Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 628 for “"X-ray computed."”.

  1. Adaptive X-ray Computed Tomography

    An adaptive pre-clinical x-ray computed tomography system, named "FaCT" was designed, built, and tested at the University of Arizona's Center for Gamma-Ray Imaging (CGRI). The FaCT system possesses the unique ability to change its magnification and dynamically mask the x-ray beam profile. Using …

    arizona-thes Repository record for Adaptive X-ray Computed Tomography (opens in a new tab)

  2. Novel algorithms for X-ray computed tomography

    X-ray computed tomography (CT) is a non-destructive technique for assessing the structural integrity of an object without compromising its usefulness. This imaging modality uses a number of projection measurements of the attenuated X-rays after passing through the object at different angles of …

    msu Repository record for Novel algorithms for X-ray computed tomography (opens in a new tab)

  3. Quadratic Form Minimisation in X-ray Computed Tomography

    The simplest physical model of X-ray attenuation through matter (i.e. Beer's Law) gives rise to a linear equality between a vector of measured attenuations, m, and the projection of an attenuating volume vector x. In equation form, m = Ax where A is determined by the tomographic experiment …

    anu Repository record for Quadratic Form Minimisation in X-ray Computed Tomography (opens in a new tab)

  4. Investigations in x-ray computed tomography polyacrylamide gel dosimetry

    … in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method due to a change in gel density that occurs upon irradiation. The accessibility of CT technology to cancer hospitals makes CT read-out clinically attractive, however the …

    ubc Repository record for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab) Download PDF for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab)

  5. Applications of x-ray computed tomography polymer gel dosimetry

    … must improve to accommodate these advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  6. Hydraulic characterization of structured packing via x-ray computed tomography

    … require non-traditional data for validation. X-ray computed tomography (CT) has been evaluated as one possible technique for measuring local flow behavior in packed columns. X-ray CT was used in this work to obtain images of an operating air-water contactor containing Mellapak 250Y …

    texas Repository record for Hydraulic characterization of structured packing via x-ray computed tomography (opens in a new tab)

  7. 3-D fracture tracing for X-ray computed tomography data

    X-ray computed tomography (CT) is a nondestructive imaging method that shows differences in X-ray attenuation, which is a proxy for density. Sensitivity to density differences makes CT a good choice for imaging open natural fractures because of the significant density contrast between air and rock. …

    texas Repository record for 3-D fracture tracing for X-ray computed tomography data (opens in a new tab)

  8. The Alvarez-Macovski Model and Quantitative X-ray Computed Tomography

    X-ray computed tomography (XCT) is a standard technique of investigating the structure of both people and objects. There is a demand for extracting more quantitative information from XCT, such as density and atomic number. In order to generate physically sensible values for the tomogram voxels, XCT …

    anu Repository record for The Alvarez-Macovski Model and Quantitative X-ray Computed Tomography (opens in a new tab)

  9. Task-Based Image Quality Assessment in X-Ray Computed Tomography

    In X-Ray CT, there is always a desire to maintain the image quality while reducing the radiation dose. Recently several dose reduction approaches in both software and hardware have been developed to achieve the goal of making radiation as low as possible. Thus, the assessment of image quality …

    arizona-thes Repository record for Task-Based Image Quality Assessment in X-Ray Computed Tomography (opens in a new tab)

  10. Instance segmentation and material classification in X-ray computed tomography

    Over the past thirty years, X-Ray Computed Tomography (CT) has been widely used in security checking due to its high resolution and fully 3-d construction. Designing object segmentation and classification algorithms based on reconstructed CT intensity data will help accurately locate and classify …

    bu Repository record for Instance segmentation and material classification in X-ray computed tomography (opens in a new tab)

  11. Void Growth and Coalescence Studied by X-Ray Computed Tomography

    … were investigated by means of in situ X-ray computed tomography coupled with tensile deformation. A variety of model materials were fabricated whereby artificial three dimensional void arrays were embedded in metal matrices. An ultra short-pulsed laser machining system and diffusion …

    mcmaster Repository record for Void Growth and Coalescence Studied by X-Ray Computed Tomography (opens in a new tab)

  12. Development of a low cost x-ray computed tomography system

    Computed Tomography (CT) has been one of the most exciting imaging modalities developed in the biomedical field. Although the problem of imaging and image reconstruction arises in many scientific fields, e.g. astronomy and non-destructive testing, its most prominent applications are found in the …

    msu

  13. ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY

    … distribution acquired from dual-energy x-ray computed tomography (DECT) have been studied in this M.Sc. project. In the study, attenuation coefficient images were generated via computer simulation of a DECT system and compared with the exact attenuation coefficient distributions. The …

    nus Repository record for ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY (opens in a new tab) Download file for ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY (opens in a new tab)

  14. Integrating shape priors to X-ray computed tomography using machine-learning

    … Design (CAD) data priors to infer missing X-Ray measurements instead of sampling them. X-Ray Computed Tomography (XCT) is a non-destructive imaging technique that produces cross-sectional, volumetric images of bodies sensitive to X-Ray. It relies on the repeated sampling of the body from …

    soton Download PDF for Integrating shape priors to X-ray computed tomography using machine-learning (opens in a new tab)

  15. X-ray Computed Tomography Assessment of Air Void Distribution in Concrete

    … cut and polished surfaces. The emergence of X-ray computed tomography (CT) techniques provides the capability of capturing the inner microstructure of materials at the micrometer and nanometer scale. X-ray CTâ s less demanding sample preparation and capability to measure 3D distributions of air …

    toronto-retro Repository record for X-ray Computed Tomography Assessment of Air Void Distribution in Concrete (opens in a new tab)

  16. Image Reconstruction for X-ray Computed Tomography in Security Screening Applications

    X-ray tomographic systems have increasingly widespread use in security screening applications. For example, most major airports now utilize X-ray CT systems for efficient screening of baggage and cargo. While decades of research has benefited CT for medical diagnostics, a number of practical …

    purdue-thes Repository record for Image Reconstruction for X-ray Computed Tomography in Security Screening Applications (opens in a new tab)

  17. Strategies for Temporal and Spectral Imaging with X-ray Computed Tomography

    <p>X-ray micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. This study presents a set of tools that achieve these improvements. These tools …

    duke Repository record for Strategies for Temporal and Spectral Imaging with X-ray Computed Tomography (opens in a new tab)

Page 1 of 32