Showing 1 to 20 of 98 for “"X-ray diffractometer"”.
-
The modification and characterization of an x-ray diffractometer for the study of polymer fibers and films
… were to modify a commercially available X-ray transmission diffractometer assembly for the study of polymer fibers and films and to characterize the instrumental correction factors for the unite The performance of the modified diffractometer was compared to the performance of the …
-
I. Some Quantitative and Qualitative Analytical Applications of a New Geiger Counter X-Ray Diffractometer. Ii. An X-Ray Investigation of Some Unsolved Sugar Problems. Iii. The Reactions of Solutions of Molybdenum-Carbonyl in Oil on Metal Surfaces
Made available in DSpace on 2014-12-05T19:35:48Z (GMT). No. of bitstreams: 1 0007830.pdf: 8291839 bytes, checksum: 1860f1ef9f228fcae72d431c38342a31 (MD5) Previous issue date: 1954
-
Experimental Determination of Smectite Hydration States Under Simulated Diagenetic Conditions (high-Temperature, X-Ray Diffraction, Dehydration)
… environments. A high-pressure high-temperature X-ray cell, mounted on an automated General Electric XRD3 X-ray diffractometer, was used to monitor the basal reflections.
-
Vienfazių SrAl4O7 junginių legiruotų europiu ir disproziu sintezė ir liuminescencinių savybių tyrimas /
… phase was determined by analyzing samples with X-ray diffractometer and luminescent properties were investigated using a spectrophotometer. A series of samples with different europium and dysprosium concentration were synthesized and analyzed. It was determined that 2 % of Eu2+ and 2 % of Dy3+ …
-
Practical Application of Residual Stress Measurements on Maritime Vessels
… examines the practical application of portable X-ray diffraction to measure residual stresses on board active maritime platforms. These measurements will provide better understanding of structural failures in aluminum hulls and superstructures. The feasibility of this process was analyzed by …
-
Crystallographic Studies of Orthorhombic Black Phosphorus at High Temperatures and Pressures
… expansion coefficients of a single crystal by x-ray diffractometer techniques and verifying these results by the x-ray diffractometer method on the powder; (2) measuring the compressibility coefficients by neutron time-of-flight (TOF) diffraction and by an x-ray diffraction method; and (3) …
-
The Cr₃O-type compound in the niobium-rhodium-silicon ternary system
… compacts of high-purity powders. Both x-ray diffractometer and camera techniques were used to analyze the resulting structures. No measurable amount of silicon was found to substitute for rhodium in the Nb₃Rh structure. The 75 percent niobium-25 atomic percent silicon composition contains …
-
A Study of the Cooperative Jahn-Teller Transition in Some Rare Earth Arsenates Using X-ray Diffraction
<p>A low temperature single crystal X-ray diffractometer has been designed and constructed. This has been used to determine the crystal structure of dysprosium arsenate and terbium arsenate at 6ºK. These structures are compared with those found at room temperature. This comparison is used to gain …
-
Cyclic and Isothermal Oxidation Resistance of ASPS Thermal Barrier Coating Systems
… a scanning electron microscope (SEM) and an X-Ray diffractometer. Cr2O3 and spinels (CS) were detected within some of the TBC samples. The growth of spinels highly depended upon coating’s accessibility to oxygen and test duration. Severe outward elemental diffusion and coefficient of thermal …
-
simulation and experiments towards ferroelectric-gate heterojunction field effect transistors
… quality of PZT thin films were measured by X-ray diffractometer and their ferroelectric properties were characterized based on hysteresis loop measurement. Finally, simulation confirms that PZT/AlGaN/GaN ferroelectric gate HFETs exhibit hysteretic I-V characteristics. Counterclockwise …
-
Simulation and experiments towards ferroelectric-gate field effect transistors
… quality of PZT thin films were measured by X-ray diffractometer and their ferroelectric properties were characterized based on hysteresis loop measurement. Finally, simulation confirms that PZT/AlGaN/GaN ferroelectric gate HFETs exhibit hysteretic I-V characteristics. Counterclockwise …
-
The stabilization of flue gas desulfurization sludge by addition of lime and fly ash
… minerals in the treated sludge was detected by X-ray diffractometer. The scanning electron microscope was used to observe the morphology of the treated waste material.</p><p>The increase in shear strength of the treated sludge in relation to the curing time shows the possibility of using lime and …
-
Synthesis and characterization of lanthanide doped nanophosphors
… investigated by thermogravimetry (TG), X-ray diffractometer (XRD), X-ray photoelectron spectroscopy (XPS), scanning electronic microscopy (SEM), transmission electronic microscopy (TEM), and photoluminescence instruments (PL). Meanwhile, we investigated the effect of different factors such …
-
Europiu legiruotų natrio ir kalio aliuminio germanatų liuminescencijos bei kristalinės struktūros tyrimas /
… Synthesized powders were examined using X-ray diffractometer. Luminescent properties of the samples were also measured. Using X-ray diffraction data, Rietveld refinement was performed. X-ray diffraction analysis showed that europium-doped NaAlGeO4 was single-phased. Meanwhile, using …
-
A Mechanically Alloyed Titanium Aluminide for Use in a Total Artificial Hip
… Microscope, Scanning Electron Microscope, and X-Ray Diffractometer. The data will be utilized in future work to optimize values of milling parameters to achieve amorphization or produce microcrystallites and fine crystal structures.
-
X-ray Debye temperatures of solid neon
Measurements of integrated intensities of x-ray Bragg reflections have been made as a function of temperature on large grains of two solid neon specimens. These data have been interpreted in terms of two Debye characteristic temperatures, ~I by the ,method suggested by Nicklow and Young, and eM by …
-
X-ray study of III-Nitride epitaxial layers
… layers was obtained using a high resolution X-ray diffractometer (XRD). Methods discussed earlier in the thesis were employed on the data to analyze critical structural information of the thin GaN films, with an ultimate aim of improving their electrical, structural, thermal and optical …