Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"X-ray fluorescence computed tomography"”.

  1. A feasibility evaluation of x-ray fluorescence emission tomography and x-ray luminescence tomography for real-time assessment of photodynamic therapy

    … Therapy (PDT) has found use in a wide-array of clinical applications such as in cancer and acne treatment. Photodynamic therapy, uses a photosensitive compound activated by a specific wavelength photon to produce cytotoxic oxygen species (either in free radical form or in singlet form). …

    uiuc Repository record for A feasibility evaluation of x-ray fluorescence emission tomography and x-ray luminescence tomography for real-time assessment of photodynamic therapy (opens in a new tab)

  2. Effect of source x-ray energy spectra on the detection of fluorescence photons from gold nanoparticles

    X-ray fluorescence is a well-understood phenomenon in which irradiation of certain materials, such as gold, with x-rays causes the emission of secondary x-rays with characteristic energies. By performing computed tomography using these fluorescence x-rays, the material of interest can be imaged …

    gatech Repository record for Effect of source x-ray energy spectra on the detection of fluorescence photons from gold nanoparticles (opens in a new tab)

  3. Development and validation of a theoretical model for optimizing signal-to-noise ratio in x-ray fluorescence imaging

    There has been a growing interest in benchtop X-ray Fluorescence Computed Tomography (XFCT) due to its potential to non-invasively image non-radioactive targets at greater depths than optical techniques. However, this modality suffers from limited sensitivity due to the high scattering background …

    uiuc Repository record for Development and validation of a theoretical model for optimizing signal-to-noise ratio in x-ray fluorescence imaging (opens in a new tab)

  4. Contrast agent imaging using an optimized table-top x-ray fluorescence and photon-counting computed tomography imaging system

    … dose. Two such imaging techniques include x-ray fluorescence computed tomography (XFCT) and photon-counting CT (PCCT). XFCT combines the principles of CT with x-ray fluorescence by detecting fluorescent x-rays from contrast agents at various projections to reconstruct contrast agent maps. …

    uvic Repository record for Contrast agent imaging using an optimized table-top x-ray fluorescence and photon-counting computed tomography imaging system (opens in a new tab)

  5. Surface Functionalized Organic/Inorganic Colloids: Imaging and Spectroscopy with X-ray and Optical Excitation

    … However, the body suffers from intense auto-fluorescence, so one way to improve imaging agents to combat the auto-fluorescence issue is to create a system that is fluorescence activatable; the activation must occur when the system is only in the intended environment. Additionally, intense …

    clemson Repository record for Surface Functionalized Organic/Inorganic Colloids: Imaging and Spectroscopy with X-ray and Optical Excitation (opens in a new tab)

  6. Development of dosimetry and imaging techniques for pre-clinical studies of gold nanoparticle-aided radiation therapy

    … by an external kilo-voltage source, the fluorescence emitted by the gold atoms would allow one to localize and quantify the GNP concentration. This work has two main aims: to quantify the GNP-mediated dose enhancement during GNRT on a nanometer scale, and to develop a refined imaging …

    gatech Repository record for Development of dosimetry and imaging techniques for pre-clinical studies of gold nanoparticle-aided radiation therapy (opens in a new tab)