resolution X-ray imaging is used in the detection of carcinomas and micro-calcifications in the breast, small fractures, and early stages of cancerous tumors. In addition, high-resolution X-ray imaging is essential for …
-
On the nature of dynamic cavity collapse using x-ray phase contrast imaging
… in fluids through established high-speed optical imaging techniques. However, capturing cavity collapse in solid media has remained elusive, due to the difficulties that even transparent solids pose in using visible light illumination. In this work cavities in the solid polymer poly[methyl …
-
Developing a Microbubble-based Contrast Agent for X-ray Phase Contrast Imaging to Detect Neovasculature in Breast Cancer
X-ray phase contrast imaging (XPC) generates contrast from refraction and scattering of X-rays, unlike absorption in conventional radiology. This technique greatly improves the sharpness of boundaries and reveals micro-structured tissues that are not easily detected by conventional absorption-based …
-
Development of 3D x-ray phase-contrast Imaging and analysis tools for tubular and branching structures with applications in colorectal cancer research.
X-ray micro-computed tomography (μCT) is a non-destructive imaging technique used to capture the internal three-dimensional (3D) structure of small samples at high spatial resolutions. As it requires a certain level of knowledge in engineering, material science, mathematics and physics, it and can …
-
X-ray phase contrast imaging: Application of Bragg demagnifier optics for imaging of cm-scale objects with km propagation distance within a meter
X-ray phase contrast imaging is effective for visualizing weakly absorbing materials, such as soft tissues, but is often limited by high radiation dose and the need for long propagation distances to achieve sufficient contrast for large samples at moderate resolution. This work presents a compact, …
-
X-Ray Phase Contrast Imaging: Eine systematische Literaturübersicht : deskriptive Beschreibung der Technologie, Gegenüberstellung zur konventionellen Röntgenaufnahmetechnik und deren Anwendungsbereiche mit besonderem Augenmerk auf die Zahnheilkunde
… sehr beschränkt und die Absorption ist mit der Phasenkontrasttechnik zusätzlich sichtbar. <br>Im Bereich der Strahlenbelastung ist meist die XPCI-Methode im Vorteil, manche Versuchsaufbauten erfordern aber höhere Strahlendosen als vergleichbare konventionelle Röntgentechnik. <br>Die …
-
Sub-pixel registration for low cost, low dosage, x-ray phase contrast imaging : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Electronic and Computer Engineering at Massey University, Palmerston North, New Zealand
X-ray phase contrast imaging is an imaging modality that measures the phase shift of the X-ray wavefronts as they travel through different materials. This gives a higher contrast between regions of similar X-ray attenuation, in a medical sense this corresponds to a higher contrast of soft tissues. …
-
DEACCLIMATION IN THREE DIMENSIONS: KINETICS, GENETICS AND MORPHOMETRICS OF COLD HARDINESS LOSS IN GRAPEVINES
… was studied using RNA-Seq; and freezing imaging and microtomography was performed using synchrotron X-ray phase contrast imaging. Deacclimation rates (kdeacc) in several genotypes demonstrated a dependency on chill accumulation (dubbed deacclimation potential; Ψdeacc) that followed a …
-
A multi-scale imaging approach to understand osteoarthritis development
X-ray phase-contrast imaging is an innovative and advanced imaging method. Contrary to conventional radiology, where the image contrast is primarily determined by X-ray attenuation, phase-contrast images contain additional information generated by the phase shifts or refraction of the X-rays …
-
Asymmetric Illumination X-ray Differential Phase Contrast Imaging
… we present a novel, low-cost approach to x-ray phase contrast imaging (XPCI). This method, which we term asymmetric illumination x-ray phase contrast imaging (AIXPCI), is compatible with a broadband tabletop x-ray source in a conventional laboratory setting and utilizes an angular filtration …
-
MICROFABRICATION OF X-RAY OPTICS FOR MICROSCOPY AND PHASE CONTRAST IMAGING
The short wavelength of x-ray radiation (λ = 10Å to λ = 0.1Å) gives it the ability to penetrate deeper into matter and makes it highly useful for applications in microanalysis and imaging, where it is desirable to probe beyond the surface of the material under analysis. Hard x-rays generally refer …
-
New imaging modalities in high resolution X-ray tomography
For more than 100 years, X-rays are used in medical diagnostics, materials science and many other research domains for the possibility they offer to look through objects. Since the 1970s, Computed Tomography or CT allows for acquiring a full 3D representation of an object or a patient. In the …
-
Dynamic properties of boron carbide
… visualizing the failure in real time using x-ray phase contrast imaging (XPCI) at the Advanced Photon Source. However, we can only record 2D images during dynamic loading, as the crack density increases it becomes difficult to track individual defects and understand the failure processes. …
-
Imaging applications from a laser wakefield accelerator
… oscillation and emit synchrotron-like X-ray radiation, commonly known as betatron radiation, in a narrow cone along the laser propagation axis. The properties of both the electrons and the X-rays produced by the LWFA make them excellent candidates for a wide range of applications. In this …
-
Development of X-ray Phase Contrast and Microtomography Methods for the 3D Study of Fatigue Cracks
… a new approach to 3D crack mapping relying on X-ray phase imaging and stereometric approaches. Absorption microtomography was used to determine crack surface positions. Crack opening was measured from absorption microtomography data both before and after crack extension and patterns of opening at …
-
Investigation of alternative jet fuels in gas turbine combustion systems using x-ray radiography
… to conventional jet fuel. In this work, x-ray phase-contrast imaging is performed at 90,517 Hz on a combusting fuel spray in a realistic gas turbine combustor, allowing characterization of breakup process of fuel into ligaments and then individual droplets as it leaves a nozzle. This …
-
Single-shot X-ray Phase Contrast and Dark-field Imaging with a Single-mask Set-up
Traditional X-ray imaging, which relies on attenuation contrast, faces challenges in differentiating materials with similar attenuation coefficients, particularly in soft tissues. X-ray phase contrast imaging (XPCI) and dark-field (DF) imaging address this limitation by detecting phase shifts and …