Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"X-ray pulse"”.

  1. X-ray pulse considerations and electron flow in high voltage vacuum diodes

    … diode. This was accomplished by measuring the x rays produced when electrons strike the anode of the diode. Current measurements taken during the experiment include both the displacement and conduction electron current, so the x-ray signal is the best measure of the conduction current. Knowledge …

    nps Repository record for X-ray pulse considerations and electron flow in high voltage vacuum diodes (opens in a new tab)

  2. Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

    … earth, often utilizing high intensity lasers or pulsed power machines. HED systems offer a view into an extreme form of matter only seen in stellar cores, supernovas and other powerful astrophysical systems. Creating HED systems on Earth offer the possibility, if the physics and technology can be …

    unm Repository record for Cherenkov Gamma Ray Detectors on High-Energy-Density Systems (opens in a new tab)

  3. Studying protein dynamics with X-ray free-electron lasers: Opportunities & Limitations

    … of serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) has attracted a great deal of attention by enabling time-resolved (TR) experiments at atomic spatial and femtosecond temporal resolution, thereby allowing unprecedented insight into protein dynamics. The high …

    fu-berlin Repository record for Studying protein dynamics with X-ray free-electron lasers: Opportunities & Limitations (opens in a new tab)

  4. Efficient and Robust Inference of Neutron Star Parameters From Pulse Profile Modeling

    Modeling of X-ray pulse profiles from millisecond pulsars offers a promising method of inferring the mass-to-radius ratios of neutron stars. Recent observations with NICER resulted in measurements of radii for two neutron stars using this technique. In this dissertation, I explore correlations …

    arizona-thes Repository record for Efficient and Robust Inference of Neutron Star Parameters From Pulse Profile Modeling (opens in a new tab)

  5. Opacity and saturable absorption in solid-density plasmas generated by an x-ray free-electron-laser

    … light-sources has opened up new regimes in x-ray–matter interactions. A billion times spectrally brighter than the preceding x-ray sources, free-electron-lasers (FELs) can deposit large amounts of energy into a system in less than 100 fs. Since the absorption of x-rays is reasonably well …

    oxford Repository record for Opacity and saturable absorption in solid-density plasmas generated by an x-ray free-electron-laser (opens in a new tab)

  6. Search for very high energy gamma ray emission from Hercules X-1

    Data from the Haleakala Gamma-ray Observatory taken during 1987 and 1989 is searched for the presence of TeV Gamma-rays from r he direction of Hercules X-1. These two data sets were compiled on two different instruments: the first in operation from 1985 through the end of 1987 and the second, …

    hawaii Repository record for Search for very high energy gamma ray emission from Hercules X-1 (opens in a new tab)

  7. Photoproduction of positive pions near threshold in hydrogen

    … a 1410 hydrogen bubble chamber was used in an X-ray beam with Emax = 230 MeV. Meson tracks could be observed from their origins in the photon beam. Only those events were used in which the '1T+ stopped and decayed in the visible region of the chamber. To suppress electron background, the X-ray …

    uiuc Repository record for Photoproduction of positive pions near threshold in hydrogen (opens in a new tab)

  8. Design, Fabrication and Characterization of a Unipolar Charge Sensing Amorphous Selenium X-ray Detector

    … photoconductor that has been widely used in X-ray imaging applications. Due to its high spatial resolution A-Se plays an important role in breast cancer screening and diagnostics, allowing for the detection of small and subtle lesions. However, a-Se has poor collection efficiency due to low …

    waterloo Repository record for Design, Fabrication and Characterization of a Unipolar Charge Sensing Amorphous Selenium X-ray Detector (opens in a new tab)

  9. Dipole photonic resonators and analogs of matter

    … particle separation, emittance exchange, X-ray pulse compression, temporal beam diagnostics, and crab crossing in colliders. However, conventional deflecting cavities suffer from beam degrading parasitic modes that are also confined within these cavities. Several mode damping/coupling …

    lancaster Download PDF for Dipole photonic resonators and analogs of matter (opens in a new tab)

  10. Kinetic Modeling of Ultraintense X-ray Laser-Matter Interactions

    Although hard-x-ray free-electron lasers (XFELs) have only existed since 2009 when the Linac Coherent Light Source (LCLS) at Stanford created its first laser pulse, their unique capabilities have already had a profound impact on the physical, chemical, and biological sciences. The LCLS can produce …

    unr Repository record for Kinetic Modeling of Ultraintense X-ray Laser-Matter Interactions (opens in a new tab)

  11. Field-Resolved Metrology for Attosecond Timing

    Ultrashort pulses of light have opened new frontiers in both fundamental science and applied technology. The short duration and large bandwidth of these pulses has enabled time-resolved spectroscopy of atomic and molecular dynamics at their natural timescales, allowing direct observation of …

    ucf Repository record for Field-Resolved Metrology for Attosecond Timing (opens in a new tab)

  12. Engineered linear and nonlinear optical properties of metal-dielectric thin-film structures for ultrafast optical applications

    … controls of high peak-power optical signal pulses. Finally, the NLO device technology is integrated into a novel ultrafast all-optical shutter, which allows temporal opening windows (the time shutter remains open) as short as a few ps. Ultrafast all-optical shutter potentially can temporally …

    gatech Repository record for Engineered linear and nonlinear optical properties of metal-dielectric thin-film structures for ultrafast optical applications (opens in a new tab)

  13. Statistics In Diffractive Imaging

    … facility when a bright, coherent, ultrafast X-ray pulse intercepted individual particles of random, unmeasured orientations. This experimental demonstration of cryptotomography extended the Expansion-Maximization-Compression (EMC) framework to accommodate unmeasured fluctuations in photon …

    cornell Repository record for Statistics In Diffractive Imaging (opens in a new tab)

  14. Characterising the photodissociation dynamics of few-atom systems via X-ray Coulomb explosion imaging

    … and dissociation is initiated via an ultraviolet pulse, with either an infrared or X-ray pulse initiating the Coulomb explosion.</p> <p>CH<sub>2</sub>BrI is used to show that comparison of the experimental data to that predicted by a classical over-the-barrier model can determine that at 200 nm …

    oxford Repository record for Characterising the photodissociation dynamics of few-atom systems via X-ray Coulomb explosion imaging (opens in a new tab)

  15. Time-Resolved X-ray Diffraction Studies of Laser-Induced Dynamics in Solids

    X-ray diffraction is an invaluable tool in the field of structural dynamics. In the work described in this thesis, time-resolved X-ray diffraction experiments were carried out to investigate ultrafast lattice dynamics. Ultrashort laser pulses were used to induce non-thermal melting and …

    lund Repository record for Time-Resolved X-ray Diffraction Studies of Laser-Induced Dynamics in Solids (opens in a new tab) Download PDF for Time-Resolved X-ray Diffraction Studies of Laser-Induced Dynamics in Solids (opens in a new tab)

  16. Design and development of a compact x-ray tube for stationary CT architecture

    … architectures enable sweeping one or more x-ray beams across the imaging field-of-view faster than physically moving a single x-ray source and/or a detector. Hence, these architectures are attractive for the applications in which temporal resolution plays an important role, for example, …

    must-thes Repository record for Design and development of a compact x-ray tube for stationary CT architecture (opens in a new tab)

  17. Scattering of an X-Ray beam on a Surface Acoustic Wave

    … to manipulate spa- tially and temporally an X-ray beam. SAWs have been intensively studied in the last decades, and X-ray diffraction proved to be a useful tool to investigate the propa- gation of a SAW in different materials. A SAW induces a sinusoidal deformation on the substrate surface, …

    fu-berlin Repository record for Scattering of an X-Ray beam on a Surface Acoustic Wave (opens in a new tab)

  18. X-Ray Analog Pixel Array Detector For Single Synchrotron Bunch Time-Resolved Imaging

    Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate pulses. An analog integrating pixel array detector (PAD) with in-pixel storage and temporal resolution of around 100 ns, sufficient to isolate synchrotron x-ray …

    cornell Repository record for X-Ray Analog Pixel Array Detector For Single Synchrotron Bunch Time-Resolved Imaging (opens in a new tab)

  19. Growth and Characterization of Hexagonal Rare-Earth Ferrites (h-RFeO3; R = Sc, Lu, Yb)

    … (h-RFeO 3; R = Sc, Lu, Yb) have been grown using pulsed laser deposition method, and their structural and magnetic properties are investigated. Lattice distortions that accompany the transition from high temperature paraelectric hexagonal phase to low temperature ferroelectric hexagonal phase can …

    nebraska Repository record for Growth and Characterization of Hexagonal Rare-Earth Ferrites (h-RFeO3; R = Sc, Lu, Yb) (opens in a new tab)

  20. Photoproduction of charged pions from deuterium near threshold

    … cross section near threshold. To do this an X=ray beam from the University of Illinois betatron was passed through a 14 inch liquid deuterium bubble chamber. Each X ·-ray pulse (E max :: 230 MeV) contained a total energy of about 106 MeV. l'ne X.""ray beam wa.s hardened by means of a. standard …

    uiuc Repository record for Photoproduction of charged pions from deuterium near threshold (opens in a new tab)

Page 1 of 2