Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 23 for “"X-ray computed microtomography"”.
-
X-ray computed microtomography applications for complex geometries and multiphase flow
… of producing biased or even incorrect results. Xray techniques, based on synchrotron or laboratory X-ray sources, have attracted the attention of the research and industrial R&D community thanks to their characteristic of having little to no detectable influence on the subject under study. …
-
Numerical Calculation of Transport Properties of Rock with Geometry Obtained Using Synchrotron X-ray Computed Microtomography
… was to develop a workflow using Synchrotron X-ray Computed Microtomography (CMT) images and commercially available software in order to determine the macroscopic properties in reservoir drill cores for Midale Marly (M0) and Vuggy Shoal (V6) rocks. The workflow started by using CMT data that …
-
Petrophysical and geochemical characterization of midale carbonates from the Weyburn oilfield using synchrotron X-ray computed microtomography
… is necessary. In this study, synchrotron-based X-ray computed microtomography (CMT) is being utilized to extract physically realistic images of carbonate rock cores for the evaluation of porosity and mineralogy in the Mississippian Midale beds of the Weyburn Oilfield in southeastern Saskatchewan. …
-
Investigating soil aggregate pore structures and their relationship to bacteria spatial distribution using x-ray computed microtomography
… poorly understood until recent advances of X-ray computed microtomography (μCT) imaging in soils. Overall, the dissertation aims to effectively utilize soil aggregate μCT imaging, to understand soil aggregate structure difference under contrasting land use and managements, and to …
-
Non-destructive tooth cementum annulation based age estimation by (conventional and) phase-sensitive high-resolution X-ray computed microtomography
… and accuracy of phase-contrast synchrotron microtomography (SR-MCT) as a non-destructive alternative to the thin-ground section method and explores the periodicity of cementum apposition to uncover its biological underpinnings. Twenty fresh, single-rooted, permanent teeth (formalin-fixed) …
-
A microtomografia de raios X para o estudo da anatomia da microestrutura de órgãos e suas patologias
Computed microtomography has advanced in the last decades providing an improvement in the quality of the generated images, assisting in several fields of science, especially in studies involving biological samples. X-ray microtomography is a nondestructive technique that makes possible the 3D model …
-
TRACR: a software pipeline for high-throughput materials image analysis--an additive manufacturing study
… the form of images (e.g. optical microscopy, X-ray computed microtomography, scanning electron microscopy, etc.), rapid characterization becomes an image processing problem. Describing the geometry of visually discernible regions of interest in materials image data is an essential step in …
-
Construction of novel tissue engineering scaffolds using supercritical fluid gas foaming
… pore architecture was investigated through X-ray computed microtomography (microCT); the scaffolds were shown to be up to 60% porous with pore diameters in the range of 0.088-0.924 mm (0% silica) to 0.044 – 0.342 mm (33.3% silica), demonstrating that silica controlled both pore size and …
-
The biomechanics of the dipteran wing hinge
… Finally, I utilise time-resolved synchrotron X-ray computed microtomography to visualise the internal musculature of <em>C. vicina</em> during flight, where I assert that several muscles influence wing movements by restricting the motion of wing hinge components. Throughout this thesis, the …
-
Real-time high-temperature 3D imaging of the fracture behaviours in an aerospace-grade ceramic-matrix composite
… CMCs. In this study, <i>in situ</i> X-ray synchrotron computed micro-tomography was utilized to obtain an insightful view of the progressive fracture processes of the 2.5 dimensional SiC<sub>m</sub>/SiC<sub>f</sub> CMC samples under three-point bending test at room temperature (RT) and …
-
Investigation of the high-temperature mechanical behaviour of oxide-oxide ceramic-matrix composites
… temperature mechanical testing with in situ X-ray computed microtomography and digital volume correlation were explored. Subsequently, residual stresses were quantified using photoluminescence piezospectroscopy.<br/>Materials with different sintering temperatures based on Nextel<sup>TM</sup> …
-
Morphological characterization of soft matter systems using advanced 3-dimensional imaging
… the internal structure of the system. Herein, X-ray computed microtomography (µ-CT) coupled with advanced image processing tools is used for extracting detailed microstructural information of foams and emulsions. The derived morphological information is used for evaluating the aging mechanisms of …
-
Mafic Explosive Volcanism at Llaima Volcano: 3D X-Ray Microtomography Reconstruction of Pyroclasts to Constrain Shallow Conduit Processes
… permeability analysis. Here we use synchrotron X-ray computed microtomography of 10 pyroclasts from the 12.6 ka mafic Curacautín Ignimbrite (Llaima Volcano, Chile) to reconstruct and quantify pyroclast textures in three dimensions. Our goal is to obtain 3D measurements of porosity, bubble …
-
Structural characterization of interaction zone between Glass Ionomer Cement and enamel and dentine in human teeth
… microscopy (SEM) with energy dispersive X-ray chemical mapping (EDX) in two dimensions (2D) and by confocal laser scanning microscopy (CLSM), X-ray computed microtomography (µCT), and phase-contrast-enhanced µCT (PCE-CT) in a synchrotron radiation facility in three dimensions (3D). …
-
Effect of Phase Transformation on Stress Redistribution and Damage Evolution During Actuation Fatigue in Shape Memory Alloys
… of this work, SMA actuators are analyzed using X-Ray Computed MicroTomography in order to determine the evolution of internal damage as a function of actuation fatigue life. The data shows that the internal damage evolves in a non-linear manner, with a rapid nucleation of damage at the beginning …
-
Effect of different crop residue management on soil hydraulic properties - a study in a silt loam soil in Belgium
… three different methods in core scale: X-ray computed microtomography (X-ray CT), HYPROP evaporation and Richards pressure plate method to obtain the entire SWRC. The combination of these methods found well justified to obtain the accurate and complete SWRC. Saturated hydraulic …
-
QUANTITATIVE EVALUATION OF THE CONSOLIDATING EFFECTS INDUCED BY INORGANIC MINERAL TREATMENTS APPLIED ON POROUS CARBONATE STONE SURFACES
… imaging, including synchrotron 4D X-ray computed microtomography (SR-μCT), micro-X-ray diffraction (SR-μXRD), and micro-X-ray fluorescence (SR-μXRF). These high-resolution techniques are complemented by laboratory methods for initial assessments. The first manuscript published in the …
-
Využití průmyslové rentgenové počítačové mikrotomografie ve vývojové biologii
Rentgenová počítačová mikrotomografie (CT) je metoda pro trojrozměrné (3D) zobrazování vnitřní struktury objektů. Laboratoř rentgenové počítačové mikro a nanotomografie na CEITEC VUT (Středoevropský technologický institut, Vysoké učení technické v Brně) se zaměřuje zejména na nedestruktivní analýzu …
-
Vyhodnocení ošetření zubních kanálků pomocí rentgenové počítačové mikrotomografie
Práce je věnována zpracování a analýze mikro-CT obrazů zubních kanálků vyplněných dvěma materiály (AH-plus a NaMPC). Proto byla naskenována šestice psích zubů v laboratoři rentgenové počítačové mikrotomografie. Hlavním cílem práce bylo vytvoření algoritmu (v prostředí Matlab) k vyhodnocení kvality …
-
Microstrain Partitioning, TRIP Kinetics and Damage Evolution in Third Generation Dual Phase and TRIP-Assisted Advanced High Strength Steels
… microscopic Digital Image Correlation (µDIC), X-ray Computed Microtomography (µXCT), Electron Backscattered Diffraction (EBSD) and X-ray Diffraction (XRD), all of which can be tracked as deformation proceeds. This PhD thesis uses a novel post µDIC data processing technique to prove that a …
Page 1 of 2