Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"X-ray generator"”.

  1. Fabrication Process for Carbon Nanotube Based Field Emission X-ray Generator Cathodes

    Carbon nanotube (CNT) field emission (FE) X-ray generators utilize CNTs to enhance electron generation. CNTs are grown on the cathode in a conical shape with an aspect ratio of 2:1. This shape is necessary for optimal FE. Field emission is a quantum tunnelling process that is achieved by applying a …

    gatech Repository record for Fabrication Process for Carbon Nanotube Based Field Emission X-ray Generator Cathodes (opens in a new tab)

  2. Operation and characteristics of the Flash X-Ray Generator at the Naval Postgraduate School

    Installation of the Model 112A Pulserad Pulsed X ray Generator at the Naval Postgraduate School Flash X ray Facility was completed in August of 1988. Characterization of the Pulserad 112A is essential to its effective use in future radiation effects study. This study will describe the basic system …

    nps Repository record for Operation and characteristics of the Flash X-Ray Generator at the Naval Postgraduate School (opens in a new tab)

  3. Dose analysis of the Model 112A Pulserad Pulsed X-Ray Generator by ITS/CYLTRAN.

    The radiation output from the NPS Pulserad 112A X—ray Generator has been calculated using the ITS code CYLTRAN. The results of this numerical simulation have been compared to the experimental measurements taken previously. These calculations show that the overall photon energy spectrum is …

    nps Repository record for Dose analysis of the Model 112A Pulserad Pulsed X-Ray Generator by ITS/CYLTRAN. (opens in a new tab)

  4. Instrumentation requirements for TREE Effects Data Collection at the Naval Postgraduate School Flash X-ray facility

    … effects on electronics (TREE) data in a pulsed X ray facility is hampered by severe electrical noise created by the pulse generation process. This thesis presents suitable techniques for data collection and evaluation when using the Pulserad Model 112A pulsed X ray generator installed in the Naval …

    nps Repository record for Instrumentation requirements for TREE Effects Data Collection at the Naval Postgraduate School Flash X-ray facility (opens in a new tab)

  5. Application of the Pyroelectric Effect for X-ray Generation

    Over the 100 years of their use, X-ray generators have proven to be indispensable in a wide array of applications. However, the methods for generating X-rays have not developed significantly, and the inherent size and power draw of existing X-ray generators limit the manufacture of more portable …

    unsw Repository record for Application of the Pyroelectric Effect for X-ray Generation (opens in a new tab)

  6. Contour Collimation Systems to be Used for Murine Irradiation

    … various shapes of interest. A Norelco MG300 X-ray generator at the Texas A&M Nuclear Science Center was used in these tests. The lead collimator had a radial penumbra of 1.2 mm. The clay / lead shot collimator had a radial penumbra of 1.6 mm. The brass collimator had a radial penumbra of 1.75 …

    tamu Repository record for Contour Collimation Systems to be Used for Murine Irradiation (opens in a new tab)

  7. Radiographic imaging of microstructural defects in ceramic tapes

    … was developed utilizing recent advances in x-ray microfocus radiography and image processing to study the effects of ceramic tape casting variables on microstructure development. The system was designed to incorporate several advantages over traditional, ceramic characterization routes: …

    iastate Repository record for Radiographic imaging of microstructural defects in ceramic tapes (opens in a new tab)

  8. Modeling, Analysis, and Control of a Mobile Robot for <i>In Vivo</i> Fluoroscopy of Human Joints during Natural Movements

    … One Cartesian manipulator positions the x-ray generator and the other Cartesian manipulator positions the x-ray imaging device. The robotic fluoroscope is used to x-ray skeletal joints of interest of human subjects performing natural movement activities. In order to collect the data, the …

    utk-theses Repository record for Modeling, Analysis, and Control of a Mobile Robot for <i>In Vivo</i> Fluoroscopy of Human Joints during Natural Movements (opens in a new tab)

  9. An experimental study of structure development during melt spinning of polethylend fiber

    … machine was positioned over a rotating anode x-ray generator to allow direct x-ray diffraction studies on the moving filament. Filament diameter, temperature, and tension were also measured.</p><p>Eight sets of process conditions were examined by obtaining filament diameter, temperature, and …

    utk-theses Repository record for An experimental study of structure development during melt spinning of polethylend fiber (opens in a new tab)

  10. The effects of 50 kilovolt x-rays on the alkali metal borohydrides

    … stimulated a study of the effects of 50 Kvp X-rays on the alkali metal borohydrides to determine the nature of the radiation induced changes such as color center formation and chemical decomposition. Methods were developed to prepare the alkali metal borohydrides in a form suitable for …

    ubc Repository record for The effects of 50 kilovolt x-rays on the alkali metal borohydrides (opens in a new tab) Download PDF for The effects of 50 kilovolt x-rays on the alkali metal borohydrides (opens in a new tab)

  11. Use of a Fourier deconvolution method in particle size determination and use of molecular mechanics in crystal structure determinations

    … electron microscope investigations;X-ray structure determinations of single crystals of compounds I: benzo-(2,3) -4-methyl-thiophene, C[subscript]9H[subscript]10S-Ir( C[subscript]5(CH[subscript]3)[subscript]5], and II: dibenzothiophene, C[subscript]12H[subscript]10S-Ir-( …

    iastate Repository record for Use of a Fourier deconvolution method in particle size determination and use of molecular mechanics in crystal structure determinations (opens in a new tab)

  12. From the lab to the real world : sources of error in UF6 gas enrichment monitoring

    … A transmission spectrum is generated using an x-ray tube and a 'notch' filter. In this dissertation, changes that could occur in the detection efficiency and the transmission errors that could result from variations in pipe-wall thickness will be explored. Additional factors that could contribute …

    unm Repository record for From the lab to the real world : sources of error in UF6 gas enrichment monitoring (opens in a new tab)

  13. The characterisation of NaCl crystal for a reusable radiation dosimeter

    … dose deposition. 10 Gy from a superficial x-ray generator was applied to a NaCl crystal in two patterns – uniform and a strip. Optical stimulation was provided using a 100 mW, 488 nm laser, and the emitted signal, characteristic to OSL, was detected in compliance with the deposited dose …

    adelaide Repository record for The characterisation of NaCl crystal for a reusable radiation dosimeter (opens in a new tab)

  14. Propuesta de Implementación de un sistema automático IoT para controlar parámetros de un generador de rayos X convencional mediante Node Red y PLC S7-1200

    … con la finalidad de controlar un Generador de Rayos X mediante la regulación de kilo voltaje, mili amperaje y tiempo de exposición. Los datos mencionados se conectarán a una interfaz de manera remota, para controlar las variables del generador de rayos. Asimismo, se visualiza en tiempo real el …

    upc-peru Repository record for Propuesta de Implementación de un sistema automático IoT para controlar parámetros de un generador de rayos X convencional mediante Node Red y PLC S7-1200 (opens in a new tab)

  15. SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS

    … In this regard, protection measures around an X-ray generator are different from those necessary to protect people and the environment around a radioisotope, which spontaneously emits radiation, alpha, beta, gamma, or neutron, until it decays to a stable element. As great issues of protection …

    liege Repository record for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab) Download PDF for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab)

  16. Design přenosného veterinárního rentgenového přístroje

    Tato diplomová práce se zabývá designem produktové řady přenosného veterinárního rentgenového přístroje. Práce zkoumá možnosti využití parametrizace při návrhu produktů, které tvoří tzv. produktovou rodinu. Podstata práce spočívá v návrhu parametrizačního skriptu, jenž umožňuje generování …

    brno-tech Repository record for Design přenosného veterinárního rentgenového přístroje (opens in a new tab)

  17. Contribution to the search for solar axions in the CAST experiment

    … variable energy calibration system based on an X-ray beam line built at the Max-Planck-Institut für extraterrestrische Physik/Garching (MPE). The purpose of this work is to calibrate for the first time the present and future CAST detectors, in a number of energies and test the efficiency of the …

    greece Repository record for Contribution to the search for solar axions in the CAST experiment (opens in a new tab)